Literature DB >> 25361560

Rupture of giant vertebrobasilar aneurysm following flow diversion: mechanical stretch as a potential mechanism for early aneurysm rupture.

Benjamin Fox1, William Edward Humphries2, Vinodh T Doss3, Daniel Hoit4, Lucas Elijovich5, Adam S Arthur6.   

Abstract

A patient with a giant symptomatic vertebrobasilar aneurysm was treated by endoscopic third ventriculostomy for obstructive hydrocephalus followed by treatment of the aneurysm by flow diversion using a Pipeline Embolization Device. After an uneventful procedure and initial periprocedural period, the patient experienced an unexpected fatal subarachnoid hemorrhage 1 week later. Autopsy demonstrated extensive subarachnoid hemorrhage and aneurysm rupture (linear whole wall rupture). The patent Pipeline Embolization Device was in its intended location, as was the persistent coil occlusion of the distal left vertebral artery. The aneurysm appeared to rupture in a linear manner and contained a thick large expansile clot that seemed to disrupt or rupture the thin aneurysm wall directly opposite the basilar artery/Pipeline Embolization Device. We feel the pattern of aneurysm rupture in our patient supports the idea that the combination of flow diversion and the resulting growing intra-aneurysmal thrombus can create a mechanical force with the potential to cause aneurysm rupture. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

Entities:  

Keywords:  Aneurysm; Complication; Flow Diverter; Hemorrhage; Hydrocephalus

Mesh:

Year:  2014        PMID: 25361560     DOI: 10.1136/neurintsurg-2014-011325.rep

Source DB:  PubMed          Journal:  J Neurointerv Surg        ISSN: 1759-8478            Impact factor:   5.836


  9 in total

1.  The first North American use of the Pipeline Flex flow diverter.

Authors:  Edward A M Duckworth; Christopher Nickele; Daniel Hoit; Andrey Belayev; Christopher J Moran; Adam S Arthur
Journal:  BMJ Case Rep       Date:  2015-01-30

Review 2.  Complications of endovascular treatment for intracranial aneurysms: Management and prevention.

Authors:  Yon Kwon Ihn; Shang Hun Shin; Seung Kug Baik; In Sup Choi
Journal:  Interv Neuroradiol       Date:  2018-02-21       Impact factor: 1.610

3.  FRED Flow Diverter: A Study on Safety and Efficacy in a Consecutive Group of 50 Patients.

Authors:  H Luecking; T Engelhorn; S Lang; P Goelitz; S Kloska; K Roessler; A Doerfler
Journal:  AJNR Am J Neuroradiol       Date:  2017-01-19       Impact factor: 3.825

4.  The pressure reduction coefficient: A new parameter to assess aneurysmal blood stasis induced by flow diverters/disruptors.

Authors:  Gregory Gascou; Riccardo Ferrara; Dominique Ambard; Mathieu Sanchez; Kyriakos Lobotesis; Franck Jourdan; Vincent Costalat
Journal:  Interv Neuroradiol       Date:  2016-12-05       Impact factor: 1.610

5.  Delayed rupture of intracranial aneurysms after placement of intra-luminal flow diverter.

Authors:  Kun Hou; Guichen Li; Xianli Lv; Baofeng Xu; Kan Xu; Jinlu Yu
Journal:  Neuroradiol J       Date:  2020-08-27

6.  Delayed aneurysm rupture due to residual blood flow at the inflow zone of the intracranial paraclinoid internal carotid aneurysm treated with the Pipeline embolization device: Histopathological investigation.

Authors:  Hiroyuki Ikeda; Akira Ishii; Takayuki Kikuchi; Mitsushige Ando; Hideo Chihara; Daisuke Arai; Etsuko Hattori; Susumu Miyamoto
Journal:  Interv Neuroradiol       Date:  2015-10-23       Impact factor: 1.610

7.  Hemodynamic Analysis of Postoperative Rupture of Unruptured Intracranial Aneurysms after Placement of Flow-Diverting Stents: A Matched Case-Control Study.

Authors:  W Li; Z Tian; W Zhu; Y S Zhang; K Wang; Y Zhang; Y Wang; X Yang; J Liu
Journal:  AJNR Am J Neuroradiol       Date:  2019-10-17       Impact factor: 3.825

Review 8.  Mechanical stretch: physiological and pathological implications for human vascular endothelial cells.

Authors:  Nurul F Jufri; Abidali Mohamedali; Alberto Avolio; Mark S Baker
Journal:  Vasc Cell       Date:  2015-09-18

9.  Pipeline Embolization Device With Adjunctive Coils for the Treatment of Unruptured Large or Giant Vertebrobasilar Aneurysms: A Single-Center Experience.

Authors:  Yangyang Zhou; Xinzhi Wu; Zhongbin Tian; Xinjian Yang; Shiqing Mu
Journal:  Front Neurol       Date:  2020-10-30       Impact factor: 4.003

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.