Literature DB >> 25432538

Set-up verification and 2-dimensional electronic portal imaging device dosimetry during breath hold compared with free breathing in breast cancer radiation therapy.

Patricia J A M Brouwers1, Tim Lustberg2, Jacques H Borger2, Angela A W van Baardwijk2, Jos J Jager2, Lars H P Murrer2, Sebastian M J J G Nijsten2, Bart H Reymen2, Judith G M van Loon2, Liesbeth J Boersma2.   

Abstract

PURPOSE: To compare set-up and 2-dimensional (2D) electronic portal imaging device (EPID) dosimetry data of breast cancer patients treated during voluntary moderately deep inspiration breath hold (vmDIBH) and free breathing (FB). METHODS AND MATERIALS: Set-up data were analyzed for 29 and 51 consecutively treated patients, irradiated during FB and vmDIBH, respectively. Of the 51 vmDIBH patients, the first 25 had undergone an extra trained computed tomography (CT) scan and used an additional "breathing stick" (vmDIBH_trained). The last 26 patients did not use the breathing stick and did not undergo a trained CT (vmDIBH_untrained). The delivered 2D transit dose was measured with EPID in 15 FB and 28 vmDIBH patients and compared with a 2D predicted dose by calculating global gamma values γ using 5% and 5 mm as dose difference and distance-to-agreement criteria, respectively. Measurements with a percentage of pixels with an absolute gamma value > 1 (|γ| > 1) greater than 10% were classified as deviating.
RESULTS: Only small, sub-millimeter differences were seen in the set-up data between the different patient groups. The mean of means, systematic error, and random error ranged from - 0.6 mm to 3.3 mm. The percentage of pixels with |γ| > 1 for all patients was 9.8% (2-25.8). No statistically significant differences were observed between the patient groups. In total, 38% of the gamma images were classified as deviating: 43.6% in vmDIBH_untrained patients compared with 38.0% in vmDIBH_trained patients and 33.3% in FB patients (P > .05).
CONCLUSION: Both set-up and 2D EPID dosimetry data indicate that reproducibility of radiation therapy for patients treated during FB and vmDIBH is similar. Small but not significant differences in 2D EPID dosimetry were observed. Further investigation with 3-dimensional EPID dosimetry is recommended to investigate the clinical relevance of deviant gamma images.

Entities:  

Mesh:

Year:  2015        PMID: 25432538     DOI: 10.1016/j.prro.2014.10.005

Source DB:  PubMed          Journal:  Pract Radiat Oncol        ISSN: 1879-8500


  10 in total

1.  In vivo Portal Imaging Dosimetry Identifies Delivery Errors in Rectal Cancer Radiotherapy on the Belly Board Device.

Authors:  Stefano Peca; Richie Siddhartha Sinha; Derek Wilson Brown; Wendy Lani Smith
Journal:  Technol Cancer Res Treat       Date:  2017-06-06

2.  Development of a deep inspiration breath-hold system for radiotherapy utilizing a laser distance measurer.

Authors:  Christer Andre Jensen; Nils Skottner; Jomar Frengen; Jo-Åsmund Lund
Journal:  J Appl Clin Med Phys       Date:  2016-11-24       Impact factor: 2.102

3.  Monitoring deep inspiration breath hold for left-sided localized breast cancer radiotherapy with an in-house developed laser distance meter system.

Authors:  Christer A Jensen; Tatiana Abramova; Jomar Frengen; Jo-Åsmund Lund
Journal:  J Appl Clin Med Phys       Date:  2017-07-29       Impact factor: 2.102

4.  Setup errors in radiation therapy for thoracic tumor patients of different body mass index.

Authors:  Jin Zhao; Mingyun Zhang; Fushan Zhai; Haiyan Wang; Xingde Li
Journal:  J Appl Clin Med Phys       Date:  2018-03-01       Impact factor: 2.102

Review 5.  What is the impact of innovation on output in healthcare with a special focus on treatment innovations in radiotherapy? A literature review.

Authors:  Maria Jacobs; Liesbeth Boersma; Andre Dekker; Rachelle Swart; Philippe Lambin; Dirk de Ruysscher; Frank Verhaegen; Joost Stultiens; Bram Ramaekers; Frits van Merode
Journal:  Br J Radiol       Date:  2017-08-06       Impact factor: 3.039

6.  Mean heart dose variation over a course of breath-holding breast cancer radiotherapy.

Authors:  Nicolle Dunkerley; Frederick R Bartlett; Anna M Kirby; Philip M Evans; Ellen M Donovan
Journal:  Br J Radiol       Date:  2016-09-20       Impact factor: 3.039

7.  Translucent poly(vinyl alcohol) cryogel dosimeters for simultaneous dose buildup and monitoring during chest wall radiation therapy.

Authors:  Molham M Eyadeh; Mark A Weston; Janos Juhasz; Kevin R Diamond
Journal:  J Appl Clin Med Phys       Date:  2016-09-08       Impact factor: 2.102

8.  Design and Construction of A Laser-Based Respiratory Gating System For Implementation of Deep Inspiration Breathe Hold Technique in Radiotherapy Clinics.

Authors:  Mohammad Javad Keikhai Farzaneh; Shahrokh Nasseri; Mehdi Momennezhad; Roham Salek
Journal:  J Med Signals Sens       Date:  2018 Oct-Dec

9.  Evaluation of  interfraction setup variations for  postmastectomy radiation therapy using EPID-based in vivo dosimetry.

Authors:  Shengwei Kang; Jie Li; Jiabao Ma; Wei Zhang; Xiongfei Liao; Hou Qing; Tingqiang Tan; Xin Xin; Bin Tang; Angelo Piermattei; Lucia Clara Orlandini
Journal:  J Appl Clin Med Phys       Date:  2019-09-21       Impact factor: 2.102

10.  Voluntary breath-holding for breast cancer radiotherapy is consistent and stable.

Authors:  Ruth Colgan; Matthew James; Frederick R Bartlett; Anna M Kirby; Ellen M Donovan
Journal:  Br J Radiol       Date:  2015-08-13       Impact factor: 3.039

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.