Isocapnic hyperpnea with a portable device in Cystic Fibrosis: an agreement study between two different set-up modalities.

Simone Gambazza1, Clara Ceruti2, Anna Brivio2, Giancarlo Piaggi3, Solon Karapanagiotis2, Carla Colombo2.   

Abstract

To evaluate the bias and precision of the respiratory muscle training device formulas to predict respiratory minute volume (RMV) and volume of the reservoir bag (BV) on a cohort of subjects with Cystic Fibrosis (CF). CF patients with available pulmonary function tests and maximal voluntary manoeuvres were included in the study. Vital capacity and maximal voluntary ventilation were extracted from subjects' records and then inserted to the manufacturer's formulas to obtain RMV and BV (measured setting). RMV and BV were compared according to standard and measured formulas in males and females. Sample was described and then processed using Bland-Altman analysis. Bland-Altman analysis for RMV revealed a bias and precision of 8.8 ± 29 L/min in males and 28.8 ± 16 L/min in females; 0.4 ± 0.5 L in males and 0.7 ± 0.4 L in females for BV. Concordance correlation coefficients for RMV were -0.03 in males and 0.02 in females; 0.22 in males and 0.03 in females for BV, reinforcing an unsatisfactory concordance between measured and manufacturer setting. This study shows considerable discrepancies between the two methods, making the degree of agreement not clinically acceptable. This might cause inappropriate setting and disservice to patients with CF.

Entities:  

Keywords:  Cystic Fibrosis; Respiratory muscle training; Spirometry

Mesh:

Year:  2014        PMID: 25348833     DOI: 10.1007/s10877-014-9633-z

Source DB:  PubMed          Journal:  J Clin Monit Comput        ISSN: 1387-1307            Impact factor:   2.502


  8 in total

Review 1.  Measuring agreement in method comparison studies.

Authors:  J M Bland; D G Altman
Journal:  Stat Methods Med Res       Date:  1999-06       Impact factor: 3.021

2.  A note on concordance correlation coefficient.

Authors:  J J Liao; J W Lewis
Journal:  PDA J Pharm Sci Technol       Date:  2000 Jan-Feb

Review 3.  Effect of respiratory muscle training on exercise performance in healthy individuals: a systematic review and meta-analysis.

Authors:  Sabine K Illi; Ulrike Held; Irène Frank; Christina M Spengler
Journal:  Sports Med       Date:  2012-08-01       Impact factor: 11.136

Review 4.  Coming together: the ATS/ERS consensus on clinical pulmonary function testing.

Authors:  V Brusasco; R Crapo; G Viegi
Journal:  Eur Respir J       Date:  2005-07       Impact factor: 16.671

5.  Isocapnic hyperpnea training improves performance in competitive male runners.

Authors:  John J Leddy; Atcharaporn Limprasertkul; Snehal Patel; Frank Modlich; Cathy Buyea; David R Pendergast; Claes E G Lundgren
Journal:  Eur J Appl Physiol       Date:  2007-01-23       Impact factor: 3.078

6.  A concordance correlation coefficient to evaluate reproducibility.

Authors:  L I Lin
Journal:  Biometrics       Date:  1989-03       Impact factor: 2.571

7.  Ventilatory muscle endurance training in normal subjects and patients with cystic fibrosis.

Authors:  T G Keens; I R Krastins; E M Wannamaker; H Levison; D N Crozier; A C Bryan
Journal:  Am Rev Respir Dis       Date:  1977-11

8.  Respiratory training with a specific device in cystic fibrosis: a prospective study.

Authors:  R Sartori; E Barbi; F Poli; L Ronfani; F Marchetti; A Amaddeo; A Ventura
Journal:  J Cyst Fibros       Date:  2008-02-01       Impact factor: 5.482

  8 in total
  1 in total

Review 1.  Journal of Clinical Monitoring and Computing 2015 end of year summary: respiration.

Authors:  D S Karbing; S E Rees; M B Jaffe
Journal:  J Clin Monit Comput       Date:  2015-12-30       Impact factor: 2.502

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.