Evaluation of a novel nicotine inhaler device: part 1--arterial and venous pharmacokinetics.

Chris Moyses1, Alex Hearn2, Andrew Redfern3.   

Abstract

INTRODUCTION: In the United Kingdom, licensed nicotine-containing products can be recommended to reduce the harm associated with smoking. Many smokers find currently available nicotine replacement products unsatisfactory. The arterial and venous pharmacokinetics (PK) of nicotine delivered via a novel inhaler device were determined.
METHODS: Results are reported for Parts A (N = 18) and C (N = 18) of a 4-part (A-D) Phase I study. Participants (18-55 years, ≥ 10 cigarettes/day, smoking within 1 hr of waking, expired carbon monoxide >10 ppm on screening) orally inhaled 2 single doses of nicotine (2 of 3 dose levels [0.22, 0.45, and 0.67 mg]) (Part A) and repeated hourly doses of 0.67 mg nicotine for 12 hr (Part C), via the novel device. Arterial and venous PK and tolerability were assessed.
RESULTS: In Part A, mean arterial plasma nicotine concentrations at 2 min after the start of inhalation were 1.10, 2.06, and 2.59 ng/mL for the 0.22, 0.45, and 0.67 mg doses, respectively. Mean maximum arterial plasma nicotine concentrations (C(max)) were 2.11, 3.73, and 4.38 ng/mL and mean times to C(max) were 10.2, 7.3, and 6.5 min after the start of inhalation for the 0.22, 0.45, and 0.67 mg doses, respectively. In Part C, the mean pre- and postdose venous plasma nicotine concentration increased steadily and fluctuated in the range 8-10 mg/mL after 9 hr. The novel device was well tolerated; most adverse events were mild.
CONCLUSION: The novel inhaler device delivers nicotine rapidly into the systemic circulation and offers a viable alternative to cigarettes for those finding it difficult to quit the behavioral and sensorial aspects of smoking.
© The Author 2014. Published by Oxford University Press on behalf of the Society for Research on Nicotine and Tobacco.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 25385878      PMCID: PMC4282122          DOI: 10.1093/ntr/ntu228

Source DB:  PubMed          Journal:  Nicotine Tob Res        ISSN: 1462-2203            Impact factor:   4.244


Introduction

Tobacco smoking is the leading cause of premature mortality worldwide and is responsible for almost one in five adult deaths over 35 years of age in England alone.[1,2] Until recently, measures to reduce the morbidity and mortality caused by smoking in the United Kingdom have focused on preventing the uptake of smoking and helping smokers to quit.[3] Although smoking cessation services have had an increasing impact in helping smokers wanting to stop,[4] the prevalence of smoking in England remains at around 20%.[1] Experience of the use of nicotine replacement therapy (NRT) products for smoking cessation has indicated that their effectiveness may be modest; the proportion of smokers who successfully quit for 52 weeks without any behavioral support using NRT products in primary and secondary care is estimated at just 7%–10%.[5] Existing NRT does not deliver nicotine in the same way as smoking and, moreover, the pharmacokinetic profile of the nicotine delivered may vary according to the NRT product used. Smoking leads to a rapid absorption of nicotine from the large surface area of the lungs and consequently to a sharp increase in arterial plasma nicotine levels.[6] Comparison of a cigarette to various NRT delivery systems indicates that peak venous nicotine concentrations are reached more rapidly with a cigarette or nasal spray than with an inhaler.[7] Research suggests that currently available NRT formulations may also fail to help many smokers quit because they also do not replace the unique sensory cues or rituals associated with smoking.[8,9] A recognition that these approaches are ineffective for many smokers has triggered a major change in tobacco control policy to embrace the implementation of a harm reduction approach to smoking.[10] The use of a tobacco harm reduction approach to smoking may include the use of licensed nicotine-containing products on a temporary or long-term basis.[10,11] The need for more effective and appealing products to provide satisfactory alternatives to smoking[8,12] has led to the development of a new nicotine inhaler device. The inhaler enables the user to obtain nicotine in a similar way to using a cigarette and to replicate many aspects of their smoking-related behavior. By relieving or preventing nicotine cravings or withdrawal symptoms associated with stopping smoking, the recently licensed inhaler device could be used to cut down or stop smoking as part of a tobacco harm reduction approach.[10] The novel nicotine inhaler contains no tobacco and, unlike electronic cigarettes, contains no battery or heating element to vaporize the nicotine, thus avoiding the associated production of other potentially toxic compounds[13] and also removing a potential source of variability in device performance.[14-18] We performed a four-part study to evaluate nicotine delivery from this novel nicotine inhaler device. The two parts reported here aimed to determine the pharmacokinetics (PK) and tolerability of orally inhaled nicotine via the novel inhaler device. The results of the remaining two study parts, which compared the novel nicotine inhaler with the Nicorette® Inhalator (10mg), are presented elsewhere.[19]

Methods

Study Design

This Phase I study comprised four parts: A, B, C, and D.

Part A:

A randomized, single-blind, multidose level study to determine the tolerability and arterial PK of orally inhaled nicotine via the novel nicotine inhaler device at three nicotine dose levels: 0.22, 0.45, and 0.67mg.

Part B:

A randomized, open-label, single-blind, three-way crossover study to determine the venous PK of orally inhaled nicotine at two dose levels (0.45 and 0.67mg) delivered via the novel nicotine inhaler device compared with the Nicorette® Inhalator (10mg).

Part C:

An open-label study to determine the tolerability and venous PK of repeat doses of orally inhaled nicotine delivered via the novel nicotine inhaler device at one dose level (0.67mg).

Part D:

A randomized, open-label, two-way crossover study to determine the venous PK of orally inhaled nicotine at one dose level (0.45mg) delivered via the novel nicotine inhaler device compared with the Nicorette® Inhalator (10mg). Three nicotine formulations were developed for assessment in this clinical study. The concentrations chosen were designed to encompass the doses likely to be acceptable to users. Given the delivered mass of formulation from the device (approximately 0.8g), the mid-strength formulation (0.056% wt/wt nicotine) would deliver 0.45mg, which is close to the dose delivered by the nicotine nasal spray[20]; concentrations above and below this would bracket this dose and explore tolerability and effect on craving. This study therefore assessed the novel nicotine inhaler device at three dose levels: 0.22, 0.45, and 0.67mg nicotine. The study (Australian New Zealand Clinical Trials Registry Number 343206) was approved by the Queensland Clinical Trials Network Inc. (Human Research Ethics Committee Number 2011003) and was conducted in accordance with the International Conference on Harmonisation Good Clinical Practice (GCP) guidelines. The study was performed at a single centre in Perth, Australia between January 9, 2012 and July 6, 2012 and all participants provided written informed consent prior to study start.

Participants

Healthy volunteers (male or female) aged 18–55 years were eligible for the study if they had smoked ≥10 manufactured cigarettes per day for the last year and smoked their first cigarette within 1hr of waking. Women of child-bearing potential were eligible only if they tested negative for pregnancy prior to study start and were using an accepted method of contraception. All subjects had an expired carbon monoxide level of >10 ppm at screening and were required to abstain from smoking for 12hr prior to their scheduled dosing time. Participants were excluded if they had a known or suspected history of hypersensitivity to nicotine or any other component of the inhaler. Participants were also excluded if they had a history of confirmed chronic and/or serious pulmonary disease, including asthma, or chronic obstructive pulmonary disease, a history of myocardial infarction or cerebrovascular accident, other clinically significant cardiac or renal conditions, or any comorbidity that could place them at risk or interfere with the interpretation of the study data. Women who were breastfeeding were excluded from the study.

Study Treatment

The novel nicotine inhaler device is the size and shape of a conventional cigarette and comprises a small, breath-operated valve that allows a user to self-titrate the inhalation. The rate at which nicotine is delivered from one charge of the inhaler device is therefore dependent on the number of “puffs” over which one charge (or “dose”) is inhaled and this, in turn, depends on an individual’s depth of inhalation. For most users, the device provides a comparable number of puffs to that of a conventional tobacco cigarette. The device can be refilled approximately 20 times via a pressurized canister that contains a formulation of pharmaceutical grade (free-base) nicotine formulated with propylene glycol, ethanol, saccharin, menthol, and HFA134a (CFC free) propellant. The canister forms an integral part of the storage container, which is similar in size to a pack of 20 cigarettes (Supplementary Figure S1). Participants were familiarized with the novel inhaler device using a placebo formulation on the day prior to receiving active treatment. The placebo formulation was identical to the active formulation with the exception of nicotine. Participants inhaled the entire contents of one charge of the new inhaler in a similar way to a cigarette. All participants were instructed to inhale at the same rate of one inhalation every 15 s over approximately 2min (i.e., approximately eight inhalations in total). The nicotine dose contained in 0.8g of formulation (a single dose/refill of the novel device) is estimated to be 0.22, 0.45, and 0.67mg for the 0.028%, 0.056%, and 0.084% wt/wt nicotine concentrations, respectively. The time when the participant took the first inhalation was recorded as the dose time (t = 0). Study participants were blinded to the dose of nicotine administered in each part of the study. In Part A of the study, each participant was randomly assigned to one of three groups. Participants in each group (n = 6) received two single doses of nicotine via the novel inhaler device on a single study day. Participants received doses at two of the three dose levels available via the novel inhaler device. The first group received a 0.22mg dose followed by a 0.45mg dose; the second group received a 0.22mg dose followed by a 0.67mg dose; and the third group received a 0.45mg dose followed by a 0.67mg dose. The first and second doses were separated by a washout period of at least 5.5hr (330min), but not more than 6.5hr (390min) on the study day. This ensured that the plasma nicotine from the first dose had reached baseline concentrations through excretion before the second dose was inhaled. In Part C, all participants received repeat doses of 0.67mg nicotine delivered via the novel inhaler device on the study day, with one complete refill of the device being inhaled every hour for 12hr.

Study Assessments

Pharmacokinetic Analysis

Plasma nicotine pharmacokinetic assessment was the primary outcome measure for this study. Approximately 4mL of whole blood was collected at each specified time point from an arterial line for Part A and a venous line for Part C. Plasma was separated by centrifugation within 30min of collection, aliquoted, and stored at ≤−70°C. Plasma nicotine concentrations in the range 1–50ng/mL were measured by liquid chromatography with tandem mass spectrometry, using a method validated for linearity, precision, and accuracy. Quality control samples at concentrations of 3.0, 7.5, and 37.5ng/mL, as well as 37.5ng/mL used as a dilute quality control for samples of low volume (diluted 1 in 2), were used to determine inter- and intra-precision and inter- and intra-accuracy. The mean inter-run accuracy was within 1% and precision was within 5%. For Part A, arterial plasma concentrations of nicotine were measured over time and derived pharmacokinetic parameters were summarized separately by dose level. The pharmacokinetic parameters determined were the mean maximum plasma nicotine concentration (C max), the median time to maximum plasma nicotine concentration (T max), and the mean area under the plasma concentration–time curve, from time zero to the end of the sample collection period (AUCall) and from time zero to the time of the last quantifiable concentration (AUClast), following administration using the novel inhaler device. Radial arterial blood sampling was performed 5min (±1min) preinhalation; at 2, 4, 6, 8, and 10min (±1min); at 15, 20, 40, and 60min (±2min); and at 120, 180, 240, and 300min (±5min) after the start of inhalation. The collection time of each blood sample was recorded. For Part C, pre- and postdose venous plasma concentrations of nicotine were measured by performing venous blood sampling at 5min (±5min) preinhalation and at 5min (±2min) after the start of inhalation, of each hourly dose. The collection time of each blood sample was recorded. Pharmacokinetic analyses were performed using Phoenix™ WinNonlin® Version 6.2 or higher.

Safety and Tolerability

For both Parts A and C, safety and tolerability were assessed by the study investigator. The incidence and nature of any adverse events (AEs) and any concomitant medicines from the start of the study until 8 days (±2 days) after the last administration were recorded by assessment of all spontaneously reported events and responses to neutral questioning, local tolerability, physical examination, and monitoring of vital signs (blood pressure, heart rate, respiration rate, and temperature). Tolerability of the orally inhaled nicotine was an assessment of symptoms resulting from inhalation of the nicotine by participants. Any symptoms that were reported as worse than prior to dosing were recorded as AEs. Local tolerability was an assessment of the contact area of the novel nicotine inhaler with the participant’s lips. Participants were asked how the device felt in their mouth or lips, which were also assessed visually. “Redness,” “swelling,” “stinging,” “tingling,” “numbness,” and “other symptoms” were recorded and assigned a severity of “none,” “mild,” “moderate,” or “severe.” For Part A, local tolerability was assessed at 20min predose and at 4min postdose. For Part C, local tolerability was assessed at 20min predose for the first dose only and at approximately 5min postdose for each dose.

Statistical Analyses

Statistical analyses were performed using SAS® Version 9.2 or higher. For Part A, participants were included in the pharmacokinetic population if they received all planned doses of nicotine, and descriptive statistics were used to summarize pharmacokinetic findings by dose level. For Part C, participants were included if they received all planned doses up to and including the fourth hourly dose, and all blood sampling up to 5min following the fourth hourly dose. Pharmacokinetic concentrations were presented by time for each dose. Participants were included in the safety intent-to-treat population if they received one dose of nicotine.

Results

Study Population

In Part A, 18 participants were randomly assigned to one of three groups (n = 6 per group), and each participant received two single doses of nicotine via the novel inhaler device at two dose levels. A further 18 participants were assigned to Part C and received repeat doses of nicotine at one dose level. Baseline demographics of the participants are shown in Supplementary Table S1.

Part A

All participants were included in the pharmacokinetic analysis. The mean (SD) weights of formulation inhaled from the novel nicotine inhaler device were 0.8340 (0.1092), 0.8579 (0.1098), and 0.7935 (0.1642) g, corresponding to an overall mean 0.2335, 0.4804, and 0.6665mg nicotine, for the 0.22, 0.45, and 0.67mg nicotine dose levels, respectively. The range of weights of formulation inhaled from the novel inhaler device were 0.6633–1.0803, 0.6936–1.0369, and 0.4224–0.9892g, for the 0.22, 0.45, and 0.67mg nicotine dose levels, corresponding to ranges of 0.1857–0.3025, 0.3884–0.5807, and 0.3548–0.8309mg nicotine, respectively.

Part C

All participants were included in the pharmacokinetic analysis. The mean (SD) weight of formulation inhaled from the novel nicotine inhaler device 0.67mg was 0.8424 (0.2051) g, corresponding to an overall mean 0.7076mg nicotine administered each hour for 12hr. The weights of formulation inhaled were in the range of 0.1588–1.1991g between participants, which corresponded to a range of 0.1334–1.007mg nicotine.

Study Assessments: Pharmacokinetic Analysis

Arterial PK of a Single Nicotine Dose (Part A)

The mean arterial plasma nicotine level rose sharply following administration of each of the three doses of nicotine using the novel inhaler device. Nicotine was detected in arterial blood at the first postinhalation sampling time point (at 2min after the start of inhalation); the mean (SD) arterial plasma nicotine concentrations at 2min postinhalation were 1.10 (0.78), 2.06 (0.92), and 2.59 (1.18) ng/mL for the 0.22, 0.45, and 0.67mg doses, respectively (Figure 1). The postdose arterial plasma nicotine level had fallen to below the lower limit of quantification (1.00ng/mL) in most participants by 120, 180, and 360min for the 0.22, 0.45, and 0.67mg doses, respectively.
Figure 1.

Mean arterial plasma nicotine concentration by treatment (linear scale): Part A (N = 18)* up to 120min after single administration of the novel nicotine inhaler device. SEM = standard error of the mean.

Mean arterial plasma nicotine concentration by treatment (linear scale): Part A (N = 18)* up to 120min after single administration of the novel nicotine inhaler device. SEM = standard error of the mean. *Participants in each group (n = 6 per group) received two single doses of nicotine (a single dose at two of the three dose levels). Insufficient data were available over the validated range of plasma nicotine concentration (1–50ng/mL) to allow accurate determination of arterial plasma nicotine half life. The highest mean (SD) arterial plasma nicotine concentrations recorded at the study time points were 1.99 (0.62) ng/mL at 8min for the 0.22mg dose, and 3.66 (1.17) and 4.23 (1.14) ng/mL at 6min for both 0.45 and 0.67mg doses, respectively. Mean (SD) arterial C max following administration of the novel nicotine inhaler device 0.22, 0.45, and 0.67mg were 2.113 (0.671), 3.733 (1.131), and 4.380 (1.186) ng/mL, respectively (Table 1). Similarly, mean AUClast and AUCall were higher with increasing doses of nicotine. In contrast, median (range) arterial T max decreased with increasing nicotine doses (Table 1).
Table 1.

Summary of Arterial Pharmacokinetic Parameters by Treatment: Part A

Nicotine inhaler deviceNicotine inhaler deviceNicotine inhaler device
0.22 mg0.45 mg0.67 mg
C max, ng/mL2.113 (0.671)3.733 (1.131)4.380 (1.186)
T max, median (range), min10.0 (6.0–20.0a)7.0 (6.0–10.0)6.0 (4.0–10.0)
AUClast, min·ng/mL118.6 (127.3)241.7 (152.6)296.9 (124.6)
AUCall, min·ng/mL145.7 (132.5)274.4 (146.5)334.4 (124.2)

All values are mean (SD) unless stated otherwise. AUCall = area under the plasma concentration–time curve from time zero to the end of the sample collection period; AUClast = area under the concentration–time curve from time zero to the time of the last quantifiable concentration; C max = maximum plasma nicotine concentration; T max = time to maximum plasma nicotine concentration.

a T max was in the range 6.0–10.0min for 10 participants. T max values of 15 and 20min were observed in the remaining two participants.

Summary of Arterial Pharmacokinetic Parameters by Treatment: Part A All values are mean (SD) unless stated otherwise. AUCall = area under the plasma concentration–time curve from time zero to the end of the sample collection period; AUClast = area under the concentration–time curve from time zero to the time of the last quantifiable concentration; C max = maximum plasma nicotine concentration; T max = time to maximum plasma nicotine concentration. a T max was in the range 6.0–10.0min for 10 participants. T max values of 15 and 20min were observed in the remaining two participants. Comparison of arterial mean plasma nicotine concentrations in Part A with venous mean plasma nicotine concentrations in Part B (reported elsewhere [Moyses et al.[19]]), following administration of a single dose of 0.45mg nicotine via the novel inhaler device (Figure 2), suggests that an early peak arterial plasma nicotine concentration is followed by a peak in venous plasma nicotine concentration. The venous plasma nicotine concentration in Part B is seen to continue to be higher than the arterial plasma nicotine concentration in Part A for the remainder of the postdose period.
Figure 2.

Comparison of mean arterial versus venous plasma nicotine concentrations over time after a single administration of the nicotine inhaler device 0.45mg (linear scale) in Parts A (N = 18)* and B† (N = 24). SEM = standard error of the mean.

Comparison of mean arterial versus venous plasma nicotine concentrations over time after a single administration of the nicotine inhaler device 0.45mg (linear scale) in Parts A (N = 18)* and B† (N = 24). SEM = standard error of the mean. *Participants in each group (n = 6 per group) received two single doses of nicotine (a single dose at two of the three dose levels). Participants received one single dose of nicotine at 0.45mg. Data from Part B are reported elsewhere.[19]

Venous PK of Repeated Nicotine Doses (Part C)

The mean pre- and postdose venous plasma nicotine concentrations increased steadily throughout the 12-hr dosing period in Part C of the study and appeared to approach a steady state oscillation between approximately 8 and 10ng/mL at the later time points (after 9hr) (Figure 3). The highest mean (SD) pre- and postdose venous plasma nicotine concentrations were measured at dose 11—i.e., 8.31 (3.05) and 10.40 (3.68) ng/mL, respectively.
Figure 3.

Mean venous plasma nicotine concentration over time (linear scale): Part C (N = 18) after repeated administration of the novel nicotine inhaler device (0.67mg). SEM = standard error of the mean.

Mean venous plasma nicotine concentration over time (linear scale): Part C (N = 18) after repeated administration of the novel nicotine inhaler device (0.67mg). SEM = standard error of the mean.

Safety and Tolerability

A total of 56 treatment-emergent AEs (TEAEs) were reported by 16 (89%) participants. Of these, 47 were considered as related to study medication. The most common TEAEs related to the study medication were oral paraesthesia, throat irritation, headache, dizziness, dry throat, and cough (Supplementary Table S2). There were 27 reports of local tolerability symptoms; all were reported as mild, with tingling the most commonly reported symptom (12/18 participants). Two TEAEs were assessed as moderate, one of which was assessed as related to study medication (tingling of the lips and tongue, which was reported immediately after administration of 0.67mg of nicotine via the novel device and resolved within 9min). A total of 104 TEAEs were reported by 17 (94%) participants. Of these, 97 were considered as related to the novel inhaler device and the most commonly reported were oral paraesthesia, throat irritation, and headache (Supplementary Table S2). One participant reported mild stinging 5min postdose following administration of the first three doses of nicotine via the novel device. There were 34 (16%) reports of mild tingling and 14 (6%) reports of mild numbness. Two TEAEs were assessed as moderate, one of which was assessed as related to study medication (emesis, which was reported 20min after the 11th hourly administration of 0.67mg nicotine via the novel device and resolved within 1hr). There were no AEs reported as severe, no serious AEs, or deaths throughout the study and no participants discontinued treatment owing to an AE. There were no clinically significant changes in mean vital signs over time for the duration of the study. In Part A, one participant exhibited a change at the physical examination (decreased sensation in the right little finger and palm) which was assessed as clinically significant but considered to be a non-TEAE as it occurred before the first dose.

Discussion

We present data from two parts of a four-part clinical study assessing a novel nicotine inhaler device. We studied both the arterial PK of a single dose of nicotine at three dose levels (Part A) and the venous PK of repeat doses of nicotine (Part C). The results indicate that nicotine rapidly enters the systemic circulation following administration using the novel inhaler device and that repeated hourly inhalations lead to an increasing venous plasma nicotine concentration that approaches a steady state oscillation after 9hr. In Part A of the study, arterial blood sampling times enabled the pharmacokinetic profile of nicotine administered using the novel inhaler device to be clearly defined. The mean arterial plasma concentration rose sharply following administration of each of the three doses of nicotine with the presence of nicotine detected in arterial blood at the first sampling time point (at 2min) after the start of inhalation (which took approximately 2min to complete). For the 0.45mg dose, the mean arterial nicotine plasma level of 2.06ng/mL recorded at 2min was over half the subsequent C max. The speed at which nicotine was apparent in arterial blood suggests that there was a degree of pulmonary absorption with the novel inhaler device as oromucosal delivery alone results in a significantly slower rise in plasma nicotine concentration.[7] Mean arterial nicotine plasma C max increased from 2.113 to 4.380ng/mL with an increase in nicotine dose from 0.22 to 0.67mg. The increase in C max was accompanied by a corresponding decrease in median T max (from 10.0 to 6.0min). The median arterial T max for the 0.67mg nicotine dose was similar to that reported for 1.0mg nicotine delivered via a nasal spray (6.0 vs. 5.0min, respectively),[21] where the difference may reflect the bolus regimen used with the nicotine nasal spray. AUCall values ranged from 145.7 to 334.4 min·ng/mL, possibly due to the variability in individual patterns of inhalation within the study dosing regimen of one puff every 15 s. The lack of observed dose proportionality between the 0.45 and 0.67mg doses could be due to variation in the depths of inhalation between individuals and with different strengths. Such observations have been reported previously and are thought to be due to increased throat scratch experienced with inhalation of nicotine at higher concentrations.[22] In Part C of the study, both the pre- and postdose venous plasma nicotine concentrations increased steadily throughout the 12-hr dosing period. The highest pre- and postdose plasma nicotine concentrations were measured at dose 11 of the 12 doses administered. Venous plasma nicotine concentrations after repeat dosing of 0.67mg nicotine (Part C) appeared to be more variable than arterial concentrations after single dosing (Part A). The cumulative effect of repeatedly dosing before venous plasma nicotine concentrations had returned to baseline is likely to have contributed to the observed variation. Following hourly administration of 0.67mg of nicotine using the novel inhaler device, venous plasma nicotine concentrations appeared to approach a steady state oscillation between approximately 8 and 10ng/mL at the later time points of the study. This is considerably lower than the range of venous plasma nicotine concentration recorded after smoking a cigarette containing 1.2mg nicotine every hour (approximately 20–50ng/mL).[23] The qualitative pharmacokinetic profile of the novel device is similar to that of a cigarette with higher, earlier peak arterial concentrations relative to venous levels, although at lower absolute nicotine concentrations than seen with a cigarette. This is in contrast to pharmacokinetic data on the Nicorette® nicotine inhaler, which shows an earlier venous peak and a low, delayed arterial peak consistent with predominantly nonpulmonary delivery.[24] Hence, the closer pharmacokinetic surrogacy of the novel device may translate into greater acceptability and efficacy relative to currently available NRT products, although this will require confirmation from randomized efficacy trials. A variety of electronic cigarettes are also available, which utilize electrical heating to vaporize nicotine for inhalation. Pharmacokinetic studies of electronic cigarette-naive populations have shown very low levels of systemic nicotine,[14] although a small study of experienced users with electronic cigarettes carrying increased voltage and higher concentration nicotine solutions demonstrated that PK comparable with those of cigarettes are obtainable.[17] With the achievement of a similar profile in a device-naive population in the current study, it is plausible that the novel device may have broader efficacy than standard, widely available, electronic cigarettes. This was a small, short-duration study that was not designed to fully evaluate safety. However, reports of AEs were recorded systematically and the trial was conducted according to GCP. Administration of nicotine via the novel device was well tolerated by the participants in both study parts and the TEAEs reported were consistent with those reported in a previous study.[25] There were no severe or serious AEs, and no subjects discontinued treatment owing to an AE. The majority of local AEs were mild in nature. However, the safety profile of the novel nicotine inhaler will need to be confirmed in larger, longer term trials. The comparison of arterial and venous plasma nicotine concentrations following administration of a single dose of 0.45mg nicotine via the novel inhaler device in Parts A and B, respectively (Figure 2), is derived from results from different participants. Analysis of results from simultaneous arterial and venous blood samples from the same participants would provide more accurate information. Furthermore, the novel inhaler utilizes a breath-actuated valve and the quantity of nicotine inhaled may have varied between users. The precise pattern of nicotine delivery and absorption using the novel inhaler device would require confirmation in further studies using labeled nicotine. An additional limitation of the study was highlighted on comparison of the mean venous plasma nicotine concentrations delivered from the novel inhaler device 0.45mg in Parts B and D. The plasma nicotine concentration curves were very similar; however, the peak nicotine concentration in Part D was 3.52ng/mL compared with 3.28ng/mL in Part B. Although the device was primed before use in all study parts, it was thought that administration of the fourth dose from the device in Part D allowed greater saturation of the wick compared with administration of the first dose in Part B and consequently delivered a higher dose of nicotine than in Part B. This first-dose anomaly was regarded as consistent across the three strengths of formulation used. The administration of a single dose and repeat doses from the novel inhaler device in Part A and Part C, respectively, may have resulted in lower plasma concentrations of nicotine being achieved in Part A than Part C.

Conclusions

The data indicate that nicotine is rapidly delivered into the systemic circulation following inhalation using the novel inhaler device with an arterial pharmacokinetic profile consistent with a degree of pulmonary absorption. The novel nicotine inhaler device is comparable with a cigarette both in appearance and mode of use. It offers a rapid nicotine delivery that is as fast as the nicotine nasal spray but offers the possibility of improved tolerability. It has the potential to address many behavioral and sensorial aspects of smoking that can make quitting difficult, and it is also likely to be of considerable interest in a tobacco harm reduction approach to smoking.

Supplementary Material

Supplementary Tables S1 and S2 and Figure S1 can be found online at http://www.ntr.oxfordjournals.org

Funding

This study was supported by Kind Consumer Limited, London, UK. Nicoventures Limited, London, UK provided development funding in return for the license to the final product. Nicoventures is part of the British American Tobacco Group but is separate from the tobacco businesses.

Declaration of interests

CM and AH are employees of Kind Consumer Limited. AR has no conflicts of interest to disclose.
  15 in total

1.  Variability among electronic cigarettes in the pressure drop, airflow rate, and aerosol production.

Authors:  Monique Williams; Prue Talbot
Journal:  Nicotine Tob Res       Date:  2011-10-12       Impact factor: 4.244

2.  A clinical laboratory model for evaluating the acute effects of electronic "cigarettes": nicotine delivery profile and cardiovascular and subjective effects.

Authors:  Andrea R Vansickel; Caroline O Cobb; Michael F Weaver; Thomas E Eissenberg
Journal:  Cancer Epidemiol Biomarkers Prev       Date:  2010-07-20       Impact factor: 4.254

Review 3.  Nicotine and nonnicotine factors in cigarette addiction.

Authors:  Jed E Rose
Journal:  Psychopharmacology (Berl)       Date:  2005-12-16       Impact factor: 4.530

4.  Higher levels of nicotine in arterial than in venous blood after cigarette smoking.

Authors:  J E Henningfield; J M Stapleton; N L Benowitz; R F Grayson; E D London
Journal:  Drug Alcohol Depend       Date:  1993-06       Impact factor: 4.492

5.  Effect of an electronic nicotine delivery device (e cigarette) on desire to smoke and withdrawal, user preferences and nicotine delivery: randomised cross-over trial.

Authors:  C Bullen; H McRobbie; S Thornley; M Glover; R Lin; M Laugesen
Journal:  Tob Control       Date:  2010-04       Impact factor: 7.552

6.  Site of nicotine absorption from a vapour inhaler--comparison with cigarette smoking.

Authors:  E Lunell; L Molander; K Ekberg; J Wahren
Journal:  Eur J Clin Pharmacol       Date:  2000-01       Impact factor: 2.953

7.  Plasma nicotine levels after cigarette smoking and chewing nicotine gum.

Authors:  M A Russell; C Feyerabend; P V Cole
Journal:  Br Med J       Date:  1976-05-01

8.  Arteriovenous differences in plasma concentration of nicotine and catecholamines and related cardiovascular effects after smoking, nicotine nasal spray, and intravenous nicotine.

Authors:  S G Gourlay; N L Benowitz
Journal:  Clin Pharmacol Ther       Date:  1997-10       Impact factor: 6.875

9.  A pilot study of nicotine delivery to smokers from a metered-dose inhaler.

Authors:  Brent Caldwell; Stuart Dickson; Carl Burgess; Robert Siebers; Sima Mala; Adrienne Parkes; Julian Crane
Journal:  Nicotine Tob Res       Date:  2009-04-03       Impact factor: 4.244

10.  Evaluation of a novel nicotine inhaler device: part 2--effect on craving and smoking urges.

Authors:  Chris Moyses; Alex Hearn; Andrew Redfern
Journal:  Nicotine Tob Res       Date:  2014-07-31       Impact factor: 4.244

View more
  1 in total

Review 1.  Impact of Nicotine Replacement and Electronic Nicotine Delivery Systems on Fetal Brain Development.

Authors:  Sebastian Sailer; Giorgia Sebastiani; Vicente Andreu-Férnández; Oscar García-Algar
Journal:  Int J Environ Res Public Health       Date:  2019-12-14       Impact factor: 3.390

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.