High submuscular placement of urologic prosthetic balloons and reservoirs: 2-year experience and patient-reported outcomes.

Paul H Chung1, Allen F Morey2, Timothy J Tausch1, Jay Simhan1, J Francis Scott1.   

Abstract

OBJECTIVE: To present our updated experience and patient-reported outcomes of high submuscular (HSM) placement of urologic prosthetic balloons and reservoirs (UPBRs).
METHODS: A retrospective review was performed of patients who underwent inflatable penile prosthesis and/or artificial urinary sphincter placement between 2011 and 2013. UPBRs were placed in an HSM location between the transversalis fascia and the rectus abdominis muscle by blunt dissection through the external inguinal ring via a trans-scrotal approach. Patient demographics, perioperative outcomes, and patient-reported outcomes were reviewed.
RESULTS: During the study period, 146 patients received 158 HSM implants: inflatable penile prosthesis reservoirs (n = 93) or artificial urinary sphincter balloons (n = 65). Patients completed a standardized survey at a mean of 3.2 months (range, 1.1-23.4 months) after surgery and were last followed up at a mean of 5.5 months (range, 1.1-28.7 months). Overall, 94% (n = 149) of UPBRs caused no bother, and patients were satisfied with 96% (n = 151) of implants. Patients were unable to palpate 80% (n = 126) of UPBRs and minimally palpate 16% (n = 26). The primary surgeon was unable to palpate 72% (n = 115) of UPBRs and minimally palpate 20% (n = 31). Type of UPBR, body mass index, reservoir volume, and reservoir manufacturer were not associated with patient or surgeon palpability. Of the 158 UPBRs placed, only 2 (1.3%) were revised due to bothersome patient palpability. No bowel, bladder, ureteral, or vascular injuries occurred.
CONCLUSION: HSM placement of UPBR is safe and feasible, well tolerated, and avoids deep retropubic dissection. Patient-reported outcomes support low palpability, low bother, and high patient satisfaction.
Copyright © 2014 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2014        PMID: 25432851     DOI: 10.1016/j.urology.2014.08.029

Source DB:  PubMed          Journal:  Urology        ISSN: 0090-4295            Impact factor:   2.649


  10 in total

Review 1.  A practical overview of considerations for penile prosthesis placement.

Authors:  Landon Trost; Philip Wanzek; George Bailey
Journal:  Nat Rev Urol       Date:  2015-12-01       Impact factor: 14.432

Review 2.  Alternative Reservoir and Balloon Placement in Complex Patients Undergoing Urologic Prostheses.

Authors:  Travis J Pagliara; Daniel W Smith; Boyd R Viers; Allen F Morey
Journal:  Curr Urol Rep       Date:  2018-04-13       Impact factor: 3.092

3.  Longitudinal and Horizontal Load Testing of Inflatable Penile Implant Cylinders of Two Manufacturers: An Ex Vivo Demonstration of Inflated Rigidity.

Authors:  Jason M Scovell; Liehui Ge; Enrique V Barrera; Steven K Wilson; Rafael E Carrion; Tariq S Hakky
Journal:  J Sex Med       Date:  2016-11       Impact factor: 3.802

Review 4.  Reservoir Placement Considerations During Inflatable Penile Prosthesis Surgery.

Authors:  Steven J Hudak
Journal:  Curr Urol Rep       Date:  2019-01-28       Impact factor: 3.092

Review 5.  A Systematic Approach to the Evaluation and Management of the Failed Artificial Urinary Sphincter.

Authors:  Amy D Dobberfuhl; Craig V Comiter
Journal:  Curr Urol Rep       Date:  2017-03       Impact factor: 3.092

Review 6.  Optimizing Outcomes in the Virgin Penile Implant Patient.

Authors:  Charles Welliver
Journal:  Curr Urol Rep       Date:  2019-02-07       Impact factor: 3.092

Review 7.  Preoperative counseling and expectation management for inflatable penile prosthesis implantation.

Authors:  Gopal L Narang; Bradley D Figler; Robert M Coward
Journal:  Transl Androl Urol       Date:  2017-11

Review 8.  Penile prosthesis in the management of erectile dysfunction following cancer therapy.

Authors:  Pranav Dadhich; Mark Hockenberry; E Will Kirby; Larry Lipshultz
Journal:  Transl Androl Urol       Date:  2017-11

Review 9.  Penile prosthesis implant: scientific advances and technological innovations over the last four decades.

Authors:  Eric Chung
Journal:  Transl Androl Urol       Date:  2017-02

10.  Counter incision is a safe and effective method for alternative reservoir placement during inflatable penile prosthesis surgery.

Authors:  Dominic Grimberg; Sabrina Wang; Evan Carlos; Brent Nosé; Shelby Harper; Aaron C Lentz
Journal:  Transl Androl Urol       Date:  2020-12
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.