Literature DB >> 25417912

EDTA assisted highly selective detection of As(3+) on Au nanoparticle modified glassy carbon electrodes: facile in situ electrochemical characterization of Au nanoparticles.

Hsiao-Hua Chen1, Jing-Fang Huang.   

Abstract

A facile electrochemical characterization technique of Au nanoparticles (AuNPs) developed by Wang et al. ( Wang, Y.; Laborda, E.; Salter, C.; Crossley, A.; Compton, R. G. Analyst 2012 , 137 , 4693 - 4697 ) was used to track the variation in the particle size and density of AuNPs in situ and to assist in optimizing the conditions of analysis and catalysis. In this method, the combination of total surface area determined by Pb underpotential deposition (UPD) and the amount of Au obtained by anodic stripping of Au in HCl solution was used to evaluate the average diameter of AuNPs and the number of particles on the electrode. The detection of As(3+) in aqueous solution by a AuNP modified glassy carbon electrode (Aunano@GCE) using the electrochemical characterization technique was examined. The AuNPs with a uniform shape and size, deposited onto the GCEs using multiple-scan cyclic voltammetry (MSCV), were suitable for the electrochemical evaluation. The calibration curve for the detection of As(3+) had a dynamic range of 0.1-15.0 μg L(-1) (from 1.30 to 200 nM, y = 0.21x (in μA L μg(-1)) + 0.01 (R(2) = 0.999)) and showed a sensitivity of 0.21 μA L μg(-1) (16.15 μA μM(-1)). A detection limit as low as 0.0025 μg L(-1) (32.5 pM) was achieved. The chelating agent ethylenediaminetetraacetate (EDTA) selectively chelated with the interfering metal ions and effectively inhibited the interfering ions from competing with the ion of interest (As(3+)), in the preconcentration process. The presence of EDTA effectively eliminated interference from several metal ions, especially Cu(2+) and Hg(2+). This method was validated by analyzing the As(3+) content in real water samples.

Entities:  

Year:  2014        PMID: 25417912     DOI: 10.1021/ac504044w

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  3 in total

Review 1.  Recent progress regarding electrochemical sensors for the detection of typical pollutants in water environments.

Authors:  Yao Liu; Qiang Xue; Chunwen Chang; Rong Wang; Zeyu Liu; Lin He
Journal:  Anal Sci       Date:  2022-02-28       Impact factor: 2.081

2.  Fabrication of Robust Hydrogen Evolution Reaction Electrocatalyst Using Ag2Se by Vacuum Evaporation.

Authors:  Sajjad Hussain; Jinwoong Chae; Kamran Akbar; Dhanasekaran Vikraman; Linh Truong; Bilal Abbas Naqvi; Yawar Abbas; Hyun-Seok Kim; Seung-Hyun Chun; Gunn Kim; Jongwan Jung
Journal:  Nanomaterials (Basel)       Date:  2019-10-15       Impact factor: 5.076

Review 3.  Recent Progress in Nanobiosensors for Precise Detection of Blood Glucose Level.

Authors:  Haniye Khosravi Ardakani; Mitra Gerami; Mostafa Chashmpoosh; Navid Omidifar; Ahmad Gholami
Journal:  Biochem Res Int       Date:  2022-01-17
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.