Literature DB >> 25355014

Capillary scale admittance detection.

Min Zhang1, Brian N Stamos, Natchanon Amornthammarong, Purnendu K Dasgupta.   

Abstract

Techniques that have been variously termed oscillometric detection or (capacitively coupled) contactless conductivity detection (C(4)D) are known actually to respond to the admittance. It is not often appreciated that the frequency range (f) over which such systems respond (quasi)linearly with the cell conductance decreases acutely with increasing cell resistance. Guidance on optimum operating conditions for high cell resistance, such as for very small capillaries/channels and/or solutions of low specific conductance (σ), is scant. It is specially necessary in this case to take the capacitance of the solution into account. At high frequencies and low σ values, much of the current passes through the solution behaving as a capacitor and the capacitance is not very dependent on the exact solution specific conductance, resulting in poor, zero, or even negative response. We investigated, both theoretically and experimentally, capillaries with inner radii of 5-160 μm and σ ≈ 1-1400 μS/cm, resulting in cell resistances of 51 GΩ to 176 kΩ. A 400-element discrete model was used to simulate the behavior. As model inputs, both the wall capacitance and the stray capacitance were measured. The solution and leakage capacitances were estimated from extant models. The model output was compared to the measured response of the detection system over broad ranges of f and σ. Other parameters studied include capillary material and wall thickness, electrode spacing and length, Faraday shield thickness, excitation wave forms, and amplitude. The simulations show good qualitative agreement with experimental results and correctly predict the negative response behavior observed under certain conditions. We provide optimum frequencies for different operating conditions.

Year:  2014        PMID: 25355014     DOI: 10.1021/ac503245a

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  2 in total

1.  Rapid quantitation of multiple ions released from HeLa cells during emodin induced apoptosis by low-cost capillary electrophoresis with capacitively coupled contactless conductivity detection.

Authors:  Jing Zhang; Xuan Wei; Yuanhang Wang; Bo Ren; Litao Zhao; Zhaoyan Wang; Qiaosheng Pu
Journal:  RSC Adv       Date:  2018-05-18       Impact factor: 3.361

2.  [Multimaterial 3D-printed contactless conductivity/laser-induced fluorescence dual-detection cell for capillary electrophoresis].

Authors:  Piwang Zhang; Liye Yang; Qiang Liu; Shangui Lu; Ying Liang; Min Zhang
Journal:  Se Pu       Date:  2021-08