Iterative Reconstruction for Head CT: Effects on Radiation Dose and Image Quality.

Michael D Rivers-Bowerman1, Jai Jai Shiva Shankar2.   

Abstract

BACKGROUND: Iterative reconstruction has been reported to reduce radiation dose in CT, while preserving and even improving image quality. The purpose of this study was to evaluate the effects of sinogram-affirmed iterative reconstruction (SAFIRE) on radiation dose reduction and image quality for noncontrast adult head CT and to compare SAFIRE with conventional filtered back-projection (FBP) reconstruction.
METHODS: Institutional review board approval was obtained for this retrospective analysis of head CT scans reconstructed with SAFIRE and/or FBP for 107 patients. Radiation dose parameters were recorded from scanner-generated CT dose reports. Signal-to-noise and contrast-to-noise ratios (SNR, CNR) were calculated from gray and white matter (GM, WM) attenuation measurements. Image noise, artifacts, GM-WM differentiation, small structure visibility, and sharpness were graded by two readers. Statistical analysis included the independent-samples t test for quantitative data, the related samples Wilcoxon signed-rank test for qualitative data, the coefficient of repeatability for intraobserver variation, and κ statistics for interobserver agreement.
RESULTS: Mean effective dose was significantly reduced with SAFIRE from 2.0 to 1.7 mSv (p<0.0001). SAFIRE also significantly improved GM SNR, WM SNR, and GM-WM CNR (p<0.0001). Significant reductions in image noise and posterior fossa artifact as well as improvements in GM-WM differentiation, small structure visibility, and sharpness were noted with SAFIRE (P<0.005).
CONCLUSIONS: SAFIRE for noncontrast adult head CT reduces patient radiation dose by 15% for the settings employed at our institution, while significantly improving multiple quantitative and qualitative measures of image quality.

Entities:  

Mesh:

Year:  2014        PMID: 25373813     DOI: 10.1017/cjn.2014.11

Source DB:  PubMed          Journal:  Can J Neurol Sci        ISSN: 0317-1671            Impact factor:   2.104


  3 in total

1.  Pediatric head computed tomography with advanced modeled iterative reconstruction: focus on image quality and reduction of radiation dose.

Authors:  Hyun-Hae Cho; So Mi Lee; Sun Kyoung You
Journal:  Pediatr Radiol       Date:  2019-10-19

2.  Deep learning versus iterative image reconstruction algorithm for head CT in trauma.

Authors:  Zlatan Alagic; Jacqueline Diaz Cardenas; Kolbeinn Halldorsson; Vitali Grozman; Stig Wallgren; Chikako Suzuki; Johan Helmenkamp; Seppo K Koskinen
Journal:  Emerg Radiol       Date:  2022-01-05

3.  Dose monitoring in pediatric and young adult head and cervical spine CT studies at two emergency duty departments.

Authors:  Hannele Niiniviita; Timo Kiljunen; Minna Huuskonen; Simo Teperi; Jarmo Kulmala
Journal:  Emerg Radiol       Date:  2017-12-16
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.