Literature DB >> 25347875

Analysis of laser speckle contrast images variability using a novel empirical mode decomposition: comparison of results with laser Doppler flowmetry signals variability.

Anne Humeau-Heurtier, Pierre Abraham, Guillaume Mahe.   

Abstract

Laser Doppler flowmetry (LDF) and laser speckle contrast imaging (LSCI) have emerged as noninvasive optical modalities to monitor microvascular blood flow. Many studies proposed to extract physiological information from LDF by analyzing signals variability. By opposition, such analyses for LSCI data have not been conducted yet. We propose to analyze LSCI variability using a novel data-driven method: the complete ensemble empirical mode decomposition with adaptive noise (CEEMDAN). CEEMDAN is suitable for nonlinear and nonstationary data and leads to intrinsic mode functions (IMFs). It is based on the ensemble empirical mode decomposition (EEMD) which relies on empirical mode decomposition (EMD). In our work the average frequencies of LSCI IMFs given by CEEMDAN are compared with the ones given by EMD and EEMD. Moreover, LDF signals acquired simultaneously to LSCI data are also processed with CEEMDAN, EMD and EEMD. We show that the average frequencies of IMFs given by CEEMDAN depend on the signal-to-noise ratio (SNR) used in the computation but, for a given SNR, the average frequencies found for LSCI are close to the ones obtained for LDF. By opposition, EEMD leads to IMFs with frequencies that do not vary much when the SNR level is higher than a threshold. The new CEEMDAN algorithm has the advantage of achieving a complete decomposition with no error in the reconstruction but our study suggests that further work is needed to gain knowledge in the adjustment of the added noise level. CEEMDAN, EMD and EEMD are data-driven methods that can provide a better knowledge of LSCI.

Entities:  

Mesh:

Year:  2014        PMID: 25347875     DOI: 10.1109/TMI.2014.2364079

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  3 in total

1.  A non-interventional study of microcirculation dynamics in allogeneic hematopoietic cell transplantation survivors compared to controls: evidence of impaired microvascular response regardless of conventional cardiovascular risk factors.

Authors:  Eleni Gavriilaki; Panagiota Anyfanti; Achilles Anagnostopoulos; Eugenia Gkaliagkousi; Ioanna Sakellari; Ioannis Batsis; Panagiotis Dolgyras; Antonios Lazaridis; Barbara Nikolaidou; Nikolaos Koletsos; Maria Gavriilaki; Ippokratis Zarifis; Marianna Masmanidou; Zoi Bousiou; Anna Vardi; Stella Douma
Journal:  Bone Marrow Transplant       Date:  2021-10-13       Impact factor: 5.483

2.  A novel effective method for the assessment of microvascular function in male patients with coronary artery disease: a pilot study using laser speckle contrast imaging.

Authors:  J P Borges; G O Lopes; V Verri; M P Coelho; P M C Nascimento; D A Kopiler; E Tibirica
Journal:  Braz J Med Biol Res       Date:  2016-09-01       Impact factor: 2.590

3.  Non-contact incipient fault diagnosis method of fixed-axis gearbox based on CEEMDAN.

Authors:  S S Dhami; B S Pabla
Journal:  R Soc Open Sci       Date:  2017-08-23       Impact factor: 2.963

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.