Literature DB >> 25437885

Is it safe to implant bioresorbable scaffolds in ostial side-branch lesions? Impact of 'neo-carina' formation on main-branch flow pattern. Longitudinal clinical observations.

Antonios Karanasos1, Yingguang Li2, Shengxian Tu3, Jolanda J Wentzel4, Johan H C Reiber2, Robert-Jan van Geuns1, Evelyn Regar1.   

Abstract

Formation of a 'neo-carina' has been reported after bioresorbable vascular scaffolds (BVS) implantation over side-branches. However, as this 'neo-carina' could protrude into the main-branch, its hemodynamic impact remains unknown. We present two cases of BVS implantation for ostial side-branch lesions, and investigate the flow patterns at follow-up and their potential impact. Computational fluid dynamics analysis was performed, using a 3D mesh created by fusion of 3-dimensional angiogram with optical coherence tomography images. In our first case, mild disturbances were seen when 'neo-carina' did not protrude perpendicularly into the main branch. In the second case, extensive flow re-distribution was observed due to a more pronounced protrusion of the 'neo-carina'. Importantly, these areas of hemodynamic disturbance were observed together with lumen narrowing in a non-stenotic vessel segment. Our case observations highlight the importance of investigating the hemodynamic consequences of BVS implantation in bifurcation lesions and illustrate a novel method to do so in vivo.
Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

Keywords:  Atherosclerosis progression; Bifurcation intervention; Bioresorbable vascular scaffold; Computational fluid dynamics; Optical coherence tomography; Primary percutaneous coronary intervention

Mesh:

Substances:

Year:  2014        PMID: 25437885     DOI: 10.1016/j.atherosclerosis.2014.11.013

Source DB:  PubMed          Journal:  Atherosclerosis        ISSN: 0021-9150            Impact factor:   5.162


  3 in total

1.  Superficial wall stress: the long awaited comprehensive biomechanical parameter to objectify and quantify our intuition.

Authors:  Juan Luis Gutiérrez-Chico
Journal:  Int J Cardiovasc Imaging       Date:  2018-06-06       Impact factor: 2.357

2.  Angiographic and optical coherence tomography insights into bioresorbable scaffold thrombosis: single-center experience.

Authors:  Antonios Karanasos; Nicolas Van Mieghem; Nienke van Ditzhuijzen; Cordula Felix; Joost Daemen; Anouchska Autar; Yoshinobu Onuma; Mie Kurata; Roberto Diletti; Marco Valgimigli; Floris Kauer; Heleen van Beusekom; Peter de Jaegere; Felix Zijlstra; Robert-Jan van Geuns; Evelyn Regar
Journal:  Circ Cardiovasc Interv       Date:  2015-05       Impact factor: 6.546

3.  Branch ostial optimization treatment and optimized provisional t-stenting with polymeric bioresorbable scaffolds: Ex-vivo morphologic and hemodynamic examination.

Authors:  Wei Cai; Lianglong Chen; Linlin Zhang; Sheng Tu; Lin Fan; Zhaoyang Chen; Yukun Luo; Xingchun Zheng
Journal:  Medicine (Baltimore)       Date:  2018-10       Impact factor: 1.817

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.