| Literature DB >> 25408704 |
Maryam Niknejadi1, Farnaz Akhbari1, Fatemeh Niknejad1, Gholamreza Khalili2, Marzieh Shiva3.
Abstract
BACKGROUND: Traditionally, septate uterus was diagnosed with invasive method like hysterosalpingography and hysteroscopy. Nowadays transvaginal ultrasonography was reported to be a sensitive tool for detection of septate uterus too.Entities:
Keywords: Congenitalabnormalities; Ultrasonography; hysteroscopy
Year: 2014 PMID: 25408704 PMCID: PMC4233313
Source DB: PubMed Journal: Iran J Reprod Med ISSN: 1680-6433
Figure 1Uterus measuring: in coronal reformatted section, fundal depth is 6 mm and interosteal line is 38.7 mm
Cross tab between the result of 2-DUS and hysteroscopy (as a gold standard)
|
|
| |||
|---|---|---|---|---|
|
|
|
|
| |
| Normal | 11 | 4 | 12 | 2 |
| Arcuate | 5 | 8 | 8 | 1 |
| Subseptate | 1 | 3 | 18 | 6 |
| Septate | 0 | 0 | 3 | 6 |
| Total | 17 | 15 | 41 | 15 |
Data are presented as number.
Cross tab for the result of 3-DUS and hysteroscopy (as a gold standard)
|
|
| |||
|---|---|---|---|---|
|
|
|
|
| |
| Normal | 4 | 0 | 0 | 0 |
| Arcuate | 0 | 2 | 7 | 1 |
| Subseptate | 1 | 12 | 57 | 3 |
| Septate | 0 | 0 | 7 | 31 |
| Total | 6 | 14 | 71 | 35 |
Data are presented as number.
Interosteal line and fundal depth of 3DUS findings based on hysteroscopic classification
|
|
| |
|---|---|---|
| Arcuate | 33.21 ± 4.15 | 7.75 ± 1.65 |
| Subseptate | 32.84 ± 7.31 | 8.71 ± 2.48 |
| Septate | 34.58 ± 9.23 | 18.18 ± 10.89 |
Data are presented as mean±SD.
Figure 22D Sagittal and transverse views of the septate uterus
Figure 3Sagittal and coronal views of the various uterus normal (A), Arcuate (B), Subseptate (C, D), Septate (E).
Figure 4Real time 3D (4D) view of subseptate uterus.
Sensitivity, specificity, NPV and PPV of detecting CMA by 3DUS
|
|
|
|
|
|
|
|---|---|---|---|---|---|
| Wu et al ( 1997)(9) | 40 | 100 | 100 | 100 | 100 |
| Deutch et al (2008) (8) | 13 | 100 | 100 | 100 | 100 |
PPV: Positive predictive value NPV: Negative predictive value CMA: congenital mullerian anomaly
Data are presented as %.
Sensitivity, specificity, positive predictive value and negative predictive value in diagnosis of septate uterus by 3DUS
|
|
|
|
|
|
|
|
|---|---|---|---|---|---|---|
| Kupesic & Kurjak (1998) | Detection of a uterine septum | 86 | 98.38 | 100 | 100 | 96 |
| Kupesic et al (2002) | Detection of a uterine septum | 894 | 99.27 | 100 | 100 | 97.61 |
| Jurkovic et al (1998) | ||||||
| Detection of a normal uterus | 58 | 98 | 100 | 100 | 94 | |
| Detection of an arcuate uterus | 58 | 100 | 100 | 100 | 100 | |
| Detection of a major uterine anomaly | 58 | 100 | 100 | 100 | 100 | |
| Deutch et al (2008) | Detection of a septate uterus | 13 | 100 | 100 | 100 | 100 |
Data are presented as %.