Literature DB >> 25415713

Effective doses in children: association with common complex imaging techniques used during interventional radiology procedures.

Priscilla Lai1, Sarah M McNeil, Christopher L Gordon, Bairbre L Connolly.   

Abstract

OBJECTIVE: The purpose of this study was to determine the range of effective doses associated with imaging techniques used during interventional radiology procedures on children.
MATERIALS AND METHODS: A pediatric phantom set (1, 5, and 10 years) coupled with high-sensitivity metal oxide semiconductor field effect transistor (MOSFET) dosimeters was used to calculate effective doses. Twenty MOSFETs were inserted into each phantom at radiosensitive organ locations. The phantoms were exposed to mock head, chest, and abdominal interventional radiology procedures performed with different geometries and magnifications. Fluoroscopy, digital subtraction angiography (DSA), and spin angiography were simulated on each phantom. Road mapping was conducted only on the 5-year-old phantom. International Commission on Radiological Protection publication 103 tissue weights were applied to the organ doses recorded with the MOSFETs to determine effective dose. For easy application to clinical cases, doses were normalized per minute of fluoroscopy and per 10 frames of DSA or spin angiography.
RESULTS: Effective doses from DSA, angiography, and fluoroscopy were higher for younger ages because of magnification use and were largest for abdominal procedures. DSA of the head, chest, and abdomen (normalized per 10 frames) imparted doses 2-3 times as high as corresponding doses per minute of fluoroscopy while all other factors remained unchanged (age, projection, collimation, magnification). Three to five frames of DSA imparted an effective dose equal to doses from 1 minute of fluoroscopy. Doses from spin angiography were almost one-half the doses received from an equivalent number of frames of DSA.
CONCLUSION: Patient effective doses during interventional procedures vary substantially depending on procedure type but tend to be higher because of magnification use in younger children and higher in the abdomen.

Entities:  

Keywords:  effective dose; interventional radiology

Mesh:

Year:  2014        PMID: 25415713     DOI: 10.2214/AJR.13.11445

Source DB:  PubMed          Journal:  AJR Am J Roentgenol        ISSN: 0361-803X            Impact factor:   3.959


  3 in total

1.  Fluoroless catheter ablation of various right and left sided supra-ventricular tachycardias in children and adolescents.

Authors:  Matevž Jan; David Žižek; Katja Rupar; Uroš Mazić; Dimitrij Kuhelj; Nikola Lakič; Borut Geršak
Journal:  Int J Cardiovasc Imaging       Date:  2016-08-04       Impact factor: 2.357

2.  A Randomized Trial of Ultrasound- versus. Fluoroscopy-Guided Subclavian Vein Catheterization in Children with Hematologic Disease.

Authors:  Huajin Pang; Yong Chen; Xuehan Liu; Xiaofeng He; Weizhen Wang; Zhi Liu
Journal:  Indian J Pediatr       Date:  2019-07-22       Impact factor: 1.967

3.  Fluoroscopy-guided subclavian vein catheterization in 203 children with hematologic disease.

Authors:  Huajin Pang; Yong Chen; Xiaofeng He; Qingle Zeng; Peng Ye
Journal:  Medicine (Baltimore)       Date:  2018-12       Impact factor: 1.817

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.