Can we predict poor hemodynamic tolerance of intermittent hemodialysis with echocardiography in intensive care patients?

Loïc Chimot1, Arnaud Gacouin2, Nicolas Nardi2, Antoine Gros2, Sophie Mascle2, Sophie Marqué2, Christophe Camus2, Yves Le Tulzo2.   

Abstract

OBJECTIVES: Tolerance of intermittent hemodialysis is potentially poor for patients hospitalized in the intensive care unit, particularly those in shock. The aim of this study was to determine whether an evaluation of the hemodynamic state by echocardiography before an intermittent hemodialysis session could predict tolerance during the session.
METHODS: Before an intermittent hemodialysis session, transesophageal echocardiography was performed on sedated patients, and transthoracic echocardiography was performed on nonsedated patients. Poor tolerance during intermittent hemodialysis was defined by the following criteria: greater than 20% decrease in mean arterial pressure, need for fluid loading (≥500 mL), a 15% increase in catecholamine if the dose was stable before the session or doubling the speed of catecholamine infusion if necessary, arrhythmia, and the necessity to stop the session before its prescribed end.
RESULTS: A total of 54 patients were included: 20 (37%) were intubated under controlled mechanical ventilation (group 1) and underwent transesophageal echocardiography; 14 (26%) were intubated under pressure support ventilation (group 2) and underwent transthoracic echocardiography; and 20 (37%) had no ventilation support (group 3). Twenty-four patients (46%) had poor tolerance criteria. A comparison of groups showed no significant difference in tolerance. Similarly, there was no difference with and without ultrafiltration. Increased respiratory variation of the vena cava was not predictive of poor tolerance in groups 1 and 2. In group 3, there was greater variation in patients with poor tolerance. In patients receiving mechanical ventilation, greater respiratory variability of the maximum velocity measured in the pulmonary artery was predictive of poor tolerance.
CONCLUSIONS: The hemodynamic profile of patients receiving mechanical ventilation was unable to predict tolerance of an intermittent hemodialysis session. In patients without mechanical ventilation, hypovolemia before the session appeared to be predictive of poor tolerance.
© 2013 by the American Institute of Ultrasound in Medicine.

Entities:  

Keywords:  echocardiography; heart-lung interaction; hemodialysis; hemodynamic; intensive care sonography; mechanical ventilation

Mesh:

Year:  2014        PMID: 25425371     DOI: 10.7863/ultra.33.12.2145

Source DB:  PubMed          Journal:  J Ultrasound Med        ISSN: 0278-4297            Impact factor:   2.153


  3 in total

Review 1.  Body Fluids in End-Stage Renal Disease: Statics and Dynamics.

Authors:  Jeroen P Kooman; Frank M van der Sande
Journal:  Blood Purif       Date:  2018-12-05       Impact factor: 2.614

2.  Bedside prediction of intradialytic hemodynamic instability in critically ill patients: the SOCRATE study.

Authors:  Naïke Bigé; Jean-Rémi Lavillegrand; Julien Dang; Philippe Attias; Stéphanie Deryckere; Jérémie Joffre; Vincent Dubée; Gabriel Preda; Guillaume Dumas; Geoffroy Hariri; Claire Pichereau; Jean-Luc Baudel; Bertrand Guidet; Eric Maury; Pierre-Yves Boelle; Hafid Ait-Oufella
Journal:  Ann Intensive Care       Date:  2020-04-22       Impact factor: 6.925

3.  Preload dependence and hypotension: One of the causes and one of the consequences of poor tolerance of intermittent hemodialysis in the ICU?

Authors:  Jérôme Allyn; Laure Corradi; Nicolas Allou; Bernard Alex Gaüzère
Journal:  Crit Care       Date:  2016-06-10       Impact factor: 9.097