Literature DB >> 25421305

Dual mobility bearings withstand loading from steeper cup-inclinations without substantial wear.

LaQuawn Loving1, Lizeth Herrera, Samik Banerjee, Christopher Heffernan, Jim Nevelos, David C Markel, Michael A Mont.   

Abstract

Steep cup abduction angles with adverse joint loading may increase traditional polyethylene bearing wear in total hip arthroplasties. However, there have been few reports evaluating the effect of cup inclination on the wear of dual-mobility devices. In a hip joint simulation, we compared the short-term wear of two-sizes of modular highly cross-linked dual-mobility bearings (28 mm femoral head diameter/42 mm polyethylene insert outer diameter/54 mm acetabular shell diameter; 22.2 mm femoral head diameter/36 mm polyethylene insert outer diameter/48 mm acetabular shell diameter) at 50 and 65° of cup inclination with modular 28 mm femoral head on 54 mm cup diameter metal-on-highly cross-linked polyethylene bearings. Increasing inclination from 50-65° had no changes in volumetric wear of 28/42/54 mm (mean, 1.7 vs. 1.2 mm3 /million cycles, respectively; p = 0.50) and 22.2/36/48 mm (mean, 1.7 vs. 1.2 mm3/million cycles, respectively; p = 0.48) dual mobility bearings. At 65°, 22.2/36/48 mm dual-mobility bearings had lower volumetric loss (mean, 2.2 vs. 6.3 mm(3) ; p = 0.03) and wear rates (mean, 1.2 vs. 2.7 mm3/million cycles; p = 0.02) compared to metal-on-highly cross-linked polyethylene bearings. Modern-generation dual-mobility designs with highly cross-linked polyethylenes may potentially withstand edge-loading from steeper cup-inclinations without substantial decreases in wear.
© 2014 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

Entities:  

Keywords:  acetabular; arthroplasty; dual-mobility; inclination; wear

Mesh:

Substances:

Year:  2014        PMID: 25421305     DOI: 10.1002/jor.22774

Source DB:  PubMed          Journal:  J Orthop Res        ISSN: 0736-0266            Impact factor:   3.494


  13 in total

1.  Equivalent wear performance of dual mobility bearing compared with standard bearing in total hip arthroplasty: in vitro study.

Authors:  Gaël Gaudin; André Ferreira; Romain Gaillard; Jean Louis Prudhon; Jacques H Caton; Sébastien Lustig
Journal:  Int Orthop       Date:  2016-11-22       Impact factor: 3.075

2.  CORR Insights®: Spinal Fusion Is Associated With Changes in Acetabular Orientation and Reductions in Pelvic Mobility.

Authors:  Edward Ebramzadeh
Journal:  Clin Orthop Relat Res       Date:  2019-02       Impact factor: 4.176

Review 3.  Wear of dual-mobility cups: a review article.

Authors:  Anna Di Laura; Harry Hothi; Clement Battisti; Arianna Cerquiglini; Johann Henckel; John Skinner; Alister Hart
Journal:  Int Orthop       Date:  2016-12-09       Impact factor: 3.075

4.  Wear testing of a canine hip resurfacing implant that uses highly cross-linked polyethylene.

Authors:  Kevin J Warburton; John B Everingham; Jillian L Helms; Andrew J Kazanovicz; Katherine A Hollar; Jeff D Brourman; Steven M Fox; Trevor J Lujan
Journal:  J Orthop Res       Date:  2017-11-14       Impact factor: 3.494

5.  Highly crosslinked polyethylene: a safe alternative to conventional polyethylene for dual mobility cup mobile component. A biomechanical validation.

Authors:  Matthieu Malatray; Jean-Paul Roux; Stanislas Gunst; Vincent Pibarot; Julien Wegrzyn
Journal:  Int Orthop       Date:  2016-11-11       Impact factor: 3.075

6.  Dual mobility THR: Resolving instability and providing near normal range of movement.

Authors:  Sanjay Agarwala; Vivek Shetty; Shounak Taywade; Mayank Vijayvargiya; Mahmoud Bhingraj
Journal:  J Clin Orthop Trauma       Date:  2020-08-28

7.  Comparison of dual-mobility cup and unipolar cup for prevention of dislocation after revision total hip arthroplasty.

Authors:  Amanda Inez Gonzalez; Placido Bartolone; Anne Lubbeke; Elise Dupuis Lozeron; Robin Peter; Pierre Hoffmeyer; Panayiotis Christofilopoulos
Journal:  Acta Orthop       Date:  2016-11-14       Impact factor: 3.717

8.  Constrained liners, dual mobility or large diameter heads to avoid dislocation in THA.

Authors:  Olivier Guyen
Journal:  EFORT Open Rev       Date:  2017-03-13

9.  Risk factors and modes of failure in the modern dual mobility implant. A systematic review and meta-analysis.

Authors:  Fu-Yuan Pai; Hsuan-Hsiao Ma; Te-Feng Arthur Chou; Tsan-Wen Huang; Kuo-Chin Huang; Shang-Wen Tsai; Cheng-Fong Chen; Wei-Ming Chen
Journal:  BMC Musculoskelet Disord       Date:  2021-06-14       Impact factor: 2.362

10.  Catastrophic failure of a dual mobility bearing in a revision total hip arthroplasty.

Authors:  Brett G Brazier; Ethan R Wren; Michael J Blackmer; Dominic V Marino; Jason M Cochran
Journal:  Arthroplast Today       Date:  2018-04-22
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.