Literature DB >> 25391191

An unusual cause of progressive cyanosis post Fontan operation: congenital extra-hepatic porto-systemic shunt.

Thanarat Layangool, Vichao Kojaranjit, Worakan Promphan, Tawatchai Kirawittaya, Chaisit Sangtawesin, Pimpak Prachasilchai.   

Abstract

OBJECTIVE: To report an unusual case of progressive cyanosis post Fontan operation due to porto-systemic venous shunt and the result of its treatment. MATERIAL AND
METHOD: A patient with diagnosis of progressive cyanosis post Fontan operation from porto-systemic venous shunt at QSNICH
RESULTS: This is a case of twelve years old girl, who had diagnosis of situs solitus, levocardia, atrio-ventricular concordant, ventriculo-arterial concordant, hypoplastic right ventricle with large ventricular septal defect. She had pulmonary artery banding at 4 months of age followed by a non-fenestrated extra-cardiac conduit Fontan performed at 7 years and 7 months of age. During the first year of post operation, her systemic oxygen saturation (SpO2) was 93-94% after which it decreased to 87%, 84%, 75% at 1.5, 2.5 and 3 years after surgery, respectively. Clinically she also had progressive dyspnea on exertion. Diffuse pulmonary arterio-venous malformation was demonstrated by contrast echocardiogram during cardiac catheterization. Cardiac magnetic resonance angiography showed abnormal extra-hepatic portal vein to inferior vena cava shunt. After balloon test occlusion in the cath lab, which showed no change in the portal venous pressure, complete occlusion of this porto-systemic venous shunt was performed by using Amplatzer Vascular Plug II. Her systemic oxygen saturation increased to 83% with functional class I at one-year post occlusion.
CONCLUSION: The present report an unusual case of progressive cyanosis post Fontan operation due to pulmonary arteriovenous malformation, which was secondary to congenital extra-hepatic porto-systemic shunt. The venous blood from the intestinal and splenic veins was partially bypassing the liver into inferior vena cava. The patient's clinical condition and SpO2 improved after transcatheter occlusion of the shunt with the device.

Entities:  

Mesh:

Year:  2014        PMID: 25391191

Source DB:  PubMed          Journal:  J Med Assoc Thai        ISSN: 0125-2208


  1 in total

1.  Portosystemic shunt with hyperammonemia and high cardiac output as a complication after Fontan surgery.

Authors:  Kiyotaka Takefuta; Hideaki Senzaki; Atsuya Shimabukuro; Masahiro Nishibata; Seiichi Sato; Mami Nakayashiro
Journal:  J Cardiol Cases       Date:  2020-11-07
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.