Literature DB >> 25348476

IDEAL 3D spoiled gradient echo of the articular cartilage of the knee on 3.0 T MRI: a comparison with conventional 3.0 T fast spin-echo T2 fat saturation image.

Chul Hee Han1, Hee Jin Park2, So Yeon Lee1, Eun Chul Chung1, Seon Hyeong Choi1, Ji Sup Yun3, Myung Ho Rho1.   

Abstract

BACKGROUND: Many two-dimensional (2D) morphologic cartilage imaging sequences have disadvantages such as long acquisition time, inadequate spatial resolution, suboptimal tissue contrast, and image degradation secondary to artifacts. IDEAL imaging can overcome these disadvantages.
PURPOSE: To compare sound-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and quality of two different methods of imaging that include IDEAL 3D SPGR and 3.0-T FSE T2 fat saturation (FS) imaging and to evaluate the utility of IDEAL 3D SPGR for knee joint imaging.
MATERIAL AND METHODS: SNR and CNR of the patellar and femoral cartilages were measured and calculated. Two radiologists performed subjective scoring of all images for three measures: general image quality, FS, and cartilage evaluation. SNR and CNR values were compared by paired Student's t-tests.
RESULTS: Mean SNRs of patellar and femoral cartilages were 90% and 66% higher, respectively, for IDEAL 3D SPGR. CNRs of patellar cartilages and joint fluids were 2.4 times higher for FSE T2 FS, and CNR between the femoral cartilage and joint fluid was 2.2 times higher for FSE T2 FS. General image quality and FS were superior using FSE T2 FS compared to those of IDEAL 3D SPGR imaging according to both readers, while cartilage evaluation was superior using IDEAL 3D SPGR. Additionally, cartilage injuries were more prominent in IDEAL 3D SPGR than in FSE T2FS according to both readers.
CONCLUSION: IDEAL 3D SPGR images show excellent visualization of patellar and femoral cartilages in 3.0 T and can compensate for the weaknesses of FSE T2 FS in the evaluation of cartilage injuries. © The Foundation Acta Radiologica 2014.

Entities:  

Keywords:  Magnetic resonance imaging (MRI); cartilage; iterative decomposition of water and fat with echo asymmetry and least-squares estimation; knee

Mesh:

Year:  2014        PMID: 25348476     DOI: 10.1177/0284185114556097

Source DB:  PubMed          Journal:  Acta Radiol        ISSN: 0284-1851            Impact factor:   1.990


  2 in total

1.  Initial experience with synthetic MRI of the knee at 3T: comparison with conventional T1 weighted imaging and T2 mapping.

Authors:  Sunghoon Park; Kyu-Sung Kwack; Young Ju Lee; Sung-Min Gho; Hyun Young Lee
Journal:  Br J Radiol       Date:  2017-11-16       Impact factor: 3.039

2.  Usefulness of the fast spin-echo three-point Dixon (mDixon) image of the knee joint on 3.0-T MRI: comparison with conventional fast spin-echo T2 weighted image.

Authors:  Hee J Park; So Y Lee; Myung H Rho; Eun C Chung; Jin H Ahn; Jai H Park; In S Lee
Journal:  Br J Radiol       Date:  2016-03-23       Impact factor: 3.039

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.