Optimization of noise in non-integrated instrumentation amplifier for the amplification of very low electrophysiological [corrected] signals. Case of electro cardio graphic signals (ECG).

Guy Merlin Ngounou1, Martin Kom.   

Abstract

In this paper we present an instrumentation amplifier with discrete elements and optimized noise for the amplification of very low signals. In amplifying signals of very weak amplitude, the noise can completely absorb these signals if the used amplifier does not present the optimal guarantee to minimize the noise. Based on related research and re-viewing of recent patents Journal of Medical Systems, 30:205-209, 2006, we suggest an approach of noise reduction in amplification much more thoroughly than re-viewing of recent patents and we deduce from it the general criteria necessary and essential to achieve this optimization. The comparison of these criteria with the provisions adopted in practice leads to the inadequacy of conventional amplifiers for effective noise reduction. The amplifier we propose is an instrumentation amplifier with active negative feedback and optimized noise for the amplification of signals with very low amplitude. The application of this method in the case of electro cardio graphic signals (ECG) provides simulation results fully in line with forecasts.

Entities:  

Mesh:

Year:  2014        PMID: 25381049     DOI: 10.1007/s10916-014-0152-8

Source DB:  PubMed          Journal:  J Med Syst        ISSN: 0148-5598            Impact factor:   4.460


  4 in total

1.  ECG/PPG integer signal processing for a ubiquitous health monitoring system.

Authors:  Woosik Shin; Yong Dae Cha; Gilwon Yoon
Journal:  J Med Syst       Date:  2009-05-13       Impact factor: 4.460

2.  EEG signal analysis: a survey.

Authors:  D Puthankattil Subha; Paul K Joseph; Rajendra Acharya U; Choo Min Lim
Journal:  J Med Syst       Date:  2010-04       Impact factor: 4.460

3.  Ideal filtering approach on DCT domain for biomedical signals: index blocked DCT filtering method (IB-DCTFM).

Authors:  Hang Sik Shin; Chungkeun Lee; Myoungho Lee
Journal:  J Med Syst       Date:  2009-04-30       Impact factor: 4.460

4.  Low-cost compact ECG with graphic LCD and phonocardiogram system design.

Authors:  Sadik Kara; Semra Kemaloğlu; Samil Kirbaş
Journal:  J Med Syst       Date:  2006-06       Impact factor: 4.920

  4 in total
  1 in total

1.  FPGA Implementation of Heart Rate Monitoring System.

Authors:  D Panigrahy; M Rakshit; P K Sahu
Journal:  J Med Syst       Date:  2015-12-07       Impact factor: 4.460

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.