Literature DB >> 2540862

Early detection of antibodies against rDNA-produced HIV proteins with a flow cytometric assay.

J J Scillian1, T M McHugh, M P Busch, M Tam, M J Fulwyler, D Y Chien, G N Vyas.   

Abstract

There is evidence that some human immunodeficiency virus (HIV)-infected individuals have prolonged periods of seronegativity. A flow cytometric immunoreactive bead (IRB) assay is described for quantitative, simultaneous, and early detection of antibodies to HIV. Polystyrene beads of four diameters, each size coated with a different HIV recombinant DNA-produced protein (p24, p31, gp41, or gp120), bound anti-HIV antibodies detected with fluorescent antiglobulin. The IRB assay was performed on a panel of blood donor samples, many giving consistently false-positive enzyme immunoassay (EIA) and indeterminant Western blot (WB) results. The IRB assay proved as sensitive and more specific than currently licensed EIA and WB tests. Results on serial samples from eight HIV-infected individuals indicated that quantitation of anti-p24 by IRB assay may be useful in monitoring disease progression. Sequential pre- and post-EIA seroconversion sera from 35 HIV-infected homosexual men were tested by the IRB assay using IgM- and IgG-specific fluorescent probes. All 35 cases were IRB assay positive for at least one rDNA-p either before (17 of 35, 49%) or at the time of EIA positivity. Eleven cases (31%) initially had only IgM anti-HIV, primarily to gp41 (17%). In two individuals, the IgM response was detected at least 18 months before EIA seroconversion. The IRB assay is a widely applicable analytic procedure, potentially useful in pretransfusion anti-HIV screening of blood.

Entities:  

Mesh:

Substances:

Year:  1989        PMID: 2540862

Source DB:  PubMed          Journal:  Blood        ISSN: 0006-4971            Impact factor:   22.113


  8 in total

Review 1.  Multiplexed and microparticle-based analyses: quantitative tools for the large-scale analysis of biological systems.

Authors:  John P Nolan; Francis Mandy
Journal:  Cytometry A       Date:  2006-05       Impact factor: 4.355

Review 2.  Multiplexed protein measurement: technologies and applications of protein and antibody arrays.

Authors:  Stephen F Kingsmore
Journal:  Nat Rev Drug Discov       Date:  2006-04       Impact factor: 84.694

Review 3.  Basic concepts of microarrays and potential applications in clinical microbiology.

Authors:  Melissa B Miller; Yi-Wei Tang
Journal:  Clin Microbiol Rev       Date:  2009-10       Impact factor: 26.132

Review 4.  Uses of flow cytometry in virology.

Authors:  J J McSharry
Journal:  Clin Microbiol Rev       Date:  1994-10       Impact factor: 26.132

Review 5.  Applications of flow cytometry to clinical microbiology.

Authors:  A Alvarez-Barrientos; J Arroyo; R Cantón; C Nombela; M Sánchez-Pérez
Journal:  Clin Microbiol Rev       Date:  2000-04       Impact factor: 26.132

6.  Simultaneous detection of multiplex-amplified human immunodeficiency virus type 1 RNA, hepatitis C virus RNA, and hepatitis B virus DNA using a flow cytometer microsphere-based hybridization assay.

Authors:  J P Defoort; M Martin; B Casano; S Prato; C Camilla; V Fert
Journal:  J Clin Microbiol       Date:  2000-03       Impact factor: 5.948

7.  Participating in the evolution of transfusion medicine from a dispensary into a discipline.

Authors:  Girish N Vyas
Journal:  Transfus Med Rev       Date:  2008-04

8.  Detection of respiratory syncytial virus infection in nasal aspirate samples by flow cytometry.

Authors:  S L Johnston; A Dalal; S Mason; J W Wilson; B S Robinson; S T Holgate
Journal:  Clin Diagn Virol       Date:  1994-08
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.