PURPOSE: To develop a quality assurance (QA) workflow by using a robust, curated, manually segmented anatomic region-of-interest (ROI) library as a benchmark for quantitative assessment of different image registration techniques used for head and neck radiation therapy-simulation computed tomography (CT) with diagnostic CT coregistration. MATERIALS AND METHODS: Radiation therapy-simulation CT images and diagnostic CT images in 20 patients with head and neck squamous cell carcinoma treated with curative-intent intensity-modulated radiation therapy between August 2011 and May 2012 were retrospectively retrieved with institutional review board approval. Sixty-eight reference anatomic ROIs with gross tumor and nodal targets were then manually contoured on images from each examination. Diagnostic CT images were registered with simulation CT images rigidly and by using four deformable image registration (DIR) algorithms: atlas based, B-spline, demons, and optical flow. The resultant deformed ROIs were compared with manually contoured reference ROIs by using similarity coefficient metrics (ie, Dice similarity coefficient) and surface distance metrics (ie, 95% maximum Hausdorff distance). The nonparametric Steel test with control was used to compare different DIR algorithms with rigid image registration (RIR) by using the post hoc Wilcoxon signed-rank test for stratified metric comparison. RESULTS: A total of 2720 anatomic and 50 tumor and nodal ROIs were delineated. All DIR algorithms showed improved performance over RIR for anatomic and target ROI conformance, as shown for most comparison metrics (Steel test, P < .008 after Bonferroni correction). The performance of different algorithms varied substantially with stratification by specific anatomic structures or category and simulation CT section thickness. CONCLUSION: Development of a formal ROI-based QA workflow for registration assessment demonstrated improved performance with DIR techniques over RIR. After QA, DIR implementation should be the standard for head and neck diagnostic CT and simulation CT allineation, especially for target delineation.
PURPOSE: To develop a quality assurance (QA) workflow by using a robust, curated, manually segmented anatomic region-of-interest (ROI) library as a benchmark for quantitative assessment of different image registration techniques used for head and neck radiation therapy-simulation computed tomography (CT) with diagnostic CT coregistration. MATERIALS AND METHODS: Radiation therapy-simulation CT images and diagnostic CT images in 20 patients with head and neck squamous cell carcinoma treated with curative-intent intensity-modulated radiation therapy between August 2011 and May 2012 were retrospectively retrieved with institutional review board approval. Sixty-eight reference anatomic ROIs with gross tumor and nodal targets were then manually contoured on images from each examination. Diagnostic CT images were registered with simulation CT images rigidly and by using four deformable image registration (DIR) algorithms: atlas based, B-spline, demons, and optical flow. The resultant deformed ROIs were compared with manually contoured reference ROIs by using similarity coefficient metrics (ie, Dice similarity coefficient) and surface distance metrics (ie, 95% maximum Hausdorff distance). The nonparametric Steel test with control was used to compare different DIR algorithms with rigid image registration (RIR) by using the post hoc Wilcoxon signed-rank test for stratified metric comparison. RESULTS: A total of 2720 anatomic and 50 tumor and nodal ROIs were delineated. All DIR algorithms showed improved performance over RIR for anatomic and target ROI conformance, as shown for most comparison metrics (Steel test, P < .008 after Bonferroni correction). The performance of different algorithms varied substantially with stratification by specific anatomic structures or category and simulation CT section thickness. CONCLUSION: Development of a formal ROI-based QA workflow for registration assessment demonstrated improved performance with DIR techniques over RIR. After QA, DIR implementation should be the standard for head and neck diagnostic CT and simulation CT allineation, especially for target delineation.
Authors: Terry S Yoo; Michael J Ackerman; William E Lorensen; Will Schroeder; Vikram Chalana; Stephen Aylward; Dimitris Metaxas; Ross Whitaker Journal: Stud Health Technol Inform Date: 2002
Authors: Xiao Han; Mischa S Hoogeman; Peter C Levendag; Lyndon S Hibbard; David N Teguh; Peter Voet; Andrew C Cowen; Theresa K Wolf Journal: Med Image Comput Comput Assist Interv Date: 2008
Authors: Jayashree Kalpathy-Cramer; Musaddiq Awan; Steven Bedrick; Coen R N Rasch; David I Rosenthal; Clifton D Fuller Journal: J Digit Imaging Date: 2014-02 Impact factor: 4.056
Authors: Musaddiq Awan; Jayashree Kalpathy-Cramer; G Brandon Gunn; Beth M Beadle; Adam S Garden; Jack Phan; Emma Holliday; William E Jones; Elizabeth Maani; Abhilasha Patel; Jehee Choi; Virginia Clyburn; Bundhit Tantiwongkosi; David I Rosenthal; Clifton D Fuller Journal: Pract Radiat Oncol Date: 2012-12-21
Authors: He Wang; Lei Dong; Jennifer O'Daniel; Radhe Mohan; Adam S Garden; K Kian Ang; Deborah A Kuban; Mark Bonnen; Joe Y Chang; Rex Cheung Journal: Phys Med Biol Date: 2005-06-01 Impact factor: 3.609
Authors: Nicholas Hardcastle; Wolfgang A Tomé; Donald M Cannon; Charlotte L Brouwer; Paul W H Wittendorp; Nesrin Dogan; Matthias Guckenberger; Stéphane Allaire; Yogish Mallya; Prashant Kumar; Markus Oechsner; Anne Richter; Shiyu Song; Michael Myers; Bülent Polat; Karl Bzdusek Journal: Radiat Oncol Date: 2012-06-15 Impact factor: 3.481
Authors: Rob H Ireland; Karen E Dyker; David C Barber; Steven M Wood; Michael B Hanney; Wendy B Tindale; Neil Woodhouse; Nigel Hoggard; John Conway; Martin H Robinson Journal: Int J Radiat Oncol Biol Phys Date: 2007-04-18 Impact factor: 7.038
Authors: Abdallah S R Mohamed; Carlos E Cardenas; Adam S Garden; Musaddiq J Awan; Crosby D Rock; Sarah A Westergaard; G Brandon Gunn; Abdelaziz M Belal; Ahmed G El-Gowily; Stephen Y Lai; David I Rosenthal; Clifton D Fuller; Michalis Aristophanous Journal: Radiother Oncol Date: 2017-07-31 Impact factor: 6.280
Authors: Andrew Wentzel; Peter Hanula; Lisanne V van Dijk; Baher Elgohari; Abdallah S R Mohamed; Carlos E Cardenas; Clifton D Fuller; David M Vock; Guadalupe Canahuate; G E Marai Journal: Radiother Oncol Date: 2020-05-16 Impact factor: 6.280
Authors: Rachel B Ger; Jinzhong Yang; Yao Ding; Megan C Jacobsen; Clifton D Fuller; Rebecca M Howell; Heng Li; R Jason Stafford; Shouhao Zhou; Laurence E Court Journal: Med Phys Date: 2017-07-18 Impact factor: 4.071
Authors: G Brandon Gunn; Pierre Blanchard; Adam S Garden; X Ronald Zhu; C David Fuller; Abdallah S Mohamed; William H Morrison; Jack Phan; Beth M Beadle; Heath D Skinner; Erich M Sturgis; Merrill S Kies; Kate A Hutcheson; David I Rosenthal; Radhe Mohan; Michael T Gillin; Steven J Frank Journal: Int J Radiat Oncol Biol Phys Date: 2016-02-12 Impact factor: 7.038
Authors: Pierre Blanchard; Andrew J Wong; G Brandon Gunn; Adam S Garden; Abdallah S R Mohamed; David I Rosenthal; Joseph Crutison; Richard Wu; Xiaodong Zhang; X Ronald Zhu; Radhe Mohan; Mayankkumar V Amin; C David Fuller; Steven J Frank Journal: Radiother Oncol Date: 2016-09-15 Impact factor: 6.280
Authors: Jay A Messer; Abdallah S R Mohamed; Katherine A Hutcheson; Yao Ding; Jan S Lewin; Jihong Wang; Stephen Y Lai; Steven J Frank; Adam S Garden; Vlad Sandulache; Hillary Eichelberger; Chloe C French; Rivka R Colen; Jack Phan; Jayashree Kalpathy-Cramer; John D Hazle; David I Rosenthal; G Brandon Gunn; Clifton D Fuller Journal: Radiother Oncol Date: 2016-01-28 Impact factor: 6.280
Authors: Richard Y Wu; Amy Y Liu; Terence T Sio; Pierre Blanchard; Cody Wages; Mayankkumar V Amin; Gary B Gunn; Uwe Titt; Rong Ye; Kazumichi Suzuki; Michael T Gillin; Xiaorong R Zhu; Radhe Mohan; Steven J Frank Journal: Int J Part Ther Date: 2017-12-28