Literature DB >> 25359719

Assessment of cardiac output with transpulmonary thermodilution during exercise in humans.

José A L Calbet1, Robert Boushel2.   

Abstract

The accuracy and reproducibility of transpulmonary thermodilution (TPTd) to assess cardiac output (Q̇) in exercising men was determined using indocyanine green (ICG) dilution as a reference method. TPTd has been utilized for the assessment of Q̇ and preload indexes of global end-diastolic volume and intrathoracic blood volume, as well as extravascular lung water (EVLW) in resting humans. It remains unknown if this technique is also accurate and reproducible during exercise. Sixteen healthy men underwent catheterization of the right femoral vein (for iced saline injection), an antecubital vein (ICG injection), and femoral artery (thermistor) to determine their Q̇ by TPTd and ICG concentration during incremental one- and two-legged pedaling on a cycle ergometer and combined arm cranking with leg pedaling to exhaustion. There was a close relationship between TPTd-Q̇ and ICG-Q̇ (r = 0.95, n = 151, standard error of the estimate: 1.452 l/min, P < 0.001; mean difference of 0.06 l/min; limits of agreement -2.98 to 2.86 l/min), and TPTd-Q̇ and ICG-Q̇ increased linearly with oxygen uptake with similar intercepts and slopes. Both methods had mean coefficients of variation close to 5% for Q̇, global end-diastolic volume, and intrathoracic blood volume. The mean coefficient of variation of EVLW, assessed with both indicators (ICG and thermal) was 17% and was sensitive enough to detect a reduction in EVLW of 107 ml when changing from resting supine to upright exercise. In summary, TPTd with bolus injection into the femoral vein is an accurate and reproducible method to assess Q̇ during exercise in humans.
Copyright © 2015 the American Physiological Society.

Entities:  

Keywords:  cardiac output; exercise; human; indocyanine; thermodilution

Mesh:

Year:  2014        PMID: 25359719     DOI: 10.1152/japplphysiol.00686.2014

Source DB:  PubMed          Journal:  J Appl Physiol (1985)        ISSN: 0161-7567


  8 in total

1.  Consistency of cardiac function index and global ejection fraction with global end-diastolic volume in patients with femoral central venous access for transpulmonary thermodilution: a prospective observational study.

Authors:  Analena Beitz; Helena Berbara; Sebastian Mair; Benedikt Henschel; Tobias Lahmer; Sebastian Rasch; Roland Schmid; Wolfgang Huber
Journal:  J Clin Monit Comput       Date:  2016-04-21       Impact factor: 2.502

2.  Femoral indicator injection for transpulmonary thermodilution using the EV1000/VolumeView(®): do the same criteria apply as for the PiCCO(®)?

Authors:  Wolfgang Huber; Veit Phillip; Josef Höllthaler; Caroline Schultheiss; Bernd Saugel; Roland M Schmid
Journal:  J Zhejiang Univ Sci B       Date:  2016-07       Impact factor: 3.066

3.  Unexplained exertional intolerance associated with impaired systemic oxygen extraction.

Authors:  Kathryn H Melamed; Mário Santos; Rudolf K F Oliveira; Mariana Faria Urbina; Donna Felsenstein; Alexander R Opotowsky; Aaron B Waxman; David M Systrom
Journal:  Eur J Appl Physiol       Date:  2019-09-06       Impact factor: 3.078

4.  Limitations to oxygen transport and utilization during sprint exercise in humans: evidence for a functional reserve in muscle O2 diffusing capacity.

Authors:  José A L Calbet; José Losa-Reyna; Rafael Torres-Peralta; Peter Rasmussen; Jesús Gustavo Ponce-González; A William Sheel; Jaime de la Calle-Herrero; Amelia Guadalupe-Grau; David Morales-Alamo; Teresa Fuentes; Lorena Rodríguez-García; Christoph Siebenmann; Robert Boushel; Carsten Lundby
Journal:  J Physiol       Date:  2015-09-10       Impact factor: 5.182

Review 5.  Leveraging Engineering of Indocyanine Green-Encapsulated Polymeric Nanocomposites for Biomedical Applications.

Authors:  Ya-Hui Han; Ranjith Kumar Kankala; Shi-Bin Wang; Ai-Zheng Chen
Journal:  Nanomaterials (Basel)       Date:  2018-05-24       Impact factor: 5.076

6.  Arterial to end-tidal Pco2 difference during exercise in normoxia and severe acute hypoxia: importance of blood temperature correction.

Authors:  José Losa-Reyna; Rafael Torres-Peralta; Juan José González Henriquez; José A L Calbet
Journal:  Physiol Rep       Date:  2015-10

7.  Comparison of global end-diastolic volume index derived from jugular and femoral indicator injection: a prospective observational study in patients equipped with both a PiCCO-2 and an EV-1000-device.

Authors:  Alexander Herner; Markus Heilmaier; Ulrich Mayr; Roland M Schmid; Wolfgang Huber
Journal:  Sci Rep       Date:  2020-11-27       Impact factor: 4.379

8.  Constant-rate intravenous infusion of indocyanine green leading to high fluorescence intensity in infrared thoracoscopic segmentectomy.

Authors:  Noriyuki Misaki; Kiichi Tatakawa; Sung Soo Chang; Tetsuhiko Go; Hiroyasu Yokomise
Journal:  JTCVS Tech       Date:  2020-05-11
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.