Literature DB >> 25380111

Frameless robotic stereotactic biopsies: a consecutive series of 100 cases.

Michel Lefranc1, Cyrille Capel, Anne-Sophie Pruvot-Occean, Anthony Fichten, Christine Desenclos, Patrick Toussaint, Daniel Le Gars, Johann Peltier.   

Abstract

OBJECT: Stereotactic biopsy procedures are an everyday part of neurosurgery. The procedure provides an accurate histological diagnosis with the least possible morbidity. Robotic stereotactic biopsy needs to be an accurate, safe, frameless, and rapid technique. This article reports the clinical results of a series of 100 frameless robotic biopsies using a Medtech ROSA device.
METHODS: The authors retrospectively analyzed their first 100 frameless stereotactic biopsies performed with the robotic ROSA device: 84 biopsies were performed by frameless robotic surface registration, 7 were performed by robotic bone fiducial marker registration, and 9 were performed by scalp fiducial marker registration. Intraoperative flat-panel CT scanning was performed concomitantly in 25 cases. The operative details of the robotic biopsies, the diagnostic yield, and mortality and morbidity data observed in this series are reported.
RESULTS: A histological diagnosis was established in 97 patients. No deaths or permanent morbidity related to surgery were observed. Six patients experienced transient neurological worsening. Six cases of bleeding within the lesion or along the biopsy trajectory were observed on postoperative CT scans but were associated with transient clinical symptoms in only 2 cases. Stereotactic surgery was performed with patients in the supine position in 93 cases and in the prone position in 7 cases. The use of fiducial markers was reserved for posterior fossa biopsy via a transcerebellar approach, via an occipital approach, or for pediatric biopsy.
CONCLUSIONS: ROSA frameless stereotactic biopsies appear to be accurate and safe robotized frameless procedures.

Entities:  

Keywords:  FPCT = flat-panel CT; biopsy; frameless; robotic; stereotactic radiosurgery

Mesh:

Year:  2014        PMID: 25380111     DOI: 10.3171/2014.9.JNS14107

Source DB:  PubMed          Journal:  J Neurosurg        ISSN: 0022-3085            Impact factor:   5.115


  16 in total

1.  The comparative accuracy of the ROSA stereotactic robot across a wide range of clinical applications and registration techniques.

Authors:  Nicholas J Brandmeir; Sandip Savaliya; Pratik Rohatgi; Michael Sather
Journal:  J Robot Surg       Date:  2017-05-08

Review 2.  Recent technological advances in pediatric brain tumor surgery.

Authors:  Bassel Zebian; Francesco Vergani; José Pedro Lavrador; Soumya Mukherjee; William John Kitchen; Vita Stagno; Christos Chamilos; Benedetta Pettorini; Conor Mallucci
Journal:  CNS Oncol       Date:  2016-12-21

3.  An automatic markerless registration method for neurosurgical robotics based on an optical camera.

Authors:  Fanle Meng; Fangwen Zhai; Bowei Zeng; Hui Ding; Guangzhi Wang
Journal:  Int J Comput Assist Radiol Surg       Date:  2017-11-03       Impact factor: 2.924

4.  Robot-assisted stereoelectroencephalography electrode placement in twenty-three pediatric patients: a high-resolution analysis of individual lead placement time and accuracy at a single institution.

Authors:  David J Bonda; Rachel Pruitt; Liana Theroux; Todd Goldstein; Dimitre G Stefanov; Sanjeev Kothare; Shefali Karkare; Shaun Rodgers
Journal:  Childs Nerv Syst       Date:  2021-03-18       Impact factor: 1.475

5.  Robotics for neuroendovascular intervention: Background and primer.

Authors:  Kazim H Narsinh; Ricardo Paez; Kerstin Mueller; M Travis Caton; Amanda Baker; Randall T Higashida; Van V Halbach; Christopher F Dowd; Matthew R Amans; Steven W Hetts; Alexander M Norbash; Daniel L Cooke
Journal:  Neuroradiol J       Date:  2021-08-16

Review 6.  Minimally Invasive Intracerebral Hemorrhage Evacuation: A review.

Authors:  Mishek J Musa; Austin B Carpenter; Christopher Kellner; Dimitri Sigounas; Isuru Godage; Saikat Sengupta; Chima Oluigbo; Kevin Cleary; Yue Chen
Journal:  Ann Biomed Eng       Date:  2022-02-28       Impact factor: 3.934

7.  Frameless robot-assisted stereotactic biopsy: an effective and minimally invasive technique for pediatric diffuse intrinsic pontine gliomas.

Authors:  Min Wang; Yi Zhang; Wei Shi; Renqing Zhu; Hao Li; Rui Zhao
Journal:  J Neurooncol       Date:  2022-08-23       Impact factor: 4.506

8.  How to avoid pneumocephalus in deep brain stimulation surgery? Analysis of potential risk factors in a series of 100 consecutive patients.

Authors:  Philipp Krauss; Christiaan Hendrik Bas Van Niftrik; Giovanni Muscas; Pierre Scheffler; Markus Florian Oertel; Lennart Henning Stieglitz
Journal:  Acta Neurochir (Wien)       Date:  2020-09-22       Impact factor: 2.216

9.  Contemporary frameless intracranial biopsy techniques: Might variation in safety and efficacy be expected?

Authors:  Iris S C Verploegh; Victor Volovici; Iain K Haitsma; Joost W Schouten; Clemens M Dirven; Johan M Kros; Ruben Dammers
Journal:  Acta Neurochir (Wien)       Date:  2015-08-29       Impact factor: 2.216

10.  Robotic guidance platform for laser interstitial thermal ablation and stereotactic needle biopsies: a single center experience.

Authors:  Franco Rubino; Daniel G Eichberg; Joacir G Cordeiro; Long Di; Karen Eliahu; Ashish H Shah; Evan M Luther; Victor M Lu; Ricardo J Komotar; Michael E Ivan
Journal:  J Robot Surg       Date:  2021-07-13
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.