Literature DB >> 25434593

Intravoxel incoherent motion diffusion-weighted MR imaging of gliomas: efficacy in preoperative grading.

Yu-Chuan Hu1, Lin-Feng Yan1, Lang Wu2, Pang Du1, Bao-Ying Chen1, Liang Wang3, Shu-Mei Wang4, Yu Han1, Qiang Tian1, Ying Yu1, Tian-Yong Xu5, Wen Wang6, Guang-Bin Cui1.   

Abstract

The preoperative grading of gliomas, which is critical for guiding therapeutic strategies, remains unsatisfactory. We aimed to retrospectively assess the efficacy of intravoxel incoherent motion (IVIM) diffusion-weighted imaging (DWI) in the grading of gliomas. Forty-two newly diagnosed glioma patients underwent conventional MR imaging, DWI, and contrast-enhanced MR imaging. Parameters of apparent diffusion coefficient (ADC), slow diffusion coefficient (D), fast diffusion coefficient (D*), and fraction of fast ADC (f) were generated. They were tested for differences between low- and high-grade gliomas based on one-way ANOVA. Receiver-operating characteristic (ROC) analyses were conducted to determine the optimal thresholds as well as the sensitivity and specificity for grading. ADC, D, and f were higher in the low-grade gliomas, whereas D* tended to be lower (all P<0.05). The AUC, sensitivity, specificity and the cutoff value, respectively, for differentiating low- from high-grade gliomas for ADC, D and f, and differentiating high- from low-grade gliomas for D* were as follows: ADC, 0.926, 100%, 82.8%, and 0.7 × 10(-3) mm(2)/sec; D, 0.942, 92.3%, 86.2%, and 0.623 × 10(-3) mm(2)/sec; f, 0.902, 92.3%, 86.2%, and 35.3%; D*, 0.798, 79.3%, 84.6%, and 0.303 × 10(-3) mm(2)/sec. The IVIM DWI demonstrates efficacy in differentiating the low- from high-grade gliomas.

Entities:  

Mesh:

Year:  2014        PMID: 25434593      PMCID: PMC4248278          DOI: 10.1038/srep07208

Source DB:  PubMed          Journal:  Sci Rep        ISSN: 2045-2322            Impact factor:   4.379


Glioma remains the most common primary malignant brain tumor worldwide1. Glioma is classified into 4 grades, with worse prognosis for more advanced grades2. Previous studies have suggested that different therapeutic strategies should be applied for gliomas at different grades. For example, surgical resection is suggested to be the best approach for low-grade gliomas34, whereas adjuvant chemotherapy and radiotherapy after resection are shown to produce benefits for high-grade glioma patients56. Glioma grading before the operation is therefore of important clinical significance for guiding the grade-dependent therapeutic strategy. Magnetic resonance imaging (MRI) has played important roles in preoperative grading and optimizing therapies7. However, current grading of gliomas with conventional MRI remains unsatisfactory. As an improved MRI technique, diffusion-weighted imaging (DWI) is considered the most sensitive for early pathological changes and therefore can potentially be useful in evaluating the features of gliomas78. To overcome a limitation of DWI, which is that perfusion can substantially confound diffusion measurements because of the incoherent motion of blood, intravoxel incoherent motion (IVIM) based on DWI is proposed910. Although the IVIM MRI technique has been suggested to be useful in the diagnosis and deferential diagnosis of salivary gland, pancreas, renal, liver and breast tumors1112131415, it remains largely unknown whether IVIM MRI can be used to effectively grade glioma and which criteria for parameters should be applied. Although a recent study reported a first attempt to address this issue16, only parameter differences between low- and high-grade gliomas were reported, and there was no information regarding the suitable cutoff values of the suggested differentiating parameters. Therefore, we conducted the current retrospective study to further assess the relationship between parameters (apparent diffusion coefficient (ADC), slow diffusion coefficient (D), fast diffusion coefficient (D*), and fraction of fast ADC (f)) based on IVIM models and the glioma grades and to determine the cutoff values of suggested parameters for differentiating high- from low-grade gliomas.

Results

The histological diagnosis of excised tumors from the 42 patients included in this study (Figure 1) demonstrated that 29 patients had high-grade gliomas (12 had WHO grade IV glioblastoma, 13 had WHO grade III anaplastic astrocytoma, 1 had WHO grade III gliomatosis cerebri and 3 had WHO grade III anaplastic oligodendroglioma), and 13 had low-grade gliomas (6 had WHO grade II astrocytoma and 7 had WHO grade II oligodendroglioma). The descriptive statistics of the IVIM parameters (ADC, D, D* and f) in the tumor sites and healthy white matter sites between patients with low- and high-grade gliomas are shown in Table 1 and Table 2, respectively. In healthy white matter sites between patients with low- and high-grade gliomas, these 4 parameters demonstrated comparable results with no significant differences (P>0.05) (Table 2): the ADC mean value was 0.551 × 10−3 mm2/sec in low-grade (WHO grade II) gliomas and 0.534 × 10−3 mm2/sec in high-grade (WHO grade III-IV) gliomas (P = 0.142); the mean value of D was 0.441 × 10−3 mm2/sec in low-grade gliomas and 0.424 × 10−3 mm2/sec in high-grade gliomas (P = 0.157); the mean value of f was 0.300 in low-grade gliomas and 0.294 in high-grade gliomas (P = 0.576); and the mean value of D* was 2.310 × 10−3 mm2/sec in low-grade gliomas and 2.355 × 10−3 mm2/sec in high-grade gliomas (P = 0.157). By contrast, in tumor sites between patients with low- and high-grade gliomas, we detected significant differences for all 4 parameters (Table 1). Specifically, the mean value of ADC was higher for the low-grade gliomas compared with high-grade gliomas (0.906 × 10−3 vs 0.618 × 10−3 mm2/sec, P<0.001); higher mean values of D and f were also observed for the low-grade gliomas (0.756 × 10−3 vs 0.506 × 10−3 mm2/sec, P<0.001; 0.477 vs 0.290, P<0.001, respectively), whereas for D*, the mean value was higher for the high-grade patients than the low-grade patients (2.706 × 10−3 vs 2.150 × 10−3 mm2/sec, P = 0.013). The box plots of these parameters in the 2 categories of gliomas clearly demonstrate these patterns (Figure 2).
Figure 1

Flow diagram for the patient selection process.

Table 1

IVIM-derived parameters in the tumor sites in low- and high-grade gliomas

 LGGHGGP-value*
ADC (×10−3 mm2 /sec)0.906 ± 0.1100.618 ± 0.1420.000
D (×10−3 mm2 /sec)0.756 ± 0.1100.506 ± 0.1170.000
D* (×10−3 mm2 /sec)2.150 ± 0.4232.706 ± 0.8520.013
f0.477 ± 0.1300.290 ± 0.0960.000

Note: LGG denotes low-grade gliomas, HGG denotes high-grade gliomas.

*The P values were the comparison of the parameters between low- and high- grade gliomas.

Table 2

IVIM-derived parameters in the normal white matte between low- and high-grade gliomas

 LGGHGGP-value*
ADC (×10−3 mm2 /sec)0.551 ± 0.0230.534 ± 0.0380.142
D (×10−3 mm2 /sec)0.441 ± 0.0260.424 ± 0.0390.157
D* (×10−3 mm2 /sec)2.310 ± 0.3512.355 ± 0.2600.647
f0.300 ± 0.0320.294 ± 0.0270.576

Note: LGG denotes low-grade gliomas, HGG denotes high-grade gliomas.

*The P values were the comparison of the parameters in normal white matter between low- and high grade gliomas.

Figure 2

Box plots for values of ADC, D, D*, and f in high- and low-grade gliomas.

Figure 3 demonstrates the ROC curves for the grading performances of the four parameters (ADC, D, f, and D*), specifically, differentiating the low- from high- grade gliomas for ADC, D, and f, and differentiating the high- from low-grade gliomas for D*. The values of AUC, sensitivity, specificity, as well as the suggestive cutoff values for each parameter are shown in Table 3. Briefly, with an AUC of 0.926, the ADC parameter had 100% sensitivity and 82.8% specificity for identifying low-grade gliomas at the cutoff value of 0.7 × 10−3 mm2/sec. The AUC for parameter D was 0.942, and 92.3% sensitivity and 86.2% specificity was achieved for identifying low-grade gliomas at the cutoff value of 0.623 × 10−3 mm2/sec. For parameter f, with an AUC of 0.902, 92.3% sensitivity and 86.2% specificity was achieved at the cutoff value of 35.3%. Additionally, D* achieved an AUC of 0.798, and the cutoff value of 2.303 × 10−3 mm2/sec exhibited a sensitivity of 79.3% and a specificity of 84.6% for identifying high-grade gliomas.
Figure 3

ROC curve for differentiating the performance of the four parameters (ADC, D, D*, and f), specifically, differentiating the low- from high-grade gliomas for ADC, D and f, and identifying the high- from low- grade gliomas for D*.

Table 3

ROC curve

 AUCP valueSensitivity (%)Specificity (%)Cutoff value
ADC (×10−3 mm2 /sec).926.000100.082.8.700
D (×10−3 mm2 /sec).942.00092.386.2.623
D* (×10−3 mm2 /sec).798.00279.384.62.303
f (%).902.00092.386.2.353

Discussion

In the current study, we evaluated whether the IVIM MRI could be used preoperatively to grade gliomas. We detected significant differences in parameters ADC, D, D*, and f between low- and high-grade gliomas. We also determined the most appropriate cutoff values for each suggested parameter, which could potentially be used in clinical practice regarding preoperatively grading gliomas, if validated in larger studies. The ADC value can potentially reveal the differences in cellularity and nuclear atypia of gliomas17. Theoretically, high cellularity in advanced gliomas may impede free water diffusion and thus lead to a decreased ADC value. In a study by Higano et al., the minimum ADC varied significantly between WHO grade III ((1.06 ± 0.21) × 10−3 mm2/sec) and WHO grade IV gliomas ((0.83 ± 0.14) × 10−3 mm2/sec)18. Another study also revealed a significantly higher frequency of low ADC values in high- compared with low-grade gliomas19. In addition, parameter D was shown to be inversely correlated with cell density17. In the current study, we found that the ADC and D values were significantly lower in high-grade gliomas compared with low-grade gliomas (P<0.001), which confirmed previous findings20. Interestingly, our findings are inconsistent with another recently published study, in which ADC and D did not demonstrate significant differences between low- and high-grade gliomas16. One possible explanation for the deviation can be that different b values were used. Research has indicated that the accuracy of IVIM parameter calculation is affected by b values920. In the current study, 13 b values were used, including 5 ranging from 0 to 200 sec/mm2 and 8 ranging from 300 to 3500 sec/mm2, which is markedly different from the previous study in which 11 b values ranging from 0 to 200 sec/mm2 and 3 ranging from 700 to 1300 sec/mm2 were used16. Another possible explanation is the different definition of ROI applied in these two studies. In the previous study, the ROI was placed on the tumor area with the largest diameter encompassing as much solid tumor area as possible16. However, because of the heterogeneous inner structure of glioma, especially anaplastic glioma and glioblastoma, we argue the most malignant portion of tumor may be more appropriate for calculating the parameters21. In the current study, ROI included the tumor solid parts with the highest signal intensity on DW imaging (b = 1000 sec/mm2) and the relatively low ADC values of the corresponding areas on ADC map, based on the rationale of using the minimum ADC value measurements to sample the highest tumor cell attenuation or the most proliferative portions of the tumor. We noted that another study used a similar method of determining ROI and suggested that measuring the minimum ADC could provide diagnostic information for the preoperative grading of supratentorial astrocytomas21. The degree of neovascularization is critical in assessing tumor grade and malignancy22. Malignant gliomas are characterized by increased angiogenesis, which is a marker of the histological grading system23. The parameter D* from the IVIM model is influenced by microvessel density (MVD) within the tumor, which is associated with an average length of capillaries and blood flow velocities9. In the current study, we demonstrated that D* was significantly higher in high-grade than in low-grade gliomas, which is consistent with the MVD theory9. Previous studies have suggested that the relative cerebral blood volume (rCBV) value is correlated with the grade and vascularity in gliomas2425. Usually, low-grade gliomas show no increase in tumor rCBV, whereas high-grade gliomas demonstrate high rCBV that in some cases even extends outside the contrast-enhancing portions of the tumor26. The parameter f represents the fraction of the fast diffusion component and is affected by the abundance of capillaries. In this analysis, we detected that f was significantly lower in high-grade gliomas, which is inconsistent with findings in several other studies1627. Several potential reasons may explain this difference. The instruments used in these studies are not consistent, and different b values were used. Because the lower b-values were more important for calculating pseudodiffusion28, the b value might influence the accuracy of the f value measurements. Additionally, as discussed above, in our study, we determined ROI to include the tumor solid parts with the highest signal intensity on DW imaging, which is in contrast to other studies. The highest cellularity density and the nuclear cytoplasmic ratio as well as relatively fewer mesenchymal components are revealed in anaplastic gliomas and glioblastomas23, which can potentially explain the findings involving f1627. In the current study, we also assessed the diagnostic efficacy of IVIM parameters in differentiating glioma grades. Although the optimal b values remain unknown, we demonstrated that ADC, D, D*, and f could achieve relatively high AUC in grading gliomas preoperatively. It was indicated that a cutoff value of 0.7 × 10−3 mm2/sec for ADC, 0.623 × 10−3 mm2/sec for D, and 35.3% for f could produce relatively satisfactory sensitivity and specificity for identifying low- from high-grade gliomas. The combined evaluation of these three values may provide a better estimation for the preoperative glioma grading. One important consideration of using the IVIM technique based on DW MRI is obtaining reliable and repeatable data from patients. In our study, to ensure data accuracy, we obtained data from healthy white matter sites in patients. Analysis revealed no significant difference for each parameter between low- and high-grade gliomas (as shown in table 2), which suggested the reliability of the obtained data in our study. Several concerns should be considered in interpreting our findings. First, hand-drawn ROIs were used in the current study. Because the nests of tumor cells tend to be heterogeneously distributed, a measurement of ADC values by manual drawing of the ROIs on the DWI (trace image) may introduce sampling bias. Second, the b values ranging from 0 to 200 sec/mm2 are limited in our study, which may influence the accurate assessment of f and D*. However, the optimal number of lower b-values for IVIM remains undetermined, and further research is warranted to clarify this issue. To the best of our knowledge, this is the largest study to date that evaluated IVIM modelling based on DW MRI in differentiating low- from high-grade gliomas. Our study clearly suggests that several parameters from IVIM modelling, including ADC, D, D*, and f, could potentially serve as non-invasive predictors for the preoperative grading of gliomas.

Methods

Participants

This single-center retrospective study was approved by the Ethics Committee of Tangdu Hospital of the Fourth Military Medical University, and informed consents were obtained from all participants. This study was conducted in accordance with the Declaration of Helsinki. Between September 2013 and May 2014, 104 consecutive patients with suspected intracranial occupying lesions underwent routine MRI, IVIM DWI, as well as contrast-enhanced MRI of the brain. Of these, 62 subjects were excluded as follows: 1, the histopathological grades were not available because operations were not performed (n = 31); 2, corticosteroid therapy was administered before MR imaging with IVIM-DWI (n = 7); 3, the lesion was determined not to be a glioma based on pathological evaluation (n = 21); 4, the image quality was unsatisfactory (n = 2); and 5, a pure cystic glioma was observed (n = 1). The final study population contained 42 patients (25 men and 17 women; mean age, 47 years; age range, 19–77 years) with newly diagnosed glioma.

Brain MR imaging

The whole brain MRI examinations were performed on a 3.0-T MRI system (MR750, GE Healthcare, Milwaukee, WI, USA) with a standard receive-only head coil. Conventional MRI, DWI with 13 b-values (0–3500 s/mm2) and contrast-enhanced MRI were performed in regular sequence during the same examination. Conventional MRI sequences included T1-weighted spin echo in the transverse plane (TR/TE, 1,750 ms/24 ms; matrix size, 256 × 256; field of view, 24 × 24 cm; number of excitation, 1; slice thickness, 5 mm; gap, 1.5 mm), T2-weighted fast spin echo in the transverse planes (TR/TE, 4,247 ms/93 ms; matrix size, 512 × 512; field of view, 24 × 24 cm; number of excitation, 1; slice thickness, 5 mm; gap, 1.5 mm) and sagittal planes (TR/TE, 10,639 ms/96 ms; matrix size, 384 × 384; field of view, 24 × 24 cm; number of excitation, 2; slice thickness, 5 mm; gap, 1.0 mm), and fluid-attenuated inversion recovery (FLAIR) in the transverse plane (TR/TE,8,000 ms/165 ms; matrix size, 256 × 256; field of view, 24 cm × 24 cm; number of excitation, 1; slice thickness, 5 mm; gap, 1.5 mm). The IVIM DWI sequence was performed prior to the injection of Gd. Thirteen b values (0, 30, 50, 100, 200, 300, 500, 800, 1000, 1500, 2000, 3000 and 3500 s/mm2) were applied with a single-shot diffusion-weighted spin-echo echo-planar sequence. The lookup table of gradient directions was modified to allow multiple b value measurements in one series. Parallel imaging was used with an acceleration factor of 2. A local shim box covering the whole brain was applied to minimize susceptibility artifacts. In total, 20 axial slices covering the entire brain were obtained with a 24-cm field of view, 5 mm slice thickness, 1.5 mm slice gap, 3,000 ms TR, Minimum TE, 128 × 128 matrix. The total scan time was 5 min and 45 s. Finally, a contrast-enhanced T1-weighted spin echo sequence was performed in the transverse, sagittal, and coronal planes (TR/TE, 1850 ms/24 ms for transverse plane and 1750 ms/24 ms for sagittal and coronal planes; other parameters were the same as conventional MRI) following a bolus injection of 0.1 mmol/kg of gadodiamide injection (Omniscan; GE Healthcare, Co.Cork, Ireland).

IVIM DW MRI analysis

According to IVIM, the relationship between signal variation and b values can be expressed by using Equation (1)9: where S0 and Sb are the signal intensities at a b value of 0 sec/mm2 and each b value other than 0 sec/mm2, respectively; D is the true diffusion coefficient that reflects random motion of intra- and intercellular water molecules (slow component of diffusion); f is the fraction of the diffusion linked to microcirculation, and D* is the diffusion parameter representing incoherent microcirculation within the voxel (perfusion-related diffusion, or fast component of diffusion). Considering that D* is significantly greater than D910, the influence of D* on signal decay can be neglected for b values greater than 200 sec/mm2. Equation (1) can then be simplified, and the estimation of D can be obtained by using only b values greater than 200 sec/mm2, with a simple linear fit equation (2): Hence, for high b values (300, 500, 800, 1000, 1500, 2000, 3000 and 3500 sec/mm2) Sb was first fitted to equation (2) using a linear model, and the true diffusion coefficient D was calculated. The f and D* values were calculated by using a nonlinear regression algorithm based on equation (1). The ADC value was calculated by fitting the b0 image and DWIs at each b value other than 0 sec/mm2 into the conventional ADC equation (Eq. (3))9: Magnetic Resonance Imaging Data Processing and Quantitative Analysis All data were analyzed and processed on a GE ADW4.6 workstation. The mean values of all IVIM parameters were measured independently by two experienced radiologists. First, they reviewed the conventional plain and contrast-enhanced MRI images carefully to determine the solid part of each tumor. Next, the multi-b-value data were analyzed using a MADC program. A freehand ROI was placed to cover as much of the solid part of the tumors as possible; a freehand ROI was placed to include the solid tumor parts with the highest signal intensity on DW image (b = 1000 sec/mm2) and the relatively low ADC values of the corresponding areas on the ADC map to avoid large vessels and hemorrhagic, calcified, cystic and necrotic areas (as shown in Figure 4.a or Figure 5.a). The mean ROI area of the lesions was 135.5 ± 92.7 mm2 (range, 45.0–374.0 mm2). For the contralateral healthy appearing white matter, standardized ROIs (the same size as the ROI of the lesions) were placed. The parameter maps of IVIM were generated automatically by the MADC program (as shown in Figure 4 or Figure 5), and the mean ADC, D, D*, and f values in the ROIs were obtained, respectively.
Figure 4

A case of low-grade glioma.

(a) Axial diffusion-weighted trace image (b = 1000 sec/mm2). (b) The bi-exponential fitting of the diffusion signal decay over a wide-range of b values (up to 3,500). (c) Axial apparent diffusion coefficient (ADC) map. (d) The D map. (e) The f map. (f) The D* map. The DWI shows a mild hyperintense mass (ROI 1) on the right frontal-temporal region in a patient with grade II glioma. On the ADC and D map, the region of tumor is confirmed as higher signal intensity (increased ADC value, encoded in a green–yellow–red color schema) compared to the healthy white matter (ROI 2). The f map demonstrates a higher perfusion fraction region compared to the healthy white matter. The D* map shows a slightly decreased fast-diffusion values in the tumor tissue compared to the healthy white matter.

Figure 5

A case of high-grade glioma.

(a) Axial diffusion-weighted trace image (b = 1000 sec/mm2). (b) The bi-exponential fitting of the diffusion signal decay over a wide-range of b values (up to 3,500). (c) Axial apparent diffusion coefficient (ADC) map. (d) The D map. (e) The f map. (f) The D* map. The DWI shows inhomogeneous signal intensity mass on the left frontal-parietal lobe in a patient with grade IV glioma, with significantly high signal intensity (ROI 1) in tumor. On the ADC and D map, the area of restricted diffusion is confirmed as an isointense lesion (decreased ADC value, encoded in a blue color) compared to the healthy white matter (ROI 2). The f map demonstrates a higher perfusion fraction region compared to the healthy white matter. The D* map shows a slightly decreased fast-diffusion values in the tumor tissue compared to the healthy white matter.

Statistical analysis

Numerical variables were denoted as the mean and standard deviation. Parameters ADC, D, D*, and f in healthy white matter and tumor sites were tested for differences between the low-grade (WHO II) and the high-grade gliomas (WHO III and IV) by using ANOVA. Receiver operating characteristic (ROC) analyses were performed to determine the optimal thresholds for differentiating the low-grade (WHO II) from the high-grade gliomas (WHO III and IV) by ADC, D, D*, and f value. In addition, the sensitivity, specificity, and area under curve (AUC) for identifying low-grade gliomas were calculated in each case, except for D* when high-grade gliomas were differentiated. P <0.05 indicated a statistically significant difference. SPSS17.0 software (SPSS Inc, Chicago, IL, USA) was used for all statistical analyses.

Author Contributions

Y.-C.H., L.-F.Y., L.W., W.W. and G.-B.C. participated in the study design. Y.-C.H., L.-F.Y., P.D., B.-Y.C., L.W., S.-M.W., Y.H., Q.T., Y.Y., T.-Y.X. collected the data; Y.-C.H., L.W. and W.W. analyzed the data; all authors participated in the interpretation of the data; Y.-C.H. and L.W. prepared the first draft of the manuscript; all authors revised and approved the manuscript.
  28 in total

1.  Perfusion measurement in brain gliomas with intravoxel incoherent motion MRI.

Authors:  C Federau; R Meuli; K O'Brien; P Maeder; P Hagmann
Journal:  AJNR Am J Neuroradiol       Date:  2013-08-08       Impact factor: 3.825

2.  Salivary gland tumors: use of intravoxel incoherent motion MR imaging for assessment of diffusion and perfusion for the differentiation of benign from malignant tumors.

Authors:  Misa Sumi; Marc Van Cauteren; Tadateru Sumi; Makoto Obara; Yoko Ichikawa; Takashi Nakamura
Journal:  Radiology       Date:  2012-03-23       Impact factor: 11.105

3.  Separation of diffusion and perfusion in intravoxel incoherent motion MR imaging.

Authors:  D Le Bihan; E Breton; D Lallemand; M L Aubin; J Vignaud; M Laval-Jeantet
Journal:  Radiology       Date:  1988-08       Impact factor: 11.105

4.  Diffusion-weighted intravoxel incoherent motion imaging of renal tumors with histopathologic correlation.

Authors:  Hersh Chandarana; Stella K Kang; Samson Wong; Henry Rusinek; Jeff L Zhang; Shigeki Arizono; William C Huang; Jonathan Melamed; James S Babb; Edgar F Suan; Vivian S Lee; Eric E Sigmund
Journal:  Invest Radiol       Date:  2012-12       Impact factor: 6.016

5.  Gliomas: Histogram analysis of apparent diffusion coefficient maps with standard- or high-b-value diffusion-weighted MR imaging--correlation with tumor grade.

Authors:  Yusuhn Kang; Seung Hong Choi; Young-Jae Kim; Kwang Gi Kim; Chul-Ho Sohn; Ji-Hoon Kim; Tae Jin Yun; Kee-Hyun Chang
Journal:  Radiology       Date:  2011-10-03       Impact factor: 11.105

6.  Differentiation of pancreas carcinoma from healthy pancreatic tissue using multiple b-values: comparison of apparent diffusion coefficient and intravoxel incoherent motion derived parameters.

Authors:  Andreas Lemke; Frederik B Laun; Miriam Klauss; Thomas J Re; Dirk Simon; Stefan Delorme; Lothar R Schad; Bram Stieltjes
Journal:  Invest Radiol       Date:  2009-12       Impact factor: 6.016

7.  Liver cirrhosis: intravoxel incoherent motion MR imaging--pilot study.

Authors:  Alain Luciani; Alexandre Vignaud; Madeleine Cavet; Jeanne Tran Van Nhieu; Ariane Mallat; Lucile Ruel; Alexis Laurent; Jean-François Deux; Pierre Brugieres; Alain Rahmouni
Journal:  Radiology       Date:  2008-12       Impact factor: 11.105

8.  The effect of low b-values on the intravoxel incoherent motion derived pseudodiffusion parameter in liver.

Authors:  Alexander D Cohen; Moira C Schieke; Mark D Hohenwalter; Kathleen M Schmainda
Journal:  Magn Reson Med       Date:  2014-01-29       Impact factor: 4.668

9.  Preoperative grading of presumptive low-grade astrocytomas on MR imaging: diagnostic value of minimum apparent diffusion coefficient.

Authors:  E J Lee; S K Lee; R Agid; J M Bae; A Keller; K Terbrugge
Journal:  AJNR Am J Neuroradiol       Date:  2008-08-21       Impact factor: 3.825

10.  Using relative cerebral blood flow and volume to evaluate the histopathologic grade of cerebral gliomas: preliminary results.

Authors:  Ji Hoon Shin; Ho Kyu Lee; Byung Duk Kwun; Jin-Suh Kim; Weechang Kang; Choong Gon Choi; Dae Chul Suh
Journal:  AJR Am J Roentgenol       Date:  2002-09       Impact factor: 3.959

View more
  39 in total

1.  Temporal evolution of perfusion parameters in brain metastases treated with stereotactic radiosurgery: comparison of intravoxel incoherent motion and dynamic contrast enhanced MRI.

Authors:  Anish Kapadia; Hatef Mehrabian; John Conklin; Sean P Symons; Pejman J Maralani; Greg J Stanisz; Arjun Sahgal; Hany Soliman; Chinthaka C Heyn
Journal:  J Neurooncol       Date:  2017-07-01       Impact factor: 4.130

Review 2.  'Low grade glioma': an update for radiologists.

Authors:  Jennifer Larsen; Steve B Wharton; Fiona McKevitt; Charles Romanowski; Caroline Bridgewater; Hesham Zaki; Nigel Hoggard
Journal:  Br J Radiol       Date:  2016-12-07       Impact factor: 3.039

Review 3.  Advanced imaging techniques in the therapeutic response of transarterial chemoembolization for hepatocellular carcinoma.

Authors:  Ke Yang; Xiao-Ming Zhang; Lin Yang; Hao Xu; Juan Peng
Journal:  World J Gastroenterol       Date:  2016-05-28       Impact factor: 5.742

4.  Differentiating the histologic grades of gliomas preoperatively using amide proton transfer-weighted (APTW) and intravoxel incoherent motion MRI.

Authors:  Tianyu Zou; Hao Yu; Chunxiu Jiang; Xianlong Wang; Shanshan Jiang; Qihong Rui; Yingjie Mei; Jinyuan Zhou; Zhibo Wen
Journal:  NMR Biomed       Date:  2017-11-03       Impact factor: 4.044

5.  Application of intravoxel incoherent motion (IVIM) magnetic resonance imaging in the evaluation of primitive brain tumours.

Authors:  A Catanese; F Malacario; L Cirillo; F Toni; C Zenesini; D Casolino; A Bacci; R Agati
Journal:  Neuroradiol J       Date:  2017-06-23

6.  Non-Gaussian diffusion MR imaging of glioma: comparisons of multiple diffusion parameters and correlation with histologic grade and MIB-1 (Ki-67 labeling) index.

Authors:  Ren Yan; Pang Haopeng; Feng Xiaoyuan; Wu Jinsong; Zhang Jiawen; Yao Chengjun; Qiu Tianming; Xiong Ji; Sheng Mao; Ding Yueyue; Zhang Yong; Luo Jianfeng; Yao Zhenwei
Journal:  Neuroradiology       Date:  2015-10-22       Impact factor: 2.804

Review 7.  Optimal differentiation of high- and low-grade glioma and metastasis: a meta-analysis of perfusion, diffusion, and spectroscopy metrics.

Authors:  Jurgita Usinskiene; Agne Ulyte; Atle Bjørnerud; Jonas Venius; Vasileios K Katsaros; Ryte Rynkeviciene; Simona Letautiene; Darius Norkus; Kestutis Suziedelis; Saulius Rocka; Andrius Usinskas; Eduardas Aleknavicius
Journal:  Neuroradiology       Date:  2016-01-15       Impact factor: 2.804

8.  The diagnostic value of intravoxel incoherent motion imaging in differentiating high-grade from low-grade gliomas: a systematic review and meta-analysis.

Authors:  Hechuan Luo; Ling He; Weiqin Cheng; Sijie Gao
Journal:  Br J Radiol       Date:  2021-05-01       Impact factor: 3.039

9.  Monoexponential, biexponential and stretched exponential models of diffusion weighted magnetic resonance imaging in glioma in relation to histopathologic grade and Ki-67 labeling index using high B values.

Authors:  Nabin Chaudhary; Guiling Zhang; Shihui Li; Wenzhen Zhu
Journal:  Am J Transl Res       Date:  2021-11-15       Impact factor: 4.060

10.  Genetic Variants of PTPN2 Gene in Chinese Children with Type 1 Diabetes Mellitus.

Authors:  Hui Peng; Jiamei Li; Xiaoyun Chen; Xiao Zhou; Weiwei Zhu; Feng Li
Journal:  Med Sci Monit       Date:  2015-09-07
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.