Acetabular re-revision with impaction bone grafting and a cemented polyethylene cup; a biological option for successive reconstructions.

B Willem Schreurs1, Martijn A J Te Stroet, Wim H C Rijnen, Jean W M Gardeniers.   

Abstract

INTRODUCTION: For the revision of failed acetabular components impaction bone grafting (IBG) with a cemented cup is a well known technique. Claims have been made that this is a biological reconstruction technique, restoring the bone stock loss and thereby facilitating future revisions. However, there are no scientific data proving this claim. PATIENTS AND METHODS: In this study, we present the clinical and radiographic outcome of 11 consecutive acetabular re-revisions in 10 patients with again IBG and a cemented polyethylene cup observed in a previously reported cohort of 62 acetabular IBG revisions. All data were prospectively collected. Kaplan-Meier survivorship analysis was performed.
RESULTS: The mean follow-up after re-revision was 10 years (5-15) and 28 years (26-30) after the primary revision. No patients were lost to follow-up. The mean HHS improved from 37 (12-49) points to 71 (40-95) points at final follow-up. Survival with further cup revision for any reason as endpoint was 91% (95% confidence interval (CI) 51 to 99) at 10 years. When excluding one early cup re-revision for malpositioning 3 weeks postoperative, survivorship with further cup revision for aseptic loosening as endpoint was 100% (95% CI 37-100) at 10 years. Survival with further cup re-operation for any reason as endpoint was 82% (95% one-sided CI 45-95). In all surviving re-revisions trabecular incorporation was observed without radiolucent lines.
CONCLUSION: This study shows that, due to restoring the bone stock, even successive acetabular reconstructions using IBG and a cemented cup are possible with satisfying 10 years survivorship.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 25362880     DOI: 10.5301/hipint.5000193

Source DB:  PubMed          Journal:  Hip Int        ISSN: 1120-7000            Impact factor:   2.135


  2 in total

1.  Impaction Bone Grafting Combined with Titanium Mesh for Acetabular Bone Defects Reconstruction in Total Hip Arthroplasty Revision: A Retrospective and Mini-Review Study.

Authors:  Xiang Li; Bai-Qi Pan; Xiao-Yu Wu; Ming Fu; Wei-Ming Liao; Chu-Heng Wu; Pu-Yi Sheng
Journal:  Orthop Surg       Date:  2022-04-20       Impact factor: 2.279

2.  Functional and radiological outcomes after treatment with custom-made acetabular components in patients with Paprosky type 3 acetabular defects: short-term results.

Authors:  Michael S Gruber; Michael Jesenko; Julia Burghuber; Josef Hochreiter; Peter Ritschl; Reinhold Ortmaier
Journal:  BMC Musculoskelet Disord       Date:  2020-12-10       Impact factor: 2.362

  2 in total