| Literature DB >> 25383351 |
Sung-Ae Son1, Hyoung-Mee Roh1, Bock Hur1, Yong-Hoon Kwon2, Jeong-Kil Park1.
Abstract
OBJECTIVES: This study examined the influence of the resin thickness on the polymerization of silorane- and methacrylate-based composites.Entities:
Keywords: Polymerization; Resin thickness; Silorane-based composite resin
Year: 2014 PMID: 25383351 PMCID: PMC4223102 DOI: 10.5395/rde.2014.39.4.310
Source DB: PubMed Journal: Restor Dent Endod ISSN: 2234-7658
Composition of composite resins tested in the study
P90, Filtek P90; Z250, Filtek Z250; Z350, Filtek Z350.
Bis-GMA, bisphenol A glycidyl methacrylate; Bis-EMA, ethoxylatedbisphenol A glycidyl methacrylate; TEGDMA, triethylene glycol dimethacrylate; UDMA, urethane dimethacrylate.
Number of photons detected in the composite resins of different thicknesses (Mean ± SD) and attenuation coefficient (µ, mm-1) according to the exponential curve fit
P90, Filtek P90; Z250, Filtek Z250; Z350, Filtek Z350.
SD, standard deviation.
Degree of conversion (DC, %) of composite resins at different depths (Mean ± SD)
P90, Filtek P90; Z250, Filtek Z250; Z350, Filtek Z350.
SD, standard deviation.
*Statistically significant difference on resin product is shown by uppercase superscript letters, for different thicknesses by lowercase superscript letters. Same letters or numbers are not significantly different (p > 0.05).
Vickers microhardness (Hv) of composite resins at different depths (Mean ± SD)
P90, Filtek P90; Z250, Filtek Z250; Z350, Filtek Z350.
SD, standard deviation.
*Statistically significant difference on resin product is shown by uppercase superscript letters, for different thicknesses by lowercase superscript letters. Same letters or numbers are not significantly different (p > 0.05).
Polymerization shrinkage (µm) of composite resins for different thicknesses (Mean ± SD)
P90, Filtek P90; Z250, Filtek Z250; Z350, Filtek Z350.
SD, standard deviation.
*Statistically significant difference on resin product is shown by uppercase superscript letters, for different thicknesses by lowercase superscript letters. Same letters or numbers are not significantly different (p > 0.05).
Refractive index of composite resins at different depths (Mean ± SD)
P90, Filtek P90; Z250, Filtek Z250; Z350, Filtek Z350.
SD, standard deviation.
*Statistically significant difference on resin product is shown by uppercase superscript letters, for different thicknesses by lowercase superscript letters. Same letters or numbers are not significantly different (p > 0.05).
Figure 1Correlation between the degree of conversion and Vickers microhardness values for different depths.
Figure 2Correlation between the degree of conversion and refractive index values for different depths.
Figure 3Correlation between the Vickers microhardness and refractive index values for different depths and resin products.