Literature DB >> 25347870

Toward an anemia early detection device based on 50-μL whole blood sample.

Jaime Punter-Villagrasa, Joan Cid, Jordi Colomer-Farrarons, Ivón Rodríguez-Villarreal, Pere Ll Miribel-Catala.   

Abstract

A first approach to a portable and compact device for point-of-care (PoC) early instantaneous detection of anemia is described. This device works directly with whole blood samples relying on hematocrit analysis by means of impedance analysis. This device consists of a custom electronic instrumentation, postprocessing software and plug-and-play disposable sensor. The designed electronics are connected to a remote computer, which allows control of the instrumentation and results displaying with a user friendly software panel. The disposable sensor is based on a low-cost label-free three gold electrode commercial sensor for 50-μL volume samples. Forty-eight whole blood samples, randomly collected from hospitalized patients in Hospital Clínic, were used to validate the device capability for anemia detection. Whole blood samples were distributed in two groups: 10 samples for system calibration, and 38 samples for system validation. To calibrate the device, a complete EIS experiment has been performed to get a full impedance spectrum analysis, defining an accurate frequency working range for hematocrit detection. Afterward, we developed a protocol for instant impedance detection to determine the system detection accuracy, sensitivity, and coefficient of variation. As a result, impedance variations between different samples have been detected with less than 2% accuracy error for both impedance magnitude and phase. A hematocrit detection algorithm, relying on impedance analysis, has been developed based on the previous studies. The response, effectiveness, and robustness of the portable PoC device to detect anemia have been proved with an accuracy error of 1.75% and a coefficient of variation of less than 5%.

Entities:  

Mesh:

Year:  2014        PMID: 25347870     DOI: 10.1109/TBME.2014.2364139

Source DB:  PubMed          Journal:  IEEE Trans Biomed Eng        ISSN: 0018-9294            Impact factor:   4.538


  3 in total

Review 1.  Emerging point-of-care technologies for anemia detection.

Authors:  Ran An; Yuning Huang; Yuncheng Man; Russell W Valentine; Erdem Kucukal; Utku Goreke; Zoe Sekyonda; Connie Piccone; Amma Owusu-Ansah; Sanjay Ahuja; Jane A Little; Umut A Gurkan
Journal:  Lab Chip       Date:  2021-05-18       Impact factor: 6.799

2.  An instantaneous low-cost point-of-care anemia detection device.

Authors:  Jaime Punter-Villagrasa; Joan Cid; Cristina Páez-Avilés; Ivón Rodríguez-Villarreal; Esteve Juanola-Feliu; Jordi Colomer-Farrarons; Pere Ll Miribel-Català
Journal:  Sensors (Basel)       Date:  2015-02-16       Impact factor: 3.576

3.  Evaluation of point-of-care testing device for anemia detection: A cross-sectional method comparison study from Thailand.

Authors:  Wittawat Chantkran; Pitipat Jamnarnwej; Pipat Sritanabutr; Pasra Arnutti
Journal:  J Clin Lab Anal       Date:  2021-08-24       Impact factor: 2.352

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.