Water can make the clearest ultrasonographic image during reduction of nasal fracture.

Yuka Shigemura1, Jun Akamatsu1, Naoya Sugita1, Takashi Nuri1, Koichi Ueda1.   

Abstract

Entities:  

Year:  2014        PMID: 25426386      PMCID: PMC4236364          DOI: 10.1097/GOX.0000000000000132

Source DB:  PubMed          Journal:  Plast Reconstr Surg Glob Open        ISSN: 2169-7574


× No keyword cloud information.

Sir:

Ultrasonography is now a very popular noninvasive imaging technique. It has been reported to be useful in the diagnosis and assessment of reduction in nasal bone fracture.[1-3] Ultrasonography can detect local and superficial fractures. However, it is difficult to see the whole nasal bone and the neighboring facial bones because the probe cannot be applied to such a complicated 3D structure.[4] Various media are used to solve the problem.[4] Ultrasound signals are attenuated by passing through the medium. The attenuation rate can be calculated by the following relationship: Attenuation volume (dB) = Attenuation index (dB/cm/MHz) × Depth (cm) × Frequency (MHz). The lager the attenuation index of the medium, the more signals are absorbed as they pass through the medium. The greater the depth of the medium, the more ultrasound is absorbed. The higher the frequency of the ultrasound, the greater is the absorption as it passes through the medium. The attenuation index of water is the lowest in the various media (Table 1). Therefore, a clear ultrasonographic image can be obtained if water can be utilized as the medium. We used saline as the coupling medium for ultrasonography in nasal bone fracture.
Table 1.

Attenuation Index of Various Media

Attenuation Index of Various Media To keep saline on the face, the outer frame of a snorkeling mask made of thermoplastic elastomer was used (Fig. 1). To prevent saline from entering the nasal cavity, we sealed the nostrils with medical tape. The ultrasound probe could be applied through the pool of saline without adding pressure to the nasal bone fracture site. The ethical committees of Chikamori Hospital and Osaka Medical College approved this method before it was performed.
Fig. 1.

Saline was used as coupling medium for ultrasonography. The outer frame of a snorkeling mask made of thermoplastic elastomer was used to keep saline on the face. To prevent saline from entering the nasal cavity, the nostrils were sealed with medical tape.

Saline was used as coupling medium for ultrasonography. The outer frame of a snorkeling mask made of thermoplastic elastomer was used to keep saline on the face. To prevent saline from entering the nasal cavity, the nostrils were sealed with medical tape. The ultrasonographic images in the 4 different directions (axis, sagittal, inclining views from the right and left side) were scanned routinely before and after reduction. The probe (Venue 40, GE healthcare; 12-MHz linear array) was used under general anesthesia. This method was applied in the treatment of a nasal bone fracture of a 16-year-old girl. In comparison with a preoperative computed tomography scan, we could obtain clearer ultrasonographic images and demonstrate successful reduction during operation (Fig. 2).
Fig. 2.

Case. A, A preoperative computed tomography scan image of a 16-year-old girl who had nasal bone fracture. B and C, Preoperative and postoperative ultrasound images with saline used as a coupling medium.

Case. A, A preoperative computed tomography scan image of a 16-year-old girl who had nasal bone fracture. B and C, Preoperative and postoperative ultrasound images with saline used as a coupling medium. For ultrasonography, a gel is most commonly used medium. However, with a gel it is often difficult to see the whole nose. A gel pad as a coupling medium has been reported (Sonagel).[4] It is useful, but there is a contact problem with the nose and attenuation during scanning because of heaviness, shape, size, and thickness. It is difficult to avoid pressure on the fracture site when applying the probe on the gel pad.[4] Water has a better attenuation index than a gel pad (Table 1) and does not add pressure on the fracture site during probe scanning; and the clearest image can be obtained. We believe our method is simple and very useful in evaluating reduction of nasal bone fractures. This method can be refined to provide a simpler procedure.

DISCLOSURE

The authors have no financial interest to declare in relation to the content of this article. The Article Processing Charge was paid for by the authors.
  3 in total

1.  High-resolution sonography for nasal fracture in children.

Authors:  Hyun Sook Hong; Jang Gyu Cha; Sang Hyun Paik; Seong Jin Park; Jai Soung Park; Dae Ho Kim; Hae Kyung Lee
Journal:  AJR Am J Roentgenol       Date:  2007-01       Impact factor: 3.959

2.  Usefulness of ultrasonography in the treatment of nasal bone fractures.

Authors:  Chan-Hum Park; Ho-Hoon Joung; Jun-Ho Lee; Seok Min Hong
Journal:  J Trauma       Date:  2009-12

3.  Comparison of high-resolution ultrasonography and computed tomography in the diagnosis of nasal fractures.

Authors:  Min Hee Lee; Jang Gyu Cha; Hyun Sook Hong; Jong Se Lee; Seong Jin Park; Sang Hyun Paik; Hae Kyung Lee
Journal:  J Ultrasound Med       Date:  2009-06       Impact factor: 2.153

  3 in total
  1 in total

1.  Ultrasonographic Images of Nasal Bone Fractures with Water Used as the Coupling Medium.

Authors:  Yuka Shigemura; Koichi Ueda; Jun Akamatsu; Naoya Sugita; Takashi Nuri; Yuki Otsuki
Journal:  Plast Reconstr Surg Glob Open       Date:  2017-05-30
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.