INTRODUCTION: Due to lack of reliable imaging contrast from catheter radiofrequency ablation (RFA) lesions, the vast majority of current procedures rely on indirect indicators of ablation activity, resulting in a significant number of arrhythmia reoccurrences after RFA procedures and the need for repeat surgeries. The objective of this work is to develop an accurate method for on-the-fly assessment of the durability and size of lesions formed during RFA procedures. METHOD AND RESULTS: Radiofrequency catheter ablation on freshly excised porcine ventricular myocardial tissue was optoacoustically monitored by means of pulsed-laser illumination in the near-infrared spectrum. Lesion formation during ablation was captured at a rate of 10 Hz with a 256-detector optoacoustic imaging probe. Postablated samples were imaged using multispectral excitation in the wavelength range 740-860 nm to determine the lesion contrast spectrum. Tomographic reconstruction was performed to generate 3-dimensional images of the lesions, which were compared to photographs depicting the final ablated tissue samples. Video-rate 3-dimensional tomographic reconstructions depict formation of the lesion with high contrast and spatial resolution. The size and geometry of the lesion was shown to be in excellent agreement with the histological examinations. The wavelength dependence of the lesion contrast shows a contrast peak near 780 nm. CONCLUSION: Deep-tissue 3-dimensional monitoring of RFA lesion generation in real time was demonstrated for the first time in this work. The results suggest the potential of optoacoustic monitoring for providing critical feedback on lesion position and size during radiofrequency catheter ablation, improving safety and efficacy of these treatments.
INTRODUCTION: Due to lack of reliable imaging contrast from catheter radiofrequency ablation (RFA) lesions, the vast majority of current procedures rely on indirect indicators of ablation activity, resulting in a significant number of arrhythmia reoccurrences after RFA procedures and the need for repeat surgeries. The objective of this work is to develop an accurate method for on-the-fly assessment of the durability and size of lesions formed during RFA procedures. METHOD AND RESULTS: Radiofrequency catheter ablation on freshly excised porcine ventricular myocardial tissue was optoacoustically monitored by means of pulsed-laser illumination in the near-infrared spectrum. Lesion formation during ablation was captured at a rate of 10 Hz with a 256-detector optoacoustic imaging probe. Postablated samples were imaged using multispectral excitation in the wavelength range 740-860 nm to determine the lesion contrast spectrum. Tomographic reconstruction was performed to generate 3-dimensional images of the lesions, which were compared to photographs depicting the final ablated tissue samples. Video-rate 3-dimensional tomographic reconstructions depict formation of the lesion with high contrast and spatial resolution. The size and geometry of the lesion was shown to be in excellent agreement with the histological examinations. The wavelength dependence of the lesion contrast shows a contrast peak near 780 nm. CONCLUSION: Deep-tissue 3-dimensional monitoring of RFA lesion generation in real time was demonstrated for the first time in this work. The results suggest the potential of optoacoustic monitoring for providing critical feedback on lesion position and size during radiofrequency catheter ablation, improving safety and efficacy of these treatments.
Authors: Xiaowei Zhao; Xiaoyong Fu; Colin Blumenthal; Yves T Wang; Michael W Jenkins; Christopher Snyder; Mauricio Arruda; Andrew M Rollins Journal: Biomed Opt Express Date: 2018-11-20 Impact factor: 3.732
Authors: Sophinese Iskander-Rizk; Pieter Kruizinga; Antonius F W van der Steen; Gijs van Soest Journal: Biomed Opt Express Date: 2018-02-23 Impact factor: 3.732
Authors: Jaya Prakash; Mir Mehdi Seyedebrahimi; Ara Ghazaryan; Jaber Malekzadeh-Najafabadi; Vipul Gujrati; Vasilis Ntziachristos Journal: Proc Natl Acad Sci U S A Date: 2020-02-06 Impact factor: 11.205
Authors: Vincent Sayseng; Julien Grondin; Vasant A Salgaonkar; Christopher S Grubb; Maryam Basij; Mohammad Mehrmohammadi; Vivek Iyer; Daniel Wang; Hasan Garan; Elaine Y Wan; Elisa E Konofagou Journal: IEEE Trans Ultrason Ferroelectr Freq Control Date: 2020-04-15 Impact factor: 2.725
Authors: Ali Hariri; Jeanne Lemaster; Junxin Wang; AnanthaKrishnan S Jeevarathinam; Daniel L Chao; Jesse V Jokerst Journal: Photoacoustics Date: 2017-11-26
Authors: Malcolm C Finlay; Charles A Mosse; Richard J Colchester; Sacha Noimark; Edward Z Zhang; Sebastien Ourselin; Paul C Beard; Richard J Schilling; Ivan P Parkin; Ioannis Papakonstantinou; Adrien E Desjardins Journal: Light Sci Appl Date: 2017-12-01 Impact factor: 17.782