Matthias Hammon1, Peter Dankerl1, Heinz Leonhard Voit-Höhne2, Martin Sandmair1, Ferdinand Josef Kammerer1, Michael Uder1, Rolf Janka1.
Abstract
BACKGROUND: To assess the value of a score-based system which allows standardized evaluation of pulmonary edema on bedside chest radiographs (CXRs) under routine clinical conditions.Entities:
Keywords: Bedside chest radiograph; Extravascular lung water (EVLW); Pulmonary edema; Scoring system; Web-based application
Mesh:
Year: 2014 PMID: 25364301 PMCID: PMC4216356 DOI: 10.1186/1471-2253-14-94
Source DB: PubMed Journal: BMC Anesthesiol ISSN: 1471-2253 Impact factor: 2.217
Figure 1Bedside chest radiographs showing different indications of pulmonary edema. Enlarged/blurred hilar vessels (a), Kerley lines (lower arrow) and peribronchial/perivascular cuffs (upper arrow) (b), micronoduli (c) widening of interlobular fissure (d), extensive perihilar haze (e) and diffuse increase in density (f).
Radiologic scoring of pulmonary edema on bedside chest radiographs
| Variables | Score | |||
|---|---|---|---|---|
| Mild | Moderate | Severe | ||
| Hilar vessels | Enlarged | 1 | 2 | 3 |
| Increased in density | 2 | 4 | 6 | |
| Blurred | 3 | 6 | 9 | |
| Kerley B lines | 4 | - | 8 | |
| Micronoduli | 4 | - | 8 | |
| Widening of interlobular fissure | 4 | 8 | 12 | |
| Peribronchial and perivascular cuffs | 4 | 8 | 12 | |
| Extensive perihilar haze | 5 | 10 | 15 | |
| Diffuse increase in density | 5 | 10 | 15 | |
The score assigned to each variable depends on the severity of involvement (missing = 0 points, mild, moderate and severe). During the score-based approach a total score > 15 was rated as pulmonary edema, whereas a score ≤ 15 was rated as no pulmonary edema. The variables and scores were previously validated [1, 13, 28, 29].
Figure 2Example bedside chest radiograph with indications of pulmonary edema. a) Pulse contour cardiac output (PiCCO) measurements showed an extravascular lung water (EVLW)-value of 21 mL/kg, indicating pulmonary edema. b) Results of the score-based approach (total score = 24, indicates pulmonary edema).
Figure 3Example bedside chest radiograph with no indications of pulmonary edema. a) Pulse contour cardiac output (PiCCO) measurements showed an extravascular lung water (EVLW)-value of 7 mL/kg, indicating no pulmonary edema. b) Result of the score-based approach (total score = 4, indicates no pulmonary edema).
Performance of the readers with the score-based and with the standard approach
| Score-based approach | Standard approach | ||||
|---|---|---|---|---|---|
| Pulmonary edema | No pulmonary edema | Pulmonary edema | No pulmonary edema | Net reclassification index | |
| Reader 1 (3) | 8 | 10 | 5 | 10 | 0.3 (0.04; 95% CI: 0.02 – 0.58) |
| Reader 2 (3) | 6 | 10 | 5 | 10 | 0.1 (0.56; 95% CI: -0.23 – 0.43) |
| Reader 3 (3) | 8 | 10 | 6 | 6 | 0.6 (0.003; 95% CI: 0.21 – 0.99) |
| Reader 4 (4) | 8 | 10 | 5 | 9 | 0.4 (0.02; 95% CI: 0.06 – 0.74) |
| Reader 5 (4) | 7 | 10 | 5 | 9 | 0.3 (0.06; 95% CI: -0.01 – 0.61) |
| Reader 6 (6) | 9 | 10 | 8 | 10 | 0.1 (0.29; 95% CI: -0.09 – 0.29) |
| Reader 7 (7) | 8 | 10 | 6 | 9 | 0.3 (0.06; 95% CI: -0.01 – 0.61) |
| All readers | 54/70 | 70/70 | 40/70 | 63/70 | 0.3 (0.000002; CI: 0.18 – 0.42) |
| Mean sensitivity [%] | 77.14 (95% CI: 65.28 – 85.99) | 57.14 (95% CI: 44.78 – 68.72) | |||
| Mean specificity [%] | 100 (95% CI: 93.52 -100) | 90.00 (95% CI: 79.90 – 95.55) | |||
| Positive predictive value [%] | 100 (95% CI: 91.73 – 100) | 85.11 (95% CI: 71.08 – 93.31) | |||
| Negative predictive value [%] | 81.40 (95% CI: 71.25 – 88.67) | 67.74 (95% CI: 57.15 – 76.85) | |||
| Free-marginal multirater kappa value | 0.68 | 0.34 | |||
| Percentage of overall agreement [%] | 67 | 84 | |||
| Duration [seconds] | 23 ± 12 | 7 ± 3 | |||
The first seven rows show the numbers of correct diagnoses (10 bedside CXRs total) during the assessment of ten bedside chest radiographs with and without pulmonary edema each, practicing the score-based and the standard approach (extravascular lung water (EVLW) measurements determined by a pulse contour cardiac output (PiCCO) system served as reference standard). Work experience of the participating radiologists in years is shown in brackets. The net reclassification index demonstrates the improvement in prediction performance gained by the score-based approach (p-values and confidence intervals are shown in brackets). Sensitivities, specificities, positive and negative predictive values, free-marginal multirater kappa values, the percentage of overall agreement and duration are shown for both approaches. The confidence level is 95%. CI = Confidence interval.