Literature DB >> 25420084

Cone-beam CT versus multi-slice CT systems for postoperative imaging of cochlear implantation--a phantom study on image quality and radiation exposure using human temporal bones.

Henricus J Theunisse1, Raoul M S Joemai, Thomas J J Maal, Jacob Geleijns, Emmanuel A M Mylanus, Berit M Verbist.   

Abstract

HYPOTHESIS: Image quality of low-dose multi-slice computed tomography (MSCT) after cochlear implantation is comparable to that of cone-beam computed tomography (CBCT).
BACKGROUND: CBCT has been described as a low-dose alternative with superior image quality to MSCT for postoperative cochlear implant (CI) imaging, but to our knowledge, no dose-matched comparisons of image quality have been published.
MATERIALS AND METHODS: Five human cochleae were implanted with CI electrodes and scanned on two CBCT and two MSCT systems. Four independent observers rated aspects of image quality on a five-point scale. CBCT scans were compared to clinical and dose-matched MSCT scans. Declining-dose MSCT protocols were compared to the clinical protocol. CT phantoms were used to determine effective dose and resolution for each acquisition protocol.
RESULTS: Effective dose of the CBCT protocols was 6 to 16% of the clinical MSCT dose. Visibility of cochlear inner and outer walls and overall image quality were positively correlated with radiation dose on MSCT and image quality was better with clinical MSCT than with CBCT protocols. In other comparisons, differences between systems were found, but a distinction between CBCT and MSCT could not be made.
CONCLUSION: CBCT and dose-matched MSCT are both suitable for postoperative CI imaging. Selecting a CT system and radiation dose depends on which cochlear structures need to be visualized.

Entities:  

Mesh:

Year:  2015        PMID: 25420084     DOI: 10.1097/MAO.0000000000000673

Source DB:  PubMed          Journal:  Otol Neurotol        ISSN: 1531-7129            Impact factor:   2.311


  7 in total

1.  Insertion characteristics and placement of the Mid-Scala electrode array in human temporal bones using detailed cone beam computed tomography.

Authors:  Aarno Dietz; Dzemal Gazibegovic; Jyrki Tervaniemi; Veli-Matti Vartiainen; Heikki Löppönen
Journal:  Eur Arch Otorhinolaryngol       Date:  2016-05-19       Impact factor: 2.503

2.  Dyna-CT of the temporal bone for case-specific three-dimensional rendering of the stapedial muscle for planning of electrically evoked stapedius reflex threshold determination during cochlear implantation directly from the stapedius muscle via a retrofacial approach: a pilot study.

Authors:  Gerd Fabian Volk; René Aschenbach; Maria Gadyuchko; Thomas Bitter; Sven Koscielny; Ulf Teichgräber; Orlando Guntinas-Lichius
Journal:  Eur Arch Otorhinolaryngol       Date:  2020-01-02       Impact factor: 2.503

3.  Cone-Beam CT Compared to Multi-Slice CT for the Diagnostic Analysis of Conductive Hearing Loss: A Feasibility Study.

Authors:  Pieter Kemp; Jiska Van Stralen; Pim De Graaf; Erwin Berkhout; Pepijn Van Horssen; Paul Merkus
Journal:  J Int Adv Otol       Date:  2020-08       Impact factor: 1.017

4.  Cone-beam CT versus Multidetector CT in Postoperative Cochlear Implant Imaging: Evaluation of Image Quality and Radiation Dose.

Authors:  R A Helal; R Jacob; M A Elshinnawy; A I Othman; I M Al-Dhamari; D W Paulus; T T Abdelaziz
Journal:  AJNR Am J Neuroradiol       Date:  2021-01-07       Impact factor: 3.825

5.  Computed Tomography Staging of Middle Ear Cholesteatoma.

Authors:  Ahmed Abdel Khalek Abdel Razek; Mohamed Rashad Ghonim; Bassem Ashraf
Journal:  Pol J Radiol       Date:  2015-06-25

6.  Possibility of differentiation of cochlear electrodes in radiological measurements of the intracochlear and chorda-facial angle position.

Authors:  I Diogo; U Walliczeck; J Taube; N Franke; A Teymoortash; J Werner; C Güldner
Journal:  Acta Otorhinolaryngol Ital       Date:  2016-08       Impact factor: 2.124

7.  A dose-neutral image quality comparison of different CBCT and CT systems using paranasal sinus imaging protocols and phantoms.

Authors:  Ari-Petteri Ronkainen; Ali Al-Gburi; Timo Liimatainen; Hanna Matikka
Journal:  Eur Arch Otorhinolaryngol       Date:  2022-01-27       Impact factor: 3.236

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.