The laboratory performance of the enFLOW(®) , buddy lite(™) and ThermoSens(®) fluid warmers.

H J Kim1, S M Yoo, J S Jung, S H Lee, K Sun, H S Son.   

Abstract

We measured heating of isotonic saline by three fluid warmers in six experiments: saline at 5 °C or 20 °C delivered at 30, 50 or 100 ml.min(-1) . At the three flow rates, the enFLOW(®) , buddy lite(™) and ThermoSens(®) systems heated 5 °C saline to mean (SD) temperatures of: 41.1 (0.5) °C, 37.7 (0.6) °C and 39.1 (0.6) °C; to 40.3 (0.8) °C, 33.9 (1.6) °C and 39.3 (0.7) °C; and to 37.1 (0.8) °C, 24.0 (1.3) °C and 37.6 (1.0) °C, respectively, p < 0.0001 for each experiment. The mean (SD) times taken to heat 5 °C saline were: 16.6 (1.7) s, 258.4 (58.9) s and 134.2 (79.6) s; 16.9 (1.8) s, 256.2 (62.2) s and 182.5 (74.5) s; and 21.5 (1.5) s, 275.9 (49.3) s and 313.5 (18.0) s, respectively, p < 0.0003 for each experiment. The results for saline at 20 °C were similar. The enFLOW system heated saline above 36 °C faster than the ThermoSens system, whereas the buddy lite often failed to achieve 36 °C.
© 2014 The Association of Anaesthetists of Great Britain and Ireland.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 25388624     DOI: 10.1111/anae.12906

Source DB:  PubMed          Journal:  Anaesthesia        ISSN: 0003-2409            Impact factor:   6.955


  4 in total

1.  Experimental comparison of performances of Mega Acer Kit, Ranger and ThermoSens according to flow rates and distances.

Authors:  Hong Ju Seo; Sang Hun Kim; Tae Hun An; Dong Joon Kim
Journal:  J Clin Monit Comput       Date:  2017-02-07       Impact factor: 2.502

2.  Mega Acer Kit® is more effective for warming the intravenous fluid than Ranger™ and ThermoSens® at 440 ml/h of infusion rate: an experimental performance study.

Authors:  Dong Joon Kim; Sang Hun Kim; Keum Young So; Tae Hun An
Journal:  Korean J Anesthesiol       Date:  2017-06-14

3.  Comparison of the performance of battery-operated fluid warmers.

Authors:  Amit Lehavi; Avraham Yitzhak; Refael Jarassy; Rami Heizler; Yeshayahu Shai Katz; Aeyal Raz
Journal:  Emerg Med J       Date:  2018-06-07       Impact factor: 2.740

4.  Impact of parylene coating on heating performance of intravenous fluid warmer: a bench study.

Authors:  Danielle K Bayoro; Herman Groepenhoff; Daniel Hoolihan; Edward A Rose; Michael J Pedro; Andreas D Waldmann
Journal:  BMC Anesthesiol       Date:  2022-02-10       Impact factor: 2.217

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.