Circuit oxygenator contributes to extracorporeal membrane oxygenation-induced hemolysis.

Duane C Williams1, Jennifer L Turi, Christoph P Hornik, Desiree K Bonadonna, Walter L Williford, Richard J Walczak, Kevin M Watt, Ira M Cheifetz.   

Abstract

Hemolysis can occur as a consequence of extracorporeal membrane oxygenation (ECMO) and is associated with increased mortality and morbidity. Shear stress generated by flow through the circuit and oxygenator is believed to cause ECMO-induced hemolysis. We hypothesize that either a smaller dimension oxygenator or an in-line hemofilter will increase ECMO-associated hemolysis. Circuits were configured with a Quadrox-D Adult oxygenator (surface area 1.8 m), Quadrox-iD Pediatric oxygenator (surface area 0.8 m), or Quadrox-D Adult oxygenator with an in-line hemofilter (N = 4) and ran for 6 hours. Samples were collected hourly from the ECMO circuit and a time-based hemolysis control. Plasma hemoglobin levels were assayed. Circuit-induced hemolysis at each time point was defined as the change in plasma hemoglobin standardized to the time-based hemolysis control. Plasma hemoglobin increased with the use of the smaller dimension pediatric oxygenator as compared with the adult oxygenator when controlling for ECMO run time (p = 0.02). Furthermore, there was a greater pressure gradient with the smaller dimension pediatric oxygenator (p < 0.05). Plasma hemoglobin did not change with the addition of the in-line hemofilter. The use of a smaller dimension pediatric oxygenator resulted in greater hemolysis and a higher pressure gradient. This may indicate that the increased shear forces augment ECMO-induced hemolysis.

Entities:  

Mesh:

Substances:

Year:  2015        PMID: 25419829      PMCID: PMC4537148          DOI: 10.1097/MAT.0000000000000173

Source DB:  PubMed          Journal:  ASAIO J        ISSN: 1058-2916            Impact factor:   2.872


  19 in total

Review 1.  The clinical sequelae of intravascular hemolysis and extracellular plasma hemoglobin: a novel mechanism of human disease.

Authors:  Russell P Rother; Leonard Bell; Peter Hillmen; Mark T Gladwin
Journal:  JAMA       Date:  2005-04-06       Impact factor: 56.272

2.  Shear-induced fragmentation of human erythrocytes.

Authors:  A R Williams
Journal:  Biorheology       Date:  1973-09       Impact factor: 1.875

3.  Hemolysis during cardiac extracorporeal membrane oxygenation: a case-control comparison of roller pumps and centrifugal pumps in a pediatric population.

Authors:  Jonathan Byrnes; Wes McKamie; Christopher Swearingen; Parthak Prodhan; Adnan Bhutta; Robert Jaquiss; Michiaki Imamura; Richard Fiser
Journal:  ASAIO J       Date:  2011 Sep-Oct       Impact factor: 2.872

4.  Hemolysis in stored red blood cell concentrates: modulation by haptoglobin or ulinastatin, a protease inhibitor.

Authors:  T Nishiyama; K Hanaoka
Journal:  Crit Care Med       Date:  2001-10       Impact factor: 7.598

5.  Extracorporeal membrane oxygenation in postcardiotomy patients: factors influencing outcome.

Authors:  T K Susheel Kumar; David Zurakowski; Heidi Dalton; Sachin Talwar; Ayana Allard-Picou; Lennart F Duebener; Pranava Sinha; Achintya Moulick
Journal:  J Thorac Cardiovasc Surg       Date:  2010-08       Impact factor: 5.209

6.  Induced cell trauma during in vitro perfusion: a comparison between two different perfusion systems.

Authors:  M Skogby; K Mellgren; K Adrian; L G Friberg; J Y Chevalier; G Mellgren
Journal:  Artif Organs       Date:  1998-12       Impact factor: 3.094

7.  Evaluation of oxygenators and centrifugal pumps for long-term pediatric extracorporeal membrane oxygenation.

Authors:  A P S Thiara; T N Hoel; F Kristiansen; H M Karlsen; A E Fiane; J L Svennevig
Journal:  Perfusion       Date:  2007-09       Impact factor: 1.972

8.  The need for standardizing the index of hemolysis.

Authors:  K Naito; K Mizuguchi; Y Nosé
Journal:  Artif Organs       Date:  1994-01       Impact factor: 3.094

9.  Significance of hemolysis on extracorporeal life support after cardiac surgery in children.

Authors:  Rasheed Gbadegesin; Shuang Zhao; John Charpie; Patrick D Brophy; William E Smoyer; Jen-Jar Lin
Journal:  Pediatr Nephrol       Date:  2008-11-12       Impact factor: 3.714

10.  Red cell hemolysis during processing and storage.

Authors:  R B Sawant; S K Jathar; S B Rajadhyaksha; P T Kadam
Journal:  Asian J Transfus Sci       Date:  2007-07
View more
  14 in total

1.  Impact of Hemolysis on Acute Kidney Injury and Mortality in Children Supported with Cardiac Extracorporeal Membrane Oxygenation.

Authors:  Santiago Borasino; Yuvraj Kalra; Ashley R Elam; Lawrence Carlisle O'Meara; Joseph G Timpa; Kellen G Goldberg; J Leslie Collins Gaddis; Jeffrey A Alten
Journal:  J Extra Corpor Technol       Date:  2018-12

2.  Plasma Free Hemoglobin Generation Using the EOS PMP Oxygenator and the CentriMag® Blood Pump.

Authors:  Ashley B Hodge; Matthew A Deitemyer; Victoria L Duffy; Dmitry Tumin; Dorothy A Garbin; Kathleen K Nicol; Don Hayes; Mary J Cismowski; Andrew R Yates
Journal:  J Extra Corpor Technol       Date:  2018-06

3.  Amiodarone Extraction by the Extracorporeal Membrane Oxygenation Circuit.

Authors:  C Griffin McDaniel; C Cole Honeycutt; Kevin M Watt
Journal:  J Extra Corpor Technol       Date:  2021-03

4.  Remdesivir and GS-441524 Extraction by Ex Vivo Extracorporeal Life Support Circuits.

Authors:  Carina E Imburgia; Joseph E Rower; Danielle J Green; Autumn M Mcknite; Walter E Kelley; Christopher A Reilly; Kevin M Watt
Journal:  ASAIO J       Date:  2021-11-17       Impact factor: 3.826

Review 5.  Anticoagulation in ECMO patients: an overview.

Authors:  Gaurav Kumar; Ashish Maskey
Journal:  Indian J Thorac Cardiovasc Surg       Date:  2021-03-23

6.  Extracorporeal Membrane Oxygenation-Induced Hemolysis: An In Vitro Study to Appraise Causative Factors.

Authors:  Chris Hoi Houng Chan; Katrina K Ki; Meili Zhang; Cooper Asnicar; Hwajin Cho; Carmen Ainola; Mahe Bouquet; Silver Heinsar; Jo Philipp Pauls; Gianluigi Li Bassi; Jacky Suen; John F Fraser
Journal:  Membranes (Basel)       Date:  2021-04-25

7.  Parallel veno-venous and veno-arterial extracorporeal membrane circuits for coexisting refractory hypoxemia and cardiovascular failure: a case report.

Authors:  Jose R Navas-Blanco; Sofia A Lifgren; Roman Dudaryk; Jeffrey Scott; Matthias Loebe; Ali Ghodsizad
Journal:  BMC Anesthesiol       Date:  2021-03-12       Impact factor: 2.217

Review 8.  Overview of Veno-Arterial Extracorporeal Membrane Oxygenation (VA-ECMO) Support for the Management of Cardiogenic Shock.

Authors:  Adamantios Tsangaris; Tamas Alexy; Rajat Kalra; Marinos Kosmopoulos; Andrea Elliott; Jason A Bartos; Demetris Yannopoulos
Journal:  Front Cardiovasc Med       Date:  2021-07-07

9.  Technical-Induced Hemolysis in Patients with Respiratory Failure Supported with Veno-Venous ECMO - Prevalence and Risk Factors.

Authors:  Karla Lehle; Alois Philipp; Florian Zeman; Dirk Lunz; Matthias Lubnow; Hans-Peter Wendel; Laszlo Göbölös; Christof Schmid; Thomas Müller
Journal:  PLoS One       Date:  2015-11-25       Impact factor: 3.240

Review 10.  The Complex Relationship of Extracorporeal Membrane Oxygenation and Acute Kidney Injury: Causation or Association?

Authors:  Daniel J Kilburn; Kiran Shekar; John F Fraser
Journal:  Biomed Res Int       Date:  2016-02-24       Impact factor: 3.411

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.