| Literature DB >> 25406910 |
Yanlong Tang1, Yue Zhou, Wei Du, Ning Liu, Chengzhi Zhang, Tianzhao Ouyang, Jinbo Hu.
Abstract
BACKGROUND: We sought to determine the comparative diagnostic performance of standard b-value (800-1000 s/mm2) versus low b-value (400-500 s/mm2) diffusion-weighted magnetic resonance imaging (DW-MRI) in the detection of renal cell carcinoma (RCC).Entities:
Mesh:
Year: 2014 PMID: 25406910 PMCID: PMC4289169 DOI: 10.1186/1471-2407-14-843
Source DB: PubMed Journal: BMC Cancer ISSN: 1471-2407 Impact factor: 4.430
Figure 1Flow diagram of study selection.
Characteristics of included studies
| Study | Design | Total number of patients | Total number of lesions imaged | Reference standard | Coil type | Field strength (T) | B-value (s/mm 2 ) |
|---|---|---|---|---|---|---|---|
| Wang 2010
[ | Retrospective | 83 | 85 | Histopathology | Surface phased-array coil | 3.0 | 500, 800 |
| Rosenkrantz 2010
[ | Retrospective | 57 | 57 | Histopathology | Torso phased-array coil | 1.5 | 400, 800 |
| Chandarana 2012
[ | Prospective | 26 | 26 | Histopathology | Torso phased-array coil | 1.5 | 1000 |
| Goyal 2013
[ | Retrospective | 100 | 80 | Histopathology | Phased-array body coil | 1.5 | 500 |
Methodological quality of included studies
| Item | Wang 2010
[ | Rosenkrantz 2010
[ | Chandarana 2012
[ | Goyal 2013
[ |
|---|---|---|---|---|
| Was the spectrum of patients clearly representative of the patients who will receive the test in practice? | Y | Y | Y | Y |
| Were selection criteria clearly described? | Y | Y | Y | Y |
| Is the reference standard likely to correctly classify the target condition? | Y | Y | Y | Y |
| Is the time period between reference standard and index test short enough to be reasonably sure that the target condition did not change between the two tests? | Y | Y | U | U |
| Did the whole sample or a random selection of the sample receive verification using a reference standard of diagnosis? | Y | Y | Y | N |
| Did patients receive the same reference standard regardless of the index test result? | Y | Y | Y | Y |
| Was the reference standard independent of the index test (i.e. the index test did not form part of the reference standard)? | Y | Y | Y | Y |
| Was the execution of the index test described in sufficient detail to permit replication of the test? | Y | Y | Y | Y |
| Was the execution of the reference standard described in sufficient detail to permit its replication? | Y | Y | Y | Y |
| Were the index test results interpreted without knowledge of the results of the reference standard? | Y | Y | Y | Y |
| Were the reference standard results interpreted without knowledge of the results of the index test? | Y | Y | U | U |
| Were the same clinical data available when test results were interpreted as would be available when the test is used in practice? | Y | Y | Y | Y |
| Were missing data on the index test handled correctly? | Y | Y | Y | Y |
| Were withdrawals from the study explained? | Y | Y | Y | Y |
Abbreviations: Y yes, N no, U unclear.
Figure 2Forest plots of sensitivity and specificity estimates for standard b-value DW-MRI in detecting renal cell carcinoma. Point estimates of (A) sensitivity and (B) specificity from each study are shown as solid red circles. The solid blue lines represent the 95% confidence intervals (CI). Circles are proportional to study size. The pooled estimates are denoted by the red diamonds at the bottom.
Figure 3Forest plots of sensitivity and specificity estimates for low b-value DW-MRI in detecting renal cell carcinoma. Point estimates of (A) sensitivity and (B) specificity from each study are shown as solid red circles. The solid blue lines represent the 95% confidence intervals (CI). Circles are proportional to study size. The pooled estimates are denoted by the red diamonds at the bottom.
Figure 4Summary receiving operating characteristic plot with best-fitting asymmetric curve for standard and low b-value DW-MRI in detecting renal cell carcinoma. Summary receiving operating characteristic (SROC) plot with best-fitting asymmetric curve for (A) standard and (B) low b-value DW-MRI. Each solid red circle represents each study in the meta-analysis. The blue curve is the regression line that summarizes the overall diagnostic accuracy. SROC = summary receiver operating characteristic; AUC = area under the curve; SE(AUC) = standard error of AUC; Q* = an index defined by the point on the SROC curve where the sensitivity and specificity are equal, which is the point closest to the top-left corner of the ROC space; SE(Q*) = standard error of Q* index.