Sonographic confirmation of intubation: comparison of 3 methods in a pig model.

Gavin Budhram1, David Murman2, Lucienne Lutfy2, Alison Sullivan2.   

Abstract

OBJECTIVES: Several recent studies have investigated methods to confirm endotracheal tube (ETT) placement with sonography, using diaphragmatic movement, lung sliding, and transtracheal visualization of the ETT. To our knowledge, no studies have directly compared these 3 methods. This study aimed to directly compare the test characteristics of these 3 methods to determine ETT placement. Additionally, we compared the time required to complete the sonographic examination and the performers' confidence in their findings.
METHODS: We conducted a prospective randomized single-blinded study. Twenty-five recently euthanized pigs were intubated either in the esophagus or trachea, for a total of 50 intubations. Each of the 3 sonographic methods of intubation confirmation was performed by sonographers of different skill levels. Sonographic findings, the time to findings, and confidence in findings were recorded.
RESULTS: A total of 150 sonographic examinations were performed. There were no significant differences in the sensitivity, specificity, positive predictive value, negative predictive value, or accuracy for correct ETT placement between the 3 methods of intubation confirmation. On average, the transtracheal and thoracic methods were faster (12.5 and 14.0 seconds, respectively) than the diaphragmatic method (21.0 seconds; P < .01). There were no significant differences in operator confidence between the confirmation methods.
CONCLUSIONS: All 3 methods for determining ETT placement had similar test characteristics. Transtracheal and thoracic sonography were faster than diaphragmatic sonography for determining ETT placement in pigs.
© 2014 by the American Institute of Ultrasound in Medicine.

Entities:  

Keywords:  confirmation; emergency ultrasound; esophageal; imaging; intubation; sonography

Mesh:

Year:  2014        PMID: 25336479     DOI: 10.7863/ultra.33.11.1925

Source DB:  PubMed          Journal:  J Ultrasound Med        ISSN: 0278-4297            Impact factor:   2.153


  2 in total

1.  Screening Characteristics of Bedside Ultrasonography in Confirming Endotracheal Tube Placement; a Diagnostic Accuracy Study.

Authors:  Hamid Zamani Moghadam; Mohamad Davood Sharifi; Hasan Rajabi; Mojtaba Mousavi Bazaz; Ali Alamdaran; Niazmohammad Jafari; Seyed Amir Masoud Hashemian; Morteza Talebi Deloei
Journal:  Emerg (Tehran)       Date:  2017-01-09

2.  Changes of diaphragmatic excursion and lung compliance during major laparoscopic pelvic surgery: A prospective observational study.

Authors:  Kyungmi Kim; Dong-Min Jang; Jong-Yeon Park; Hwanhee Yoo; Hong Soon Kim; Woo-Jong Choi
Journal:  PLoS One       Date:  2018-11-29       Impact factor: 3.240

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.