Literature DB >> 25426495

A dipole-assisted solid-phase extraction microchip combined with inductively coupled plasma-mass spectrometry for online determination of trace heavy metals in natural water.

Tsung-Ting Shih1, I-Hsiang Hsu, Shun-Niang Chen, Ping-Hung Chen, Ming-Jay Deng, Yu Chen, Yang-Wei Lin, Yuh-Chang Sun.   

Abstract

We employed a polymeric material, poly(methyl methacrylate) (PMMA), for fabricating a microdevice and then implanted the chlorine (Cl)-containing solid-phase extraction (SPE) functionality into the PMMA chip to develop an innovative on-chip dipole-assisted SPE technique. Instead of the ion-ion interactions utilized in on-chip SPE techniques, the dipole-ion interactions between the highly electronegative C-Cl moieties in the channel interior and the positively charged metal ions were employed to facilitate the on-chip SPE procedures. Furthermore, to avoid labor-intensive manual manipulation, a programmable valve manifold was designed as an interface combining the dipole-assisted SPE microchip and inductively coupled plasma-mass spectrometry (ICP-MS) to achieve the fully automated operation. Under the optimized operation conditions for the established system, the detection limits for each analyte ion were obtained based on three times the standard deviation of seven measurements of the blank eluent solution. The limits ranged from 3.48 to 20.68 ng L(-1), suggesting that this technique appears uniquely suited for determining the levels of heavy metal ions in natural water. Indeed, a series of validation procedures demonstrated that the developed method could be satisfactorily applied to the determination of trace heavy metals in natural water. Remarkably, the developed device was durable enough to be reused more than 160 times without any loss in its analytical performance. To the best of our knowledge, this is the first study reporting on the combination of a dipole-assisted SPE microchip and elemental analysis instrument for the online determination of trace heavy metal ions.

Entities:  

Mesh:

Substances:

Year:  2015        PMID: 25426495     DOI: 10.1039/c4an01421a

Source DB:  PubMed          Journal:  Analyst        ISSN: 0003-2654            Impact factor:   4.616


  1 in total

1.  Fabrication of a Dipole-assisted Solid Phase Extraction Microchip for Trace Metal Analysis in Water Samples.

Authors:  Tsung-Ting Shih; I-Hsiang Hsu; Ping-Hung Chen; Shun-Niang Chen; Sheng-Hao Tseng; Ming-Jay Deng; Yang-Wei Lin; Yuh-Chang Sun
Journal:  J Vis Exp       Date:  2016-08-07       Impact factor: 1.355

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.