Literature DB >> 25419648

Humidity affects relative ion abundance in direct analysis in real time mass spectrometry of hexamethylene triperoxide diamine.

G Asher Newsome1, Luke K Ackerman, Kevin J Johnson.   

Abstract

Unstable explosive hexamethylene triperoxide diamine (HMTD) is dangerous in quantity and benefits from the minimal sampling handling associated with atmospheric pressure chemical ionization for mass spectral analysis. Seasonal variation observed in HMTD mass spectra suggested a humidity dependence. Therefore, direct analysis in real time (DART) ionization mass spectra were acquired at a range of humidity values. An enclosure was designed to fit around the ion source and mass spectrometer inlet at atmospheric pressure. The enclosure was supplied with controlled amounts of humidified air from a test atmosphere generator to create programmable conditions for ambient analysis. The relative abundance and fragmentation of analyte ions were observed to change reliably with changing humidity values and, to a lesser degree, temperature. Humidity at such plasma-based ion sources should be regulated to avoid ∼90% shifts in relative ion abundance and provide stability and reproducibility of HMTD analysis.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 25419648     DOI: 10.1021/ac503652x

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  7 in total

Review 1.  Recent advances in ambient mass spectrometry of trace explosives.

Authors:  Thomas P Forbes; Edward Sisco
Journal:  Analyst       Date:  2018-04-30       Impact factor: 4.616

2.  Humidity Effects on Fragmentation in Plasma-Based Ambient Ionization Sources.

Authors:  G Asher Newsome; Luke K Ackerman; Kevin J Johnson
Journal:  J Am Soc Mass Spectrom       Date:  2015-09-18       Impact factor: 3.109

3.  Reactions of Organic Peroxides with Alcohols in Atmospheric Pressure Chemical Ionization-the Pitfalls of Quantifying Triacetone Triperoxide (TATP).

Authors:  Kevin Colizza; Alexander Yevdokimov; Lindsay McLennan; James L Smith; Jimmie C Oxley
Journal:  J Am Soc Mass Spectrom       Date:  2017-11-07       Impact factor: 3.109

4.  In-Line Reactions and Ionizations of Vaporized Diphenylchloroarsine and Diphenylcyanoarsine in Atmospheric Pressure Chemical Ionization Mass Spectrometry.

Authors:  Akihiko Okumura; Yasuaki Takada; Susumu Watanabe; Hiroaki Hashimoto; Naoya Ezawa; Yasuo Seto; Yasuo Takayama; Ryoji Sekioka; Shintaro Yamaguchi; Shintaro Kishi; Takafumi Satoh; Tomohide Kondo; Hisayuki Nagashima; Tomoki Nagoya
Journal:  J Am Soc Mass Spectrom       Date:  2016-04-20       Impact factor: 3.109

5.  Simplified screening approach of anabolic steroid esters using a compact atmospheric solid analysis probe mass spectrometric system.

Authors:  Ane Arrizabalaga-Larrañaga; Paul W Zoontjes; Johan J P Lasaroms; Michel W F Nielen; Marco H Blokland
Journal:  Anal Bioanal Chem       Date:  2022-02-27       Impact factor: 4.478

6.  Sorbent Film-Coated Passive Samplers for Explosives Vapour Detection Part A: Materials Optimisation and Integration with Analytical Technologies.

Authors:  Gillian L McEneff; Bronagh Murphy; Tony Webb; Dan Wood; Rachel Irlam; Jim Mills; David Green; Leon P Barron
Journal:  Sci Rep       Date:  2018-04-11       Impact factor: 4.379

7.  Utilizing Surface Acoustic Wave Nebulization (SAWN) for the Rapid and Sensitive Ambient Ionization Mass Spectrometric Analysis of Organic Explosives.

Authors:  Lauren Pintabona; Alina Astefanei; Garry L Corthals; Arian C van Asten
Journal:  J Am Soc Mass Spectrom       Date:  2019-10-28       Impact factor: 3.109

  7 in total