Literature DB >> 25436867

Electrospray ionization time-of-flight mass spectrum analysis method of polyaluminum chloride flocculants.

Chenghong Feng1, Zhe Bi, Hongxiao Tang.   

Abstract

Electrospray mass spectrometry has been reported as a novel technique for Al species identification, but to date, the working mechanism is not clear and no unanimous method exists for spectrum analysis of traditional Al salt flocculants, let alone for analysis of polyaluminum chloride (PAC) flocculants. Therefore, this paper introduces a novel theoretical calculation method to identify Al species from a mass spectrum, based on deducing changes in m/z (mass-to-charge ratio) and molecular formulas of oligomers in five typical PAC flocculants. The use of reference chemical species was specially proposed in the method to guarantee the uniqueness of the assigned species. The charge and mass reduction of the Al cluster was found to proceed by hydrolysis, gasification, and change of hydroxyl on the oxy bridge. The novel method was validated both qualitatively and quantitatively by comparing the results to those obtained with the (27)Al NMR spectrometry.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 25436867     DOI: 10.1021/es503681p

Source DB:  PubMed          Journal:  Environ Sci Technol        ISSN: 0013-936X            Impact factor:   9.028


  1 in total

Review 1.  Recent Approaches for Chemical Speciation and Analysis by Electrospray Ionization (ESI) Mass Spectrometry.

Authors:  Serena Indelicato; David Bongiorno; Leopoldo Ceraulo
Journal:  Front Chem       Date:  2021-01-20       Impact factor: 5.221