X-ray area backlighter development at the National Ignition Facility (invited).

M A Barrios1, S P Regan2, K B Fournier1, R Epstein2, R Smith1, A Lazicki1, R Rygg1, D E Fratanduono1, J Eggert1, H-S Park1, C Huntington1, D K Bradley1, O L Landen1, G W Collins1.   

Abstract

1D spectral imaging was used to characterize the K-shell emission of Z ≈ 30-35 and Z ≈ 40-42 laser-irradiated foils at the National Ignition Facility. Foils were driven with up to 60 kJ of 3ω light, reaching laser irradiances on target between 0.5 and 20 × 10(15) W/cm(2). Laser-to-X-ray conversion efficiency (CE) into the Heα line (plus satellite emission) of 1.0%-1.5% and 0.15%-0.2% was measured for Z ≈ 30-32 and Z ≈ 40-42, respectively. Measured CE into Heα (plus satellite emission) of Br (Z = 35) compound foils (either KBr or RbBr) ranged between 0.16% and 0.29%. Measured spectra are compared with 1D non-local thermodynamic equilibrium atomic kinetic and radiation transport simulations, providing a fast and accurate predictive capability.

Entities:  

Year:  2014        PMID: 25430176     DOI: 10.1063/1.4891713

Source DB:  PubMed          Journal:  Rev Sci Instrum        ISSN: 0034-6748            Impact factor:   1.523


  1 in total

1.  Metastability of diamond ramp-compressed to 2 terapascals.

Authors:  A Lazicki; D McGonegle; J R Rygg; D G Braun; D C Swift; M G Gorman; R F Smith; P G Heighway; A Higginbotham; M J Suggit; D E Fratanduono; F Coppari; C E Wehrenberg; R G Kraus; D Erskine; J V Bernier; J M McNaney; R E Rudd; G W Collins; J H Eggert; J S Wark
Journal:  Nature       Date:  2021-01-27       Impact factor: 49.962