Literature DB >> 25415483

Management of C1-2 traumatic fractures using an intraoperative 3D imaging-based navigation system.

Francesco Costa1, Alessandro Ortolina, Luca Attuati, Andrea Cardia, Massimo Tomei, Marco Riva, Luca Balzarini, Maurizio Fornari.   

Abstract

OBJECT: Fractures of C-1 and C-2 are complex and surgical management may be difficult and challenging due to the anatomical relationship sbetween the vertebrae and neurovascular structures. The aim of this study was to evaluate the role, reliability, and accuracy of cervical fixation using the O-arm intraoperative 3D image-based navigation system.
METHODS: The authors evaluated patients who underwent a navigation system-based surgery for stabilization of a fracture of C-1 and/or C-2 from August 2011 to August 2013. All of the fixation screws were intraoperatively checked and their position was graded.
RESULTS: The patient population comprised 17 patients whose median age was 47.6 years. The surgical procedures were as follows: anterior dens screw fixation in 2 cases, transarticular fixation of C-1 and C-2 in 1 case, fixation using the Harms technique in 12 cases, and occipitocervical fixation in 2 cases. A total of 67 screws were placed. The control intraoperative CT scan revealed 62 screws (92.6%) correctly placed, 4 (5.9%) with a minor cortical violation (<2 mm), and only 1 screw (1.5%) that was judged to be incorrectly placed and that was immediately corrected. No vascular injury of the vertebral artery was observed either during exposition or during screw placement. No implant failure was observed.
CONCLUSIONS: The use of a navigation system based on an intraoperative CT allows a real-time visualization of the vertebrae, reducing the risks of screw misplacement and consequent complications.

Entities:  

Keywords:  IGS = image-guided system; O-arm; VA = vertebral artery; cervical fracture; radiation dose; screw misplacement; spinal navigation

Mesh:

Year:  2014        PMID: 25415483     DOI: 10.3171/2014.10.SPINE14122

Source DB:  PubMed          Journal:  J Neurosurg Spine        ISSN: 1547-5646


  12 in total

Review 1.  C1 fractures: a review of diagnoses, management options, and outcomes.

Authors:  Loren B Mead; Paul W Millhouse; Jonathan Krystal; Alexander R Vaccaro
Journal:  Curr Rev Musculoskelet Med       Date:  2016-09

Review 2.  [Spinal navigation for posterior cervical and cervicothoracic instrumentation].

Authors:  M Richter; D Ploux
Journal:  Oper Orthop Traumatol       Date:  2019-06-13       Impact factor: 1.154

Review 3.  [Intraoperative 3D imaging in spinal surgery].

Authors:  O Gonschorek; S Hauck; V Bühren
Journal:  Unfallchirurg       Date:  2016-10       Impact factor: 1.000

Review 4.  [Relevance of spinal navigation in reconstructive surgery of the cervical spine].

Authors:  R Kothe; M Richter
Journal:  Orthopade       Date:  2018-06       Impact factor: 1.087

Review 5.  Differences between Manufacturers of Computed Tomography-Based Computer-Assisted Surgery Systems Do Exist: A Systematic Literature Review.

Authors:  Anas Nooh; Joushua Lubov; Ahmed Aoude; Sultan Aldebeyan; Peter Jarzem; Jean Ouellet; Michael H Weber
Journal:  Global Spine J       Date:  2017-02-01

6.  Comparative Analysis of Surgical Outcomes of C1-2 Fusion Spine Surgery between Intraoperative Computed Tomography Image Based Navigation-Guided Operation and Fluoroscopy-Guided Operation.

Authors:  Jun Seok Lee; Dong Wuk Son; Su Hun Lee; Sung Soon Ki; Sang Weon Lee; Geun Sung Song
Journal:  J Korean Neurosurg Soc       Date:  2020-02-27

Review 7.  Intraoperative image guidance for cervical spine surgery.

Authors:  Sertac Kirnaz; Harry Gebhard; Taylor Wong; Raj Nangunoori; Franziska Anna Schmidt; Kosuke Sato; Roger Härtl
Journal:  Ann Transl Med       Date:  2021-01

8.  Intraoperative imaging and navigation for C1-C2 posterior fusion.

Authors:  Ran Harel; Maya Nulman; Nachshon Knoller
Journal:  Surg Neurol Int       Date:  2019-07-26

9.  3D imaging and stealth navigation instead of CT guidance for radiofrequency ablation of osteoid osteomas: a series of 52 patients.

Authors:  Ran Ankory; Assaf Kadar; Doron Netzer; Haggai Schermann; Yair Gortzak; Shlomo Dadia; Yehuda Kollander; Ortal Segal
Journal:  BMC Musculoskelet Disord       Date:  2019-12-01       Impact factor: 2.362

10.  Combined 3-dimensional printing model and 3-dimensional fluoroscopic navigation to assist C2 pedicle screw insertion: A case report.

Authors:  Hao-Tian Xu; Shuang Zheng; Rong-Peng Dong; Tong Yu; Jian-Wu Zhao
Journal:  Medicine (Baltimore)       Date:  2020-10-23       Impact factor: 1.817

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.