Literature DB >> 25367809

Position of Edwards SAPIEN transcatheter valve in the aortic root in relation with the coronary ostia: implications for percutaneous coronary interventions.

Spyridon Katsanos1, Philippe Debonnaire, Frank van der Kley, Philippe J van Rosendael, Emer Joyce, Michiel A de Graaf, Martin J Schalij, Arthur J H A Scholte, Jeroen J Bax, Nina Ajmone Marsan, Victoria Delgado.   

Abstract

OBJECTIVES: To determine the implications of stable coverage of the coronary ostia by the Edwards SAPIEN valve frame in terms of myocardial ischemia and subsequent percutaneous coronary intervention (PCI), following transcatheter aortic valve implantation (TAVI).
BACKGROUND: Edwards SAPIEN frame is frequently deployed relatively higher than recommended and may overlap the coronary ostia.
METHODS: A total of 142 patients (age 81 ± 7 years, male 49%) treated with Edwards SAPIEN valve and with multi-detector row computed tomography at 1 month follow-up were evaluated. The position of the frame in relation to the coronary ostia was assessed. Levels of troponin T were measured 12-24 hr after TAVI. PCI events at follow-up were recorded.
RESULTS: The left coronary ostium was fully covered in three (2.1%) patients and the right coronary ostium in 11 (7.7%). There were no differences in troponin T levels between patients with fully covered ostia versus patients with partly or non-covered ostia (0.24 (0.13-0.50) μg/L versus 0.35 (0.15-0.55) μg/L, respectively; P = 0.377). At 30 ± 15 months follow up, 10 (7%) patients underwent successful PCI. Rate of subsequent PCI was similar between patients with any covered ostium and patients with non-covered ostia [4 (7.8%) vs. 6 (6.5%), P = 0.780, respectively].
CONCLUSIONS: Full overlap of the coronary ostia by Edwards SAPIEN frame is infrequent and in most cases does not limit subsequent PCI.
© 2014 Wiley Periodicals, Inc.

Entities:  

Keywords:  coronary artery disease; electron beam CT/multidetector CT; imaging; transcatheter valve implantation

Mesh:

Substances:

Year:  2014        PMID: 25367809     DOI: 10.1002/ccd.25718

Source DB:  PubMed          Journal:  Catheter Cardiovasc Interv        ISSN: 1522-1946            Impact factor:   2.692


  3 in total

Review 1.  Staged High-Risk Percutaneous Coronary Intervention with Impella Support after On-Pump Transcatheter Aortic Valve Replacement.

Authors:  Sameer Arora; Amol A Bahekar
Journal:  Tex Heart Inst J       Date:  2016-10-01

2.  Clinical and Technical Characteristics of Coronary Angiography and Percutaneous Coronary Interventions Performed before and after Transcatheter Aortic Valve Replacement with a Balloon-Expandable Valve.

Authors:  Alfredo Nunes Ferreira-Neto; Rishi Puri; Lluis Asmarats; Victoria Vilalta; Leonardo Guimaraes; Robert Delarochellière; Jean-Michel Paradis; Siamak Mohammadi; Eric Dumont; Josep Rodés-Cabau
Journal:  J Interv Cardiol       Date:  2019-08-08       Impact factor: 2.279

Review 3.  Percutaneous access to coronary arteries in patients after transcatheter aortic valve implantation procedures - is it a real problem?

Authors:  Piotr Chodór; Krzysztof Wilczek; Roman Przybylski; Jerzy Nożyński; Łukasz Włoch; Zbigniew Kalarus
Journal:  Postepy Kardiol Interwencyjnej       Date:  2019-09-18       Impact factor: 1.426

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.