Literature DB >> 25439218

Clinical use of a direct chairside oral scanner: an assessment of accuracy, time, and patient acceptance.

Thorsten Grünheid1, Shawn D McCarthy2, Brent E Larson3.   

Abstract

INTRODUCTION: Chairside oral scanners allow direct digital acquisition of the intraoral situation and can eliminate the need for conventional impressions. In this study, we aimed to assess accuracy, scan time, and patient acceptance of a chairside oral scanner when used for full-arch scans; these are critical factors for acceptance of this technology in the orthodontic setting.
METHODS: Fifteen patients had digital models made from both intraoral scans (Lava COS; 3M ESPE, St Paul, Minn) and alginate impressions. Each procedure was timed, and patient preference was assessed with a survey. In addition, digital models were made from 5 plaster model pairs using the intraoral scanner and an orthodontic model scanner. Model pairs were digitally superimposed, and differences between models were quantified. Accuracy was assessed using the Bland-Altman method. Time differences were tested for statistical significance with the Student t test.
RESULTS: Digital models made using the chairside oral scanner and either impressions or the orthodontic model scanner did not differ significantly. The chair time required to take impressions was significantly shorter than the time required for the intraoral scans. When processing time was included, the time requirement did not differ significantly between methods. Although 73.3% of the patients preferred impressions because they were "easier" or "faster," 26.7% preferred the scan because it was "more comfortable."
CONCLUSIONS: Despite the high accuracy of chairside oral scanners, alginate impressions are still the preferred model acquisition method with respect to chair time and patient acceptance. As digital technology continues to progress, intraoral scanning may become more accepted for use in orthodontics.
Copyright © 2014 American Association of Orthodontists. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 25439218     DOI: 10.1016/j.ajodo.2014.07.023

Source DB:  PubMed          Journal:  Am J Orthod Dentofacial Orthop        ISSN: 0889-5406            Impact factor:   2.650


  44 in total

1.  A new method for the evaluation of the accuracy of full-arch digital impressions in vitro.

Authors:  Jan-Frederik Güth; Daniel Edelhoff; Josef Schweiger; Christine Keul
Journal:  Clin Oral Investig       Date:  2015-10-10       Impact factor: 3.573

2.  Accuracy of full-arch digital impressions: an in vitro and in vivo comparison.

Authors:  Christine Keul; Jan-Frederik Güth
Journal:  Clin Oral Investig       Date:  2019-05-27       Impact factor: 3.573

3.  Multibracket appliance: impression defaults and their reduction by blocking-out  -  a three-dimensional study.

Authors:  Susanne Wriedt; Moritz Foersch; Jan Daniel Muhle; Irene Schmidtmann; Heinrich Wehrbein
Journal:  Clin Oral Investig       Date:  2015-06-24       Impact factor: 3.573

4.  Accuracy and reproducibility of measurements on plaster models and digital models created using an intraoral scanner.

Authors:  Leonardo Tavares Camardella; Hero Breuning; Oswaldo de Vasconcellos Vilella
Journal:  J Orofac Orthop       Date:  2017-01-10       Impact factor: 1.938

5.  Accuracy of stereolithographically printed digital models compared to plaster models.

Authors:  Leonardo Tavares Camardella; Oswaldo V Vilella; Marleen M van Hezel; Karel H Breuning
Journal:  J Orofac Orthop       Date:  2017-03-30       Impact factor: 1.938

6.  A comparison of patient experience, chair-side time, accuracy of dental arch measurements and costs of acquisition of dental models.

Authors:  Olja Glisic; Louise Hoejbjerre; Liselotte Sonnesen
Journal:  Angle Orthod       Date:  2019-07-01       Impact factor: 2.079

7.  Efficiency and Accuracy of Three-Dimensional Models Versus Dental Casts: A Clinical Study.

Authors:  Hakan Yılmaz; Fethiye Çakmak Özlü; Carmen Karadeniz; Ersan İlsay Karadeniz
Journal:  Turk J Orthod       Date:  2019-12-01

8.  An Updated Comparison of Current Impression Techniques Regarding Time, Comfort, Anxiety, and Preference: A Randomized Crossover Trial.

Authors:  Hakan Yilmaz; Fatma Asli Konca; Merve Nur Aydin
Journal:  Turk J Orthod       Date:  2021-12

9.  The Effects of Orthodontic Brackets on the Time and Accuracy of Digital Impression Taking.

Authors:  Hyojin Heo; Minji Kim
Journal:  Int J Environ Res Public Health       Date:  2021-05-16       Impact factor: 3.390

10.  Bias Evaluation of the Accuracy of Two Extraoral Scanners and an Intraoral Scanner Based on ADA Standards.

Authors:  Naiyu Cui; Jiayin Wang; Xingyu Hou; Shixun Sun; Qixuan Huang; Ho-Kyung Lim; HongXin Cai; Qi Jia; Eui-Seok Lee; Heng Bo Jiang
Journal:  Scanning       Date:  2021-06-10       Impact factor: 1.932

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.