Literature DB >> 25384349

Can ambulatory blood pressure monitoring detect early diastolic dysfunction in children with type 1 diabetes mellitus: correlations with B-type natriuretic peptide and tissue Doppler findings.

Mustafa Kır1, Benhur Cetin2, Korcan Demir3, Nuh Yılmaz1, Ozgur Kızılca1, Tulay Demircan1, Nurettin Unal1, Ece Bober3, Gul Sagin Saylam1.   

Abstract

AIM: To evaluate the relationship between 24-h blood pressure (BP) measurements and diastolic heart function evaluated by Doppler tissue imaging and B-type natriuretic peptide (BNP) levels in children with type 1 diabetes mellitus (DM). PATIENTS AND METHODS: A total of 32 diabetic and 18 healthy children were enrolled. Spectral Doppler analysis and tissue Doppler measurements were performed by conventional echocardiography. The 24-h ambulatory BP and serum BNP levels were measured.
RESULTS: Analysis of ambulatory blood pressure monitoring (ABPM) recordings showed that median daytime diastolic BP load were significantly higher in diabetic patients compared to controls [12.35 (4.23-27.23) vs. 2.5 (0-8.7), p = 0.007]. Patients with elevated daytime systolic and diastolic BP loads had significantly higher BNP values compared to patients with normal BP load (31.4 ± 24.36 vs. 11.84 ± 11.25 pg/mL, p = 0.03 and 23.21 ± 15.12 vs. 12.12 ± 14.65 pg/mL, p = 0.03, respectively). Isovolemic contraction time (47.43 ± 7.84 vs. 42.27 ± 7.47, p = 0.045), isovolemic relaxation time (68.84 ± 10.43 vs. 58.77 ± 10.02, p = 0.02), and myocardial performance index (0.45 ± 0.10 vs. 0.37 ± 0.09, p = 0.02) as determined by tissue Doppler echocardiography were significantly high in diabetic patients compared to that of control cases. Ratio of mitral peak early diastolic flow velocity (E) to peak early diastolic myocardial velocities by tissue Doppler echocardiography (E') was also higher in patients with elevated daytime systolic BP load (E/E', 6.71 ± 1.97 vs. 4.91 ± 1.02, p = 0.04).
CONCLUSION: Elevated BP loads detected by 24-h ambulatory BP measurements in children with type 1 diabetes are associated with increased BNP levels and abnormal tissue Doppler echocardiography indices, indicating early stage cardiac dysfunction.
© 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

Entities:  

Keywords:  ambulatory blood pressure; diabetic children; diastolic function

Mesh:

Substances:

Year:  2014        PMID: 25384349     DOI: 10.1111/pedi.12234

Source DB:  PubMed          Journal:  Pediatr Diabetes        ISSN: 1399-543X            Impact factor:   4.866


  4 in total

Review 1.  Ambulatory Blood Pressure Monitoring in Pediatrics.

Authors:  Sonali S Patel; Stephen R Daniels
Journal:  Curr Hypertens Rep       Date:  2019-07-26       Impact factor: 5.369

Review 2.  Ambulatory Blood Pressure Monitoring in Children and Adolescents: a Review of Recent Literature and New Guidelines.

Authors:  Ian Macumber
Journal:  Curr Hypertens Rep       Date:  2017-10-25       Impact factor: 5.369

3.  Technological Ecological Momentary Assessment Tools to Study Type 1 Diabetes in Youth: Viewpoint of Methodologies.

Authors:  Mary Katherine Ray; Alana McMichael; Maria Rivera-Santana; Jacob Noel; Tamara Hershey
Journal:  JMIR Diabetes       Date:  2021-06-03

Review 4.  The Impact of Diabetes Mellitus on Cardiovascular Risk Onset in Children and Adolescents.

Authors:  Ida Pastore; Andrea Mario Bolla; Laura Montefusco; Maria Elena Lunati; Antonio Rossi; Emma Assi; Gian Vincenzo Zuccotti; Paolo Fiorina
Journal:  Int J Mol Sci       Date:  2020-07-12       Impact factor: 5.923

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.