Literature DB >> 25366975

Applying 'Sequential Windowed Acquisition of All Theoretical Fragment Ion Mass Spectra' (SWATH) for systematic toxicological analysis with liquid chromatography-high-resolution tandem mass spectrometry.

Kathrin Arnhard1, Anna Gottschall, Florian Pitterl, Herbert Oberacher.   

Abstract

Liquid chromatography-tandem mass spectrometry (LC-MS/MS) has become an indispensable analytical technique in clinical and forensic toxicology for detection and identification of potentially toxic or harmful compounds. Particularly, non-target LC-MS/MS assays enable extensive and universal screening requested in systematic toxicological analysis. An integral part of the identification process is the generation of information-rich product ion spectra which can be searched against libraries of reference mass spectra. Usually, 'data-dependent acquisition' (DDA) strategies are applied for automated data acquisition. In this study, the 'data-independent acquisition' (DIA) method 'Sequential Windowed Acquisition of All Theoretical Fragment Ion Mass Spectra' (SWATH) was combined with LC-MS/MS on a quadrupole-quadrupole-time-of-flight (QqTOF) instrument for acquiring informative high-resolution tandem mass spectra. SWATH performs data-independent fragmentation of all precursor ions entering the mass spectrometer in 21m/z isolation windows. The whole m/z range of interest is covered by continuous stepping of the isolation window. This allows numerous repeat analyses of each window during the elution of a single chromatographic peak and results in a complete fragment ion map of the sample. Compounds and samples typically encountered in forensic casework were used to assess performance characteristics of LC-MS/MS with SWATH. Our experiments clearly revealed that SWATH is a sensitive and specific identification technique. SWATH is capable of identifying more compounds at lower concentration levels than DDA does. The dynamic range of SWATH was estimated to be three orders of magnitude. Furthermore, the >600,000 SWATH spectra matched led to only 408 incorrect calls (false positive rate = 0.06 %). Deconvolution of generated ion maps was found to be essential for unravelling the full identification power of LC-MS/MS with SWATH. With the available software, however, only semi-automated deconvolution was enabled, which rendered data interpretation a laborious and time-consuming process.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 25366975     DOI: 10.1007/s00216-014-8262-1

Source DB:  PubMed          Journal:  Anal Bioanal Chem        ISSN: 1618-2642            Impact factor:   4.142


  11 in total

1.  Training in metabolomics research. I. Designing the experiment, collecting and extracting samples and generating metabolomics data.

Authors:  Stephen Barnes; H Paul Benton; Krista Casazza; Sara J Cooper; Xiangqin Cui; Xiuxia Du; Jeffrey Engler; Janusz H Kabarowski; Shuzhao Li; Wimal Pathmasiri; Jeevan K Prasain; Matthew B Renfrow; Hemant K Tiwari
Journal:  J Mass Spectrom       Date:  2016-07       Impact factor: 1.982

2.  Proposed Confidence Scale and ID Score in the Identification of Known-Unknown Compounds Using High Resolution MS Data.

Authors:  Bertrand Rochat
Journal:  J Am Soc Mass Spectrom       Date:  2017-01-23       Impact factor: 3.109

3.  Multi-omic network-based interrogation of rat liver metabolism following gastric bypass surgery featuring SWATH proteomics.

Authors:  Gautham Vivek Sridharan; Matthew D'Alessandro; Shyam Sundhar Bale; Vicky Bhagat; Hugo Gagnon; John M Asara; Korkut Uygun; Martin L Yarmush; Nima Saeidi
Journal:  Technology (Singap World Sci)       Date:  2017-09-26

4.  Prediction and Experimental Validation of a New Salinity-Responsive Cis-Regulatory Element (CRE) in a Tilapia Cell Line.

Authors:  Chanhee Kim; Xiaodan Wang; Dietmar Kültz
Journal:  Life (Basel)       Date:  2022-05-25

Review 5.  Identification of small molecules using accurate mass MS/MS search.

Authors:  Tobias Kind; Hiroshi Tsugawa; Tomas Cajka; Yan Ma; Zijuan Lai; Sajjan S Mehta; Gert Wohlgemuth; Dinesh Kumar Barupal; Megan R Showalter; Masanori Arita; Oliver Fiehn
Journal:  Mass Spectrom Rev       Date:  2017-04-24       Impact factor: 10.946

Review 6.  Computational Metabolomics: A Framework for the Million Metabolome.

Authors:  Karan Uppal; Douglas I Walker; Ken Liu; Shuzhao Li; Young-Mi Go; Dean P Jones
Journal:  Chem Res Toxicol       Date:  2016-10-12       Impact factor: 3.739

Review 7.  Trends in the application of high-resolution mass spectrometry for human biomonitoring: An analytical primer to studying the environmental chemical space of the human exposome.

Authors:  Syam S Andra; Christine Austin; Dhavalkumar Patel; Georgia Dolios; Mahmoud Awawda; Manish Arora
Journal:  Environ Int       Date:  2017-01-04       Impact factor: 9.621

8.  How Safe Is Safe for Marine Toxins Monitoring?

Authors:  Luis M Botana; Amparo Alfonso; Ines Rodríguez; Ana M Botana; Maria Del Carmen Louzao; Mercedes R Vieytes
Journal:  Toxins (Basel)       Date:  2016-07-06       Impact factor: 4.546

9.  Development of a Gill Assay Library for Ecological Proteomics of Threespine Sticklebacks (Gasterosteus aculeatus).

Authors:  Johnathon Li; Bryn Levitan; Silvia Gomez-Jimenez; Dietmar Kültz
Journal:  Mol Cell Proteomics       Date:  2018-08-09       Impact factor: 5.911

10.  Anxiety disturbs the blood plasma metabolome in acute coronary syndrome patients.

Authors:  HongYan Wei; JunYuan Gu; XueYao Jiang; Nan Deng; Jing Wu; LianHong Zou; YiMin Zhu; BoYu Tan
Journal:  Sci Rep       Date:  2021-06-18       Impact factor: 4.379

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.