Effects of pressure on the shear modulus, mass and thickness of the perfused porcine kidney.

C Helfenstein1, J-L Gennisson2, M Tanter2, P Beillas3.   

Abstract

Eleven fresh ex vivo porcine kidneys were perfused in the artery, vein and ureter with degassed Dulbecco׳s Modified Eagle Medium (DMEM). The effect of perfusion pressure was evaluated using ten different pressures combinations. The shear modulus of the tissues was estimated during perfusion using shear wave elastography. The organ weight change was measured by a digital scale and cameras were used to follow the changes of the dimensions after each pressure combination. The effect of perfusion on the weight and the thickness was non-reversible, whereas the effect on the shear modulus was reversible. Pressure was found to increase the average shear modulus in the cortex by as much as 73%. A pressure of 80 mmHg was needed to observe tissues shear modulus in the same range as in vivo tests (Gcortex=9.1 kPa, Gmedulla=8.5 kPa ex vivo versus Gcortex=9.1 kPa, Gmedulla=8.7 kPa in vivo in Gennisson et al., 2012).
Copyright © 2014 Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Elastography; Kidney; Pressure; Shear modulus

Mesh:

Year:  2014        PMID: 25435383     DOI: 10.1016/j.jbiomech.2014.11.011

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  4 in total

1.  Analyzing acoustoelastic effect of shear wave elastography data for perfused and hydrated soft tissues using a macromolecular network inspired model.

Authors:  D Rosen; J Jiang
Journal:  J Biomech       Date:  2019-09-30       Impact factor: 2.712

2.  On the Challenges Associated with Obtaining Reproducible Measurements Using SWEI in the Median Nerve.

Authors:  Anna E Knight; Samantha L Lipman; Thammathida Ketsiri; Lisa D Hobson-Webb; Kathryn R Nightingale
Journal:  Ultrasound Med Biol       Date:  2020-02-11       Impact factor: 2.998

Review 3.  Novel Uses of Ultrasound to Assess Kidney Mechanical Properties.

Authors:  Matthew W Urban; Andrew D Rule; Thomas D Atwell; Shigao Chen
Journal:  Kidney360       Date:  2021-07-01

4.  Magnetic resonance elastography-derived stiffness of the kidneys and its correlation with water perfusion.

Authors:  Deep Gandhi; Prateek Kalra; Brian Raterman; Xiaokui Mo; Huiming Dong; Arunark Kolipaka
Journal:  NMR Biomed       Date:  2019-12-30       Impact factor: 4.044

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.