| Literature DB >> 25398134 |
Anna Duszyk1, Maria Bierzyńska2, Zofia Radzikowska1, Piotr Milanowski3, Rafał Kuś3, Piotr Suffczyński3, Magdalena Michalska3, Maciej Łabęcki3, Piotr Zwoliński4, Piotr Durka3.
Abstract
Efforts to construct an effective brain-computer interface (BCI) system based on Steady State Visual Evoked Potentials (SSVEP) commonly focus on sophisticated mathematical methods for data analysis. The role of different stimulus features in evoking strong SSVEP is less often considered and the knowledge on the optimal stimulus properties is still fragmentary. The goal of this study was to provide insight into the influence of stimulus characteristics on the magnitude of SSVEP response. Five stimuli parameters were tested: size, distance, colour, shape, and presence of a fixation point in the middle of each flickering field. The stimuli were presented on four squares on LCD screen, with each square highlighted by LEDs flickering with different frequencies. Brighter colours and larger dimensions of flickering fields resulted in a significantly stronger SSVEP response. The distance between stimulation fields and the presence or absence of the fixation point had no significant effect on the response. Contrary to a popular belief, these results suggest that absence of the fixation point does not reduce the magnitude of SSVEP response. However, some parameters of the stimuli such as colour and the size of the flickering field play an important role in evoking SSVEP response, which indicates that stimuli rendering is an important factor in building effective SSVEP based BCI systems.Entities:
Mesh:
Year: 2014 PMID: 25398134 PMCID: PMC4232393 DOI: 10.1371/journal.pone.0112099
Source DB: PubMed Journal: PLoS One ISSN: 1932-6203 Impact factor: 3.240
Figure 1Time course of the experimental paradigm.
Parameters of the stimulus used in Experiment I.
| Tested parameter | Dimension | Inter-stimulus distance | Fixation point | Stimulus colour | Shape |
| Size | ∼0.57°, ∼1.49°, ∼2.60°, ∼3.72° | ∼4.76°, ∼3.50°, ∼2.30°, ∼1.26° | yes | white | square |
| Inter-stimulus distance | ∼2.60° | 0° , ∼2.30°, ∼5.27° | yes | white | square |
| Colour | ∼2.60° | ∼2.30° | yes | white, red, green, yellow, blue | square |
| Absence of fixation point | ∼2.60° | ∼2.30° | no | white | square |
| Shape | ∼2.60° | ∼2.30° | yes | white | circle, square |
Parameters of the stimulus used in Experiment II.
| Tested parameter | Dimension | Inter-stimulus distance | Fixation point | Stimulus colour | Shape |
| Size | ∼2.60°, ∼3.72° | ∼2.30°, ∼1.26° | yes | white | circle |
| Colour | ∼2.60° | ∼2.30° | yes | white, red, yellow | circle |
| Absence of fixation point | ∼2.60° | ∼2.30° | no | white | circle |
Figure 2Relative power increase for SSVEP response to different colours of stimuli.
Mean computed for all the subjects. Error bars indicate standard error of the mean (SEM). Horizontal lines above the bars indicate statistically significant differences on the level of p<0.001 (***), p<0.01 (**), and p<0.05 (*).
The results of post-hoc Wilcoxon signed-rank for comparison of SSVEP magnitude pairs evoked by different coloured stimuli in experiment I.
| yellow | blue | red | green | white | |
| yellow | - | χ2(1) = 19,24; p<0,001 | in. | in. | in. |
| blue | χ2(1) = 19,24; p<0,001 | - | χ2(1) = 11,88; p<0,01 | χ2(1) = 13,36; p<0,01 | χ2(1) = 19,25; p<0,001 |
| red | in. | χ2(1) = 11,88; p<0,01 | - | in. | in. |
| green | in. | χ2(1) = 13,36; p<0,01 | in. | - | in. |
| white | in. | χ2(1) = 19,25; p<0,001 | in. | in. | - |
Figure 3SSVEP responses to stimuli of different colours; organization of the plot as in .
Figure 4SSVEP responses to stimuli of different sizes; organization of the plot as in .
The results of post-hoc Wilcoxon signed-rank for comparison of SSVEP magnitude evoked by different sized stimuli in experiment II.
| ∼0.57° | ∼1.49° | ∼2.60°4 | ∼3.72° | |
| ∼0.57° | - | χ2(1) = 18,34; p<0,001 | χ2(1) = 26,19; p<0,001 in. | in. χ2(1) = 26,19; p<0,001; |
| ∼1.49° | χ2(1) = 18,34; p<0,001 | - | in. | χ2(1) = 8,55; p<0,05 |
| ∼2.60° | χ2(1) = 26,19; p<0,001 in. | in. | - | in. |
| ∼3.72° | χ2(1) = 26,19; p<0,001; in. | χ2(1) = 8,55; p<0,05 | in. | - |
Figure 5SSVEP responses to stimuli of different sizes; organization of the plot as in .
Figure 6SSVEP responses to stimuli with and without fixation point; organization of the plot as in .
Figure 7SSVEP responses to stimuli with and without fixation point; organization of the plot as in .
Figure 8SSVEP responses to circle and square stimuli; organization of the plot as in .
Figure 9SSVEP responses to circle and square stimuli; organization of the plot as in .