Literature DB >> 25398680

Dosimetric Comparison of Craniospinal Irradiation Using Different Tomotherapy Techniques.

X Zhang1, J Penagaricano2, E Y Han2, S Morrill2, M Hardee2, X Liang2, S K Gupta2, P M Corry2, V Ratanatharathom2.   

Abstract

The objective of this study is to compare the new and conventional tomotherapy treatment techniques and to evaluate dosimetric differences between them. A dosimetric analysis was performed by comparing planning target volume (PTV) median dose, 95% of PTV dose coverage, Paddick conformity index (CI), homogeneity index (HI), whole-body integral dose, and OAR median doses. The beam on time (BOT) and the effect of different jaw sizes and pitch values was studied. The study results indicated that the PTV dose coverage for all the techniques was comparable. Treatment plans using dynamic jaw reduced OAR doses to structures located at the treatment field edge compared to fixed jaw plans. The HT-3DCRT plans resulted in higher OAR doses to kidney, liver, and lung compared to the other techniques, and TD-IMRT provided the best dose sparing to liver compared to other techniques. Whole-body integral dose differences were found to be insignificant among the techniques. BOT was found to be higher for fixed jaw treatment plan compared to dynamic jaw plan and comparable between all treatment techniques with 5-cm dynamic jaw. In studying effect of jaw size, better OAR sparing and HI were found for 2.5-cm jaw but at the expense of doubling of BOT as compared to 5-cm jaw. There was no significant improvement found in OAR sparing when the pitch value was increased. Increasing the pitch from 0.2 to 0.43, the CI was improved, HI improved only for 5-cm jaw size, and BOT decreased to approximately half of its original time.
© The Author(s) 2014.

Entities:  

Keywords:  TomoDirect IMRT; dosimetry; dynamic jaw; helical tomotherapy 3DCRT; helical tomotherapy IMRT

Mesh:

Year:  2014        PMID: 25398680     DOI: 10.1177/1533034614556932

Source DB:  PubMed          Journal:  Technol Cancer Res Treat        ISSN: 1533-0338


  4 in total

1.  Helical tomotherapy to LINAC plan conversion utilizing RayStation Fallback planning.

Authors:  Xin Zhang; Jose Penagaricano; Ganesh Narayanasamy; Peter Corry; TianXiao Liu; Maraboyina Sanjay; Nava Paudel; Steven Morrill
Journal:  J Appl Clin Med Phys       Date:  2017-01       Impact factor: 2.102

2.  Craniospinal irradiation using helical tomotherapy for central nervous system tumors.

Authors:  Sanziana R I Schiopu; Gregor Habl; Matthias Häfner; Sonja Katayama; Klaus Herfarth; Juergen Debus; Florian Sterzing
Journal:  J Radiat Res       Date:  2017-03-01       Impact factor: 2.724

3.  Dose evaluation indices for total body irradiation using TomoDirect with different numbers of ports: A comparison with the TomoHelical method.

Authors:  Yuki Kasai; Yukihide Fukuyama; Hiromi Terashima; Katsumasa Nakamura; Tomonari Sasaki
Journal:  J Appl Clin Med Phys       Date:  2019-02-05       Impact factor: 2.102

4.  Toxicity Reduction after Craniospinal Irradiation via Helical Tomotherapy in Patients with Medulloblastoma: A Unicentric Retrospective Analysis.

Authors:  Anil Öztunali; Khaled Elsayad; Sergiu Scobioala; Mohammed Channaoui; Uwe Haverkamp; Oliver Grauer; Ronald Sträter; Angela Brentrup; Walter Stummer; Kornelius Kerl; Hans Theodor Eich
Journal:  Cancers (Basel)       Date:  2021-01-28       Impact factor: 6.639

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.