The influence of the size of the grid used for dose calculation on the accuracy of dose estimation.

A Niemierko1, M Goitein.   

Abstract

The standard presentation of a dose distribution as an isodose map is based on interpolation between dose values calculated on a matrix of equally spaced points. We explored the question of how the spacing of the grid used for the dose matrix affects the error due to interpolating the dose at any point. We defined two types of errors: the dose error, which is the difference between the interpolated and true dose at a given point; and the position error, which is the distance between the point of interest and the nearest point which has, in fact, the dose value estimated for the point of interest. We examine the problem using both an analytical beam profile (a Fermi function) and measured 60Co, x-ray and proton beam profiles. Our analysis showed that the interpolation errors are proportional to the curvature of the dose distribution and are relatively high in regions on either side of, but not including, the steepest part of the penumbra. Our results showed how big an interpolation error one should expect for a given size of the calculation grid. The specification of accuracy should be cast in the form of a pair of requirements, one for dose and the other for position. At a given point, only one of the two requirements needs to be satisfied. The position requirement is almost always the less demanding in clinical practice and permits the use of a larger grid spacing than if only a dose requirement is applied.(ABSTRACT TRUNCATED AT 250 WORDS)

Mesh:

Substances:

Year:  1989        PMID: 2541326     DOI: 10.1118/1.596419

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  6 in total

1.  Dose Super-Resolution in Prostate Volumetric Modulated Arc Therapy Using Cascaded Deep Learning Networks.

Authors:  Dong-Seok Shin; Kyeong-Hyeon Kim; Sang-Won Kang; Seong-Hee Kang; Jae-Sung Kim; Tae-Ho Kim; Dong-Su Kim; Woong Cho; Tae Suk Suh; Jin-Beom Chung
Journal:  Front Oncol       Date:  2020-11-16       Impact factor: 6.244

2.  Investigating the dosimetric effects of grid size on dose calculation accuracy using volumetric modulated arc therapy in spine stereotactic radiosurgery.

Authors:  Chin Snyder Karen; Manju Liu; Bo Zhao; Yimei Huang; Wen Ning; Indrin J Chetty; M Salim Siddiqui
Journal:  J Radiosurg SBRT       Date:  2017

3.  Optimal set of grid size and angular increment for practical dose calculation using the dynamic conformal arc technique: a systematic evaluation of the dosimetric effects in lung stereotactic body radiation therapy.

Authors:  Ji-Yeon Park; Siyong Kim; Hae-Jin Park; Jeong-Woo Lee; Yeon-Sil Kim; Tae-Suk Suh
Journal:  Radiat Oncol       Date:  2014-01-04       Impact factor: 3.481

4.  Impact of grid size on uniform scanning and IMPT plans in XiO treatment planning system for brain cancer.

Authors:  Suresh Rana; Yuanshui Zheng
Journal:  J Appl Clin Med Phys       Date:  2015-09-08       Impact factor: 2.102

5.  Comparison of User-Directed and Automatic Mapping of the Planned Isocenter to Treatment Space for Prostate IGRT.

Authors:  Zijie Xu; Ronald Chen; Andrew Wang; Andrea Kress; Mark Foskey; An Qin; Timothy Cullip; Gregg Tracton; Sha Chang; Joel Tepper; Di Yan; Edward Chaney
Journal:  Int J Biomed Imaging       Date:  2013-11-21

6.  The Impact of the Grid Size on TomoTherapy for Prostate Cancer.

Authors:  Motohiro Kawashima; Hidemasa Kawamura; Masahiro Onishi; Yosuke Takakusagi; Noriyuki Okonogi; Atsushi Okazaki; Tetsuo Sekihara; Yoshitaka Ando; Takashi Nakano
Journal:  J Med Phys       Date:  2017 Jul-Sep