Literature DB >> 25426309

Effect of irradiation distance on image contrast in epi-optoacoustic imaging of human volunteers.

Gerrit Held1, Stefan Preisser1, H Günhan Akarçay1, Sara Peeters1, Martin Frenz1, Michael Jaeger1.   

Abstract

In combined clinical optoacoustic (OA) and ultrasound (US) imaging, epi-mode irradiation and detection integrated into one single probe offers flexible imaging of the human body. The imaging depth in epi-illumination is, however, strongly affected by clutter. As shown in previous phantom experiments, the location of irradiation plays an important role in clutter generation. We investigated the influence of the irradiation geometry on the local image contrast of clinical images, by varying the separation distance between the irradiated area and the acoustic imaging plane of a linear ultrasound transducer in an automated scanning setup. The results for different volunteers show that the image contrast can be enhanced on average by 25% and locally by more than a factor of two, when the irradiated area is slightly separated from the probe. Our findings have an important impact on the design of future optoacoustic probes for clinical application.

Entities:  

Keywords:  (170.3880) Medical and biological imaging; (170.5120) Photoacoustic imaging; (170.7170) Ultrasound

Year:  2014        PMID: 25426309      PMCID: PMC4242016          DOI: 10.1364/BOE.5.003765

Source DB:  PubMed          Journal:  Biomed Opt Express        ISSN: 2156-7085            Impact factor:   3.732


  24 in total

1.  Deformation-compensated averaging for clutter reduction in epiphotoacoustic imaging in vivo.

Authors:  Michael Jaeger; David Harris-Birtill; Andreas Gertsch; Elizabeth O'Flynn; Jeffrey Bamber
Journal:  J Biomed Opt       Date:  2012-06       Impact factor: 3.170

2.  Noninvasive imaging of hemoglobin concentration and oxygenation in the rat brain using high-resolution photoacoustic tomography.

Authors:  Xueding Wang; Xueyi Xie; Geng Ku; Lihong V Wang; George Stoica
Journal:  J Biomed Opt       Date:  2006 Mar-Apr       Impact factor: 3.170

3.  Quantitative spatially resolved measurement of tissue chromophore concentrations using photoacoustic spectroscopy: application to the measurement of blood oxygenation and haemoglobin concentration.

Authors:  Jan Laufer; Dave Delpy; Clare Elwell; Paul Beard
Journal:  Phys Med Biol       Date:  2006-12-14       Impact factor: 3.609

4.  Optoacoustic imaging of absorbing objects in a turbid medium: ultimate sensitivity and application to breast cancer diagnostics.

Authors:  Tatiana D Khokhlova; Ivan M Pelivanov; Victor V Kozhushko; Alexei N Zharinov; Vladimir S Solomatin; Alexander A Karabutov
Journal:  Appl Opt       Date:  2007-01-10       Impact factor: 1.980

5.  Real-time in vivo photoacoustic and ultrasound imaging.

Authors:  Roy G M Kolkman; Peter J Brands; Wiendelt Steenbergen; Ton G van Leeuwen
Journal:  J Biomed Opt       Date:  2008 Sep-Oct       Impact factor: 3.170

6.  Optical fluence distribution study in tissue in dark-field confocal photoacoustic microscopy using a modified Monte Carlo convolution method.

Authors:  Zhixing Xie; Lihong V Wang; Hao F Zhang
Journal:  Appl Opt       Date:  2009-06-10       Impact factor: 1.980

7.  Reduction of background in optoacoustic image sequences obtained under tissue deformation.

Authors:  Michael Jaeger; Lea Siegenthaler; Michael Kitz; Martin Frenz
Journal:  J Biomed Opt       Date:  2009 Sep-Oct       Impact factor: 3.170

Review 8.  Photoacoustic imaging and characterization of the microvasculature.

Authors:  Song Hu; Lihong V Wang
Journal:  J Biomed Opt       Date:  2010 Jan-Feb       Impact factor: 3.170

Review 9.  Optical properties of biological tissues: a review.

Authors:  Steven L Jacques
Journal:  Phys Med Biol       Date:  2013-05-10       Impact factor: 3.609

10.  Coregistered three-dimensional ultrasound and photoacoustic imaging system for ovarian tissue characterization.

Authors:  Andres Aguirre; Puyun Guo; John Gamelin; Shikui Yan; Mary M Sanders; Molly Brewer; Quing Zhu
Journal:  J Biomed Opt       Date:  2009 Sep-Oct       Impact factor: 3.170

View more
  13 in total

Review 1.  [Optoacoustic imaging].

Authors:  M Fournelle; S Tretbar
Journal:  Radiologe       Date:  2015-11       Impact factor: 0.635

2.  Photoacoustic reflection artifact reduction using photoacoustic-guided focused ultrasound: comparison between plane-wave and element-by-element synthetic backpropagation approach.

Authors:  Mithun Kuniyil Ajith Singh; Michael Jaeger; Martin Frenz; Wiendelt Steenbergen
Journal:  Biomed Opt Express       Date:  2017-03-20       Impact factor: 3.732

3.  Photoacoustic clutter reduction by inversion of a linear scatter model using plane wave ultrasound measurements.

Authors:  Hans-Martin Schwab; Martin F Beckmann; Georg Schmitz
Journal:  Biomed Opt Express       Date:  2016-03-24       Impact factor: 3.732

4.  In vivo demonstration of reflection artifact reduction in photoacoustic imaging using synthetic aperture photoacoustic-guided focused ultrasound (PAFUSion).

Authors:  Mithun Kuniyil Ajith Singh; Michael Jaeger; Martin Frenz; Wiendelt Steenbergen
Journal:  Biomed Opt Express       Date:  2016-07-11       Impact factor: 3.732

5.  In vivo dual-modality photoacoustic and optical coherence tomography imaging of human dermatological pathologies.

Authors:  Behrooz Zabihian; Jessika Weingast; Mengyang Liu; Edward Zhang; Paul Beard; Hubert Pehamberger; Wolfgang Drexler; Boris Hermann
Journal:  Biomed Opt Express       Date:  2015-07-31       Impact factor: 3.732

6.  Multiple irradiation sensing of the optical effective attenuation coefficient for spectral correction in handheld OA imaging.

Authors:  K Gerrit Held; Michael Jaeger; Jaro Rička; Martin Frenz; H Günhan Akarçay
Journal:  Photoacoustics       Date:  2016-06-04

7.  Feasibility of photoacoustic/ultrasound imaging of synovitis in finger joints using a point-of-care system.

Authors:  Pim J van den Berg; Khalid Daoudi; Hein J Bernelot Moens; Wiendelt Steenbergen
Journal:  Photoacoustics       Date:  2017-08-31

8.  Optimizing Irradiation Geometry in LED-Based Photoacoustic Imaging with 3D Printed Flexible and Modular Light Delivery System.

Authors:  Maju Kuriakose; Christopher D Nguyen; Mithun Kuniyil Ajith Singh; Srivalleesha Mallidi
Journal:  Sensors (Basel)       Date:  2020-07-06       Impact factor: 3.576

9.  Adjustable photoacoustic tomography probe improves light delivery and image quality.

Authors:  Gurneet S Sangha; Nicholas J Hale; Craig J Goergen
Journal:  Photoacoustics       Date:  2018-08-22

10.  Rapid scanning wide-field clutter elimination in epi-optoacoustic imaging using comb LOVIT.

Authors:  Tigran Petrosyan; Maria Theodorou; Jeff Bamber; Martin Frenz; Michael Jaeger
Journal:  Photoacoustics       Date:  2018-02-19
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.