Literature DB >> 25361016

Saphenous Vein Graft Wrapping by Nitinol Mesh: A Word of Caution.

Giuseppe Rescigno1, Carlo Aratari1, Sacha Marco Matteucci1, Rosario Parisi2, Giulia Gironi1, Niccolò Schicchi3, Alessandro D'Alfonso1, Valentina Cola4, Lucia Torracca1.   

Abstract

BACKGROUND: Saphenous vein conduits are still used in a large proportion of coronary artery bypass graft (CABG) operations. A recently commercialized nitinol mesh seems to improve venous graft patency. The aim of this study was to control nitinol mesh vein graft patency in a series of isolated CABG patients by computed tomographic (CT) scan.
METHODS: In 25 patients (mean age: 61.0 ± 9.65 years), operated for isolated CABG, the eSVS nitinol mesh (Kips Bay Medical Inc., Minneapolis, Minnesota, United States) was used to wrap one vein graft in each patient. Nitinol mesh vein graft was used to revascularize the right coronary (4 patients; 16%), the posterior descending (18 patients; 72%), and the obtuse marginal (3 patients; 12%) arteries. CT scans were performed at 1, 6, and 12 months postoperatively.
RESULTS: The procedure was uneventful in all patients. CT controls showed an overall patency rate of 86.9, 42.7, and 34.1% at 1, 6, and 12 months, respectively. The 4 mm mesh had a significantly higher patency rate at 12 months (83.33%) than the 3.5 mm one which showed quite unsatisfactory results (20%) (p = 0.02). Patients with graft occlusion underwent stress testing which was mildly positive in two cases. One of them underwent a percutaneous revascularization.
CONCLUSION: Despite promising early results, use of nitinol mesh for saphenous veins was disappointing in our experience. Further refinements are probably needed. Georg Thieme Verlag KG Stuttgart · New York.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 25361016     DOI: 10.1055/s-0034-1393705

Source DB:  PubMed          Journal:  Thorac Cardiovasc Surg        ISSN: 0171-6425            Impact factor:   1.827


  4 in total

Review 1.  Biomaterial-Based Approaches to Address Vein Graft and Hemodialysis Access Failures.

Authors:  Timothy C Boire; Daniel A Balikov; Yunki Lee; Christy M Guth; Joyce Cheung-Flynn; Hak-Joon Sung
Journal:  Macromol Rapid Commun       Date:  2016-09-27       Impact factor: 5.734

Review 2.  Saphenous vein grafts in contemporary coronary artery bypass graft surgery.

Authors:  Etem Caliskan; Domingos Ramos de Souza; Andreas Böning; Oliver J Liakopoulos; Yeong-Hoon Choi; John Pepper; C Michael Gibson; Louis P Perrault; Randall K Wolf; Ki-Bong Kim; Maximilian Y Emmert
Journal:  Nat Rev Cardiol       Date:  2019-08-27       Impact factor: 32.419

Review 3.  Twenty-Five Years of No-Touch Saphenous Vein Harvesting for Coronary Artery Bypass Grafting: Structural Observations and Impact on Graft Performance.

Authors:  Ninos Samano; Domingos Souza; Bruno Botelho Pinheiro; Tomislav Kopjar; Michael Dashwood
Journal:  Braz J Cardiovasc Surg       Date:  2020-02-01

4.  Effects of the different-sized external stents on vein graft intimal hyperplasia and inflammation.

Authors:  Qi Yang; Dong Lei; Shixing Huang; Yi Yang; Yang Yang; Xiaofeng Ye; Zhengwei You; Qiang Zhao
Journal:  Ann Transl Med       Date:  2020-02
  4 in total