Literature DB >> 25376699

Safety and efficacy outcomes in patients undergoing pulmonary vein isolation with second-generation cryoballoon†.

Kudret Aytemir1, Kadri Murat Gurses2, Muhammed Ulvi Yalcin1, Duygu Kocyigit1, Muhammet Dural1, Banu Evranos1, Hikmet Yorgun1, Ahmet Hakan Ates3, Mehmet Levent Sahiner1, Ergun Baris Kaya1, Mehmet Ali Oto1.   

Abstract

AIMS: The second-generation cryoballoon (Arctic Front Advance™) (Arc-Adv-CB) has a redesigned injection system which distributes the refrigerant homogenously to the frontal balloon surface. The aim of this study was to compare the efficacy and safety of the Arc-Adv-CB and its predecessor (Arctic Front™) (Arc-CB) in patients who underwent pulmonary vein isolation (PVI) for atrial fibrillation (AF). METHODS AND
RESULTS: Three hundred and six patients (55.35 ± 10.60 years, 47.05% male) were included in the study. A total of 1205 pulmonary veins were attempted for PVI with either Arc-CB or Arc-Adv-CB. The follow-up durations were 30 (23-38) and 10 (8-13) months in Arc-CB and Arc-Adv-CB groups, respectively (P < 0.001). When the blanking period was considered, freedom from AF after a single ablation procedure was 68.53 and 90.83% in patients undergoing PVI with Arc-CB and Arc-Adv-CB, respectively. The most frequent complication was transient phrenic nerve palsy (PNP) which occurred in five(2.54%) and nine(8.26%) of patients undergoing PVI with Arc-CB and Arc-Adv-CB, respectively (P = 0.040). Left atrial (LA) diameter (hazard ratio, HR: 3.552, 95% CI: 2.034-6.201, P < 0.001), smoking history (HR:1.643, 95% CI: 1.011-2.671, P = 0.045), persistent AF (HR:1.725, 95% CI: 1.021-2.915, P = 0.041), duration of AF (HR:1.039, 95% CI: 1.000-1.080, P = 0.047), and early AF recurrence (HR:2.399, 95% CI: 1.443-3.989, P < 0.001) were associated with increased late AF recurrence. On the other hand, intraprocedural vagal reactions (HR: 0.550, 95% CI: 0.331-0.915, P = 0.021) and Arc-Adv-CB use (HR: 0.441, 95% CI: 0.225-0.866, P = 0.017) were associated with lower late AF recurrence. Left atrial diameter (HR: 3.072, 95% CI: 1.646-5.732, P < 0.001), early AF recurrence (HR: 1.906, 95% CI: 1.103-3.291, P = 0.021), and Arc-Adv-CB use (HR: 0.472, 95% CI: 0.239-0.931, P = 0.030) were independent predictors for late AF recurrence.
CONCLUSION: Our study has shown that Arc-Adv-CB use is associated with lower late AF recurrences at the cost of an increased risk for PNP. Published on behalf of the European Society of Cardiology. All rights reserved.
© The Author 2014. For permissions please email: journals.permissions@oup.com.

Entities:  

Keywords:  Ablation; Atrial fibrillation; Cryoballoon; Efficacy; Safety

Mesh:

Year:  2014        PMID: 25376699     DOI: 10.1093/europace/euu273

Source DB:  PubMed          Journal:  Europace        ISSN: 1099-5129            Impact factor:   5.214


  30 in total

1.  Safety and efficacy outcomes of protamine administration for heparin reversal following cryoballoon-based pulmonary vein isolation.

Authors:  Kadri Murat Gurses; Duygu Kocyigit; Muhammed Ulvi Yalcin; Banu Evranos; Hikmet Yorgun; Mehmet Levent Sahiner; Ergun Baris Kaya; Mehmet Ali Oto; Necla Ozer; Kudret Aytemir
Journal:  J Interv Card Electrophysiol       Date:  2015-02-28       Impact factor: 1.900

2.  The novel human gene aprataxin is directly involved in DNA single-strand-break repair.

Authors:  P Mosesso; M Piane; F Palitti; G Pepe; S Penna; L Chessa
Journal:  Cell Mol Life Sci       Date:  2005-02       Impact factor: 9.261

3.  Cryoballoon ablation for pulmonary vein isolation in patients with atrial fibrillation: preliminary results using novel short-tip cryoballoon.

Authors:  Buelent Koektuerk; Hikmet Yorgun; Oezlem Koektuerk; Cem H Turan; Muhammet Necati Murat Aksoy; Ramazan G Turan; Eduard Gorr; Paul M Bansmann; Christian Hoppe; Marc Horlitz
Journal:  J Interv Card Electrophysiol       Date:  2016-05-17       Impact factor: 1.900

4.  First And Second-Generation Cryoballoon Ablation Efficacy Restoring And Maintaining Sinus Rhythm In Patients Electrically Selected And Treated For Long-Standing Persistent Atrial Fibrillation After Acute Complete Electrical Disconnection Of Pulmonary Veins From The Left Atrium Demonstrated.

Authors:  Jesus M Paylos; Luis Azcona; Lourdes Lacal; Marisol Paradela; Carmen Cilleros; Ildefonso Del-Campo; Clara Ferrero Rn Carlos Martínez; Aracelis Morales
Journal:  J Atr Fibrillation       Date:  2016-04-30

5.  Increased rate of observed real-time pulmonary vein isolation with third-generation short-tip cryoballoon.

Authors:  Alexander Pott; Kerstin Petscher; Marvin Messemer; Wolfgang Rottbauer; Tillman Dahme
Journal:  J Interv Card Electrophysiol       Date:  2016-07-23       Impact factor: 1.900

6.  Long-term outcome after second-generation cryoballoon ablation for paroxysmal atrial fibrillation - a 3-years follow-up.

Authors:  Ken Takarada; Ingrid Overeinder; Carlo de Asmundis; Erwin Stroker; Giacomo Mugnai; Valentina de Regibus; Darragh Moran; Hugo Coutino-Moreno; Juan-Pablo Abugattas; Rajin Choudhury; Diego Ruggiero; Gaetano Paparella; Saverio Iacopino; Pedro Brugada; Gian-Battista Chierchia
Journal:  J Interv Card Electrophysiol       Date:  2017-03-10       Impact factor: 1.900

Review 7.  Novel usage of the cryoballoon catheter to achieve large area atrial substrate modification in persistent and long-standing persistent atrial fibrillation.

Authors:  Wilber W Su; Muhanad Alzubaidi; Roger Tseng; Nicholas Jebaily; Yenn-Jiang Lin; Paul J Wang
Journal:  J Interv Card Electrophysiol       Date:  2016-03-03       Impact factor: 1.900

8.  Pulmonary vein isolation in patients with paroxysmal atrial fibrillation : Long-term clinical outcomes with first- and second-generation cryoballoons.

Authors:  B Koektuerk; H Yorgun; A Koch; C H Turan; K Keskin; A Dahmen; C Hoppe; E Gorr; P M Bansmann; R G Turan; M Horlitz; A Yang
Journal:  Herz       Date:  2016-06-22       Impact factor: 1.443

Review 9.  The Hot and the Cold: Radiofrequency Versus Cryoballoon Ablation for Atrial Fibrillation.

Authors:  Richard Ang; Giulia Domenichini; Malcolm C Finlay; Richard J Schilling; Ross J Hunter
Journal:  Curr Cardiol Rep       Date:  2015-09       Impact factor: 2.931

Review 10.  Who Needs Catheter Ablation And Which Approach?

Authors:  Duygu Kocyigit; Ugur Canpolat; Kudret Aytemir
Journal:  J Atr Fibrillation       Date:  2015-12-31