Literature DB >> 25360701

Corneal thickness differences between sexes after oxybuprocaine eye drops.

Pablo Fernandez-Garcia1, Alejandro Cerviño, Laura Quiles-Guiñau, Cesar Albarran-Diego, Santiago Garcia-Lazaro, Juan A Sanchis-Gimeno.   

Abstract

PURPOSE: We aimed to analyze the corneal thickness (CT) values of female and male subjects before and after instillation of oxybuprocaine 0.4% anesthetic eye drops.
METHODS: The CT of 30 female subjects and 28 male subjects was measured using scanning-slit corneal topography (Orbscan Topography System II, Orbscan, Inc, Salt Lake City, UT). Measurements were carried out before and 3 minutes after the instillation of oxybuprocaine 0.4% eye drops.
RESULTS: The difference between the baseline values and those obtained after anesthesia ranged as follows: male subjects: central, -26 to +24 μm; superior, -24 to +23 μm; inferior, -19 to +20 μm; nasal, -25 to +30 μm; and temporal, -21 to +20 μm; female subjects: central, -16 to +24 μm; superior, -19 to +32 μm; inferior, -14 to +34 μm; nasal, -19 to +33 μm; and temporal, -36 to +16 μm. No significant differences were found in any corneal location in male subjects. The differences were significant at inferior (p = 0.001) and nasal (p = 0.011) corneal sites in female subjects.
CONCLUSIONS: Oxybuprocaine anesthetic eye drops induce significant CT increases in female subjects but not in male subjects.

Entities:  

Mesh:

Substances:

Year:  2015        PMID: 25360701     DOI: 10.1097/OPX.0000000000000449

Source DB:  PubMed          Journal:  Optom Vis Sci        ISSN: 1040-5488            Impact factor:   1.973


  4 in total

1.  Letter to the editor. "Comparison of specular microscopy and ultrasound pachymetry before and after cataract surgery".

Authors:  Alberto López-Miguel; María Sanchidrián; Itziar Fernández; Alfredo Holgueras; Miguel J Maldonado
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2017-02-11       Impact factor: 3.117

Review 2.  Corneal topography in keratoconus: state of the art.

Authors:  F Cavas-Martínez; E De la Cruz Sánchez; J Nieto Martínez; F J Fernández Cañavate; D G Fernández-Pacheco
Journal:  Eye Vis (Lond)       Date:  2016-02-22

3.  Accuracy of Cirrus HD-OCT and Topcon SP-3000P for measuring central corneal thickness.

Authors:  Jorge A Calvo-Sanz; Javier Ruiz-Alcocer; Miguel A Sánchez-Tena
Journal:  J Optom       Date:  2017-02-21

4.  Corneal Thickness Response after Anesthetic Eye Drops: Our Own Results and Meta-Analysis.

Authors:  Marcelino Perez-Bermejo; Alejandro Cervino; Ana M Calvo-Maroto; Monica Moscardo; Mayte Murillo-Llorente; Juan A Sanchis-Gimeno
Journal:  Biomed Res Int       Date:  2018-03-05       Impact factor: 3.411

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.